How ALMA keeps separated antennas in step

ALMA compares voltages from separated antennas after accounting for when the same wave reaches each one. The relationship between those voltages carries detail that an individual antenna cannot resolve. Preserving it is the first task of the telescope, before any image appears.

Sandbox Physics ·

Bringing the signal into the electronics

Each dish directs incoming radiation into a receiver. Its electrical output contains the astronomical signal and noise from the receiving system. Cold receiver components reduce part of that noise. The signal must also retain its timing relative to the other antennas.

A mixer multiplies the incoming signal by a stable reference oscillation called a local oscillator. This produces a lower difference frequency that the electronics can filter and digitise. The wave’s phase, its position within an oscillation, survives relative to that reference. ALMA distributes a common reference over optical fibre and corrects changes in the fibre path that would disturb the relative phase.

Sources: [2][3][4]

Comparing two antennas

A wave generally reaches two separated antennas at different times. Their separation vector, called a baseline, determines this geometric delay together with the source direction. After compensating the delay for the chosen pointing, a correlator multiplies the voltage streams and averages. A second comparison, offset by a quarter-cycle, supplies the other part of a complex correlation. The result is a visibility with an amplitude and a phase.

Each baseline samples a particular scale and direction of variation in sky brightness. Other baselines add other samples; Earth’s rotation changes the projected baselines too. Long separations reveal finer structure. Short ones measure broader structure, within the field accepted by the individual dishes.

Sources: [6][5][1]

The atmosphere changes the travel time

Air adds an electrical path delay that can differ above the antennas. A small path change matters more at shorter wavelengths because it shifts the wave through a larger fraction of a cycle.

If phase wanders during an average, parts of the correlated signal cancel. ALMA measures sky brightness near the 183 GHz water-vapour line and uses an atmospheric model to infer the changing wet path. Clouds and the dry component of the atmosphere leave residual errors, so observations of calibration sources are still needed.

Δϕ=2π ΔLλ\Delta\phi=\frac{2\pi\,\Delta L}{\lambda}
ΔL\Delta L is the extra path difference, λ\lambda the observing wavelength and Δϕ\Delta\phi the resulting phase difference in radians. An extra wavelength shifts the phase by one complete turn.

Sources: [6][7]

Measuring the receiving system as well as the sky

The electronics change amplitude and phase across the observing band. Calibration sources with known properties help measure those changes. Loads at known temperatures help determine receiver response and noise. These reference measurements have uncertainties, and their transfer to a target depends on how well they follow changes in time and direction.

Calibrated visibilities retain their antenna pairs, frequencies, times and uncertainty information. A phase correction applied after averaging cannot restore all the coherence already lost within that average. Integration length and calibration cadence therefore affect what information reaches the image.

Sources: [3][7][1]

An image also reflects what was not sampled

An array measures a finite set of spatial patterns. Imaging combines them with explicit assumptions about the missing information. Several images can explain the measurements, so an important check is to predict the visibilities of a proposed image and compare them with the observed ones.

Very extended emission needs short baselines and, in some cases, single-dish total-power measurements. ALMA’s compact array and total-power antennas supply that information. Fine angular resolution and a complete measurement of broad structure require different parts of the observing system.

Sources: [1]

Sources and further reading

  1. ALMA Science Portal — ALMA Basics

    Read on 14 November 2026: Interferometry, Field of view and Imaging of extended structures. Used for visibility, primary-beam and short-spacing principles, not cycle specifications or performance figures.

  2. ALMA Observatory — Receivers

    Read on 14 November 2026: cryogenic Front End paragraphs and Back End digitisation/fibre paragraphs. Band deployment and superlative performance statements are not used.

  3. Hunter & Napier — Antennas and Receivers in Radio Interferometry (2016)

    Read on 14 November 2026: arXiv v1 sections 3.2.2 on mixing, 3.4.1 on phase locking, and the two-load calibration discussion in section 3.6. The 2016 hardware tables are not treated as current specifications.

  4. NRAO Central Development Laboratory — Photonic Reference

    Read on 14 November 2026: opening text and the reference-synthesis/round-trip phase-correction bullets. No stability record is quoted.

  5. ALMA Observatory — Correlator

    Read on 14 November 2026: opening Main Array Correlator paragraphs on antenna-pair comparison and filtering. Processing rates, component counts and rankings are not used.

  6. NRAO Essential Radio Astronomy — Chapter 3

    Read on 14 November 2026: sections 3.6.4 and 3.7.1, plus the opening of 3.7.2, equations 3.172–3.186, on mixing, delay, multiplication/averaging, quadrature correlation and complex visibility.

  7. Nikolic et al. — Phase Correction for ALMA with 183 GHz Water Vapour Radiometers

    Read on 14 November 2026: abstract, sections 1.2–1.4 and 4, and the closing cloud/dry-air residual discussion in the accessible manuscript. Used for decorrelation, radiometric path inference and its limits; test-performance figures are not quoted.

Keep reading

What this page links to directly

See this series on the content map →

How physics instruments measure · Reading path

How physics instruments measure

  1. ArticleHow a vernier reads between millimetres
  2. ArticleAir helps hold up the object on a balance
  3. ArticleHow Cavendish Measured the Attraction Between Spheres
  4. ArticleWhich pressure does a liquid column measure?
  5. ArticleThe cup absorbs heat too
  6. ArticleRotational rheometers need both torque and speed
  7. ArticleWhy the air beyond a pipe changes its resonance
  8. ArticleHow a seismometer reads the ground through motion inside its case
  9. ArticleWhy does a meter change the circuit?
  10. ArticleHow a null detector reveals a resistance
  11. ArticleWhy a capacitor can behave like an inductor
  12. ArticleWhere does the slow wave on an oscilloscope come from?
  13. ArticleHow a lock-in amplifier finds a signal buried in noise
  14. ArticleWhere a small peak in a spectrum can come from
  15. ArticleHow a network analyzer separates the cable from the device
  16. ArticleWhen a slower quartz crystal can measure added mass
  17. ArticleHow an echelle spectrograph gives overlapping colors a second direction
  18. ArticleHow total brightness reveals many infrared colors
  19. ArticleMeasuring a Solution’s Concentration with Light
  20. ArticleHow an ellipsometer reads thin-film thickness from reflected light
  21. ArticleHow a polarimeter reveals mixed polarization
  22. ArticleHow individual photons reveal a fluorescence lifetime
  23. ArticleBrillouin Microscopy Listens to Sound with Light
  24. ArticleHow a white sphere compares a lamp’s total output
  25. ArticleHow powder rings reveal atomic spacing
  26. ArticleHow Small-Angle X-ray Scattering Reads a Particle Halo
  27. ArticleWhy X-ray fluorescence depends on sample thickness
  28. ArticleWhy an AFM makes a bump look wider
  29. ArticleHow a small indentation separates hardness from elasticity
  30. ArticleHow Differential Scanning Calorimetry Reads a Melting Peak
  31. ArticleHow thermogravimetry separates mass loss from the gas around it
  32. ArticleHow a diamond anvil cell reads pressure in ruby light
  33. ArticleHow diamond fluorescence reveals a magnetic-field direction
  34. ArticleReading a magnetic field in the rhythm of atoms
  35. ArticleKeeping a laser in time with atoms
  36. ArticleWhy a Kibble balance needs two experiments
  37. ArticleHow a dilution refrigerator keeps carrying heat away
  38. ArticleWhy a bigger vacuum pump may barely help the sample
  39. ArticleHow microwaves read a superconducting qubit
  40. ArticleHow current leaves a voltage across a thin sheet
  41. ArticleHow an ion flight becomes a mass spectrum
  42. ArticleHow four straight rods select ion mass
  43. ArticleHow a rapidly reversing field can hold ions
  44. ArticleHow a cyclotron keeps a proton on the accelerating beat
  45. ArticleWhy the drift tubes in an RF linac get longer
  46. ArticleThe directions hidden inside a small beam spot
  47. ArticleHow defocusing magnets help a beam stay in a ring
  48. ArticleWhy a collider cannot keep every collision
  49. ArticleGetting synchrotron light onto a sample
  50. ArticleHow a free-electron laser gathers electrons into a brighter beam
  51. ArticleFollowing energy exchange with neutron flight times
  52. ArticleHow a tokamak holds heat and measures where it goes
  53. ArticleWhy stellarator coils bend in three dimensions
  54. ArticleHow NIF turns a laser pulse into an implosion
  55. ArticleHow ELI brings an intense pulse to a target
  56. ArticleWhy a xenon detector needs liquid and gas
  57. ArticleHow LIGO measures a gravitational wave with mirrors that move
  58. ArticleHow delayed laser records let LISA measure gravitational waves
  59. ArticleHow FAST brings faint radio signals into focus
  60. You are hereHow ALMA keeps separated antennas in step
  61. ArticleHow SKA-Low steers a beam without moving its antennas
  62. ArticleHow EHT connects telescopes with clocks and hard drives
  63. ArticleHow Webb separates a faint spectrum from infrared background
  64. ArticleHow LHAASO finds an incoming direction from ground particles
1 more group

Other articles that use the same experiments

Each experiment from this article that another series also uses, followed by the articles there.

  1. LabStellar Interferometry and Sparse Imaging
  2. ArticleHow scattered telescopes make an image
  3. ArticleFrom wave delay to complex visibility
  4. ArticleEarth rotation and closure phase
  5. ArticleDirty beams and nonunique images
  6. ArticleFit a real EHT closure triangle
  7. ArticleRead EHT imaging and dynamic priors
  8. ArticleHow Ryle built a large radio telescope from smaller ones
Something broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy