Skip to main content
Sandbox Physics
How physics instruments measure

How delayed laser records let LISA measure gravitational waves

LISA will compare laser records from three distant spacecraft at carefully chosen delays. The same laser fluctuation appears in several measurements, so matching its emission history allows it to cancel. This time-delay interferometry also filters the gravitational-wave signal, leaving a response that must be understood and calibrated.

Sandbox Physics ·

Small falling masses provide the reference

The planned LISA observatory has three spacecraft separated by about 2.5 million kilometres. Their triangle changes slowly as it orbits the Sun. Small bodies inside the spacecraft, called test masses, provide references close to free fall. Laser measurements connect these widely separated references.

Sunlight pushes the spacecraft, and charging or temperature changes can disturb a measurement. The spacecraft shelter the masses and use tiny thrusters to follow them. The housing provides protection and instrument support while limiting forces on the references. Residual forces still contribute noise.

Sources: [1][2][3]

Each receiver compares incoming light with its own laser

Light takes several seconds to cross an arm. At the receiver it is weak, so it is combined with a local laser. Slightly different optical frequencies produce a beat in detected power, much as two nearby musical pitches rise and fall in loudness together. A phasemeter tracks the beat’s phase and saves it with local timestamps.

The other spacecraft has its own laser and receiver. Combining the two one-way phase records with the correct travel delay gives information equivalent to a round-trip measurement. The distant laser provides fresh light for the return link. The combined phase record supplies the round-trip information.

Sources: [5][3]

Unequal arms compare different parts of the laser’s history

A laser’s frequency fluctuates. Equal paths deliver the same fluctuation at the same time, allowing it to cancel in a comparison. Unequal arms instead compare the laser at different emission times. Simply subtracting the returning measurements leaves a large residual.

Saved measurements make another comparison possible. For fixed unequal arms, delay the first round-trip record by the second arm’s round-trip time, and the second record by the first arm’s time. An appropriate difference then pairs laser terms from the same emission history. This is the principle of time-delay interferometry, or TDI.

X(t)=ra(t)−ra(t−Tb)−rb(t)+rb(t−Ta)\begin{aligned}X(t)={}&r_a(t)-r_a(t-T_b)\\&-r_b(t)+r_b(t-T_a)\end{aligned}
The two r records are round-trip phase measurements; the two T values are their fixed round-trip travel times. The argument t is reception time in a common representation. These four terms form a simplified first-generation TDI channel. One-way measurements are first combined into the round-trip records used here.

Sources: [4][3]

Timestamps and delays must refer to the same events

The spacecraft clocks have their own readings. Matching timestamp numbers does not identify matching physical events. Ranging, clock comparisons and electronic calibration establish which times to combine. A calculation can use a common time coordinate or local clock representations, provided the delays and time mappings are treated consistently.

A required delay usually falls between samples. The recorded bandwidth and interpolation method determine how that intermediate value can be reconstructed. Known phase or frequency excitations and comparisons at different interpolation accuracy test processing residuals. The result must show a gap wherever a record boundary or missing segment leaves too few samples.

Sources: [7][6][5]

The surviving signal has its own response

Laser fluctuations repeat across several measurements. A gravitational wave acts along different directions and at different times on the optical paths. The delayed combination can therefore cancel laser terms while retaining a gravitational-wave response. It also changes signal amplitude and phase. Some directions or frequencies have little response, or none, so a single conversion constant cannot turn every output into an arbitrary wave’s strain.

The fixed-arm example explains the cancellation. When arm lengths change, applying one delay and then another generally differs from applying them in reverse. Different combinations are needed for the changing constellation. Interpreting an output requires its geometry, delay approximation, receiver noise, residual acceleration and calibration uncertainty.

LISA is still being developed. Its eventual observations will pass through this measurement chain before further scientific analysis. The constellation, optical receivers and timing relationships together connect the delivered data to changes in spacetime.

Sources: [8][4][7]

Sources and further reading

  1. ESA · LISA mission

    Read 14 November 2026: the current ESA mission/launch sections and the dates/status of construction news. Uses the future mission role, not forecast event counts or performance. The original entry redirects to ESA’s new site.

  2. ESA · LISA factsheet

    Read 14 November 2026: Spacecraft and orbit on the triangular formation, approximately 2.5-million-kilometre spacing, floating test masses and laser measurements. The page’s older construction tense is not current status; event-count and sensitivity forecasts are not used.

  3. LISA Consortium · Questions about LISA Technologies

    Read 14 November 2026: the TDI, pointing and key-features answers on individual links, travel times, ranging and spacecraft that shield/follow test masses. Internally inconsistent arm-variation and precision figures in this FAQ are not adopted.

  4. Tinto & Dhurandhar · Time-Delay Interferometry (2014)

    Read 14 November 2026: the 2014 version, section 4.2 equations (22)–(25), section 5.1 equations (54)–(59), and selected fractional-delay passages in section 7. The article uses fixed unequal arms. A later review exists; neither a complete reading nor second-generation implementation is claimed. Rights and permissions states CC BY 4.0.

  5. Shaddock et al. · Post-processed time-delay interferometry for LISA (2004)

    Read 14 November 2026: v1 PDF pages 2–4, sections I–II, on stored phase samples, finite bandwidth and fractional-delay filtering, including the normalized sinc definition. Uses the principle, not the older five-million-kilometre design, sampling rate, error target or achieved performance.

  6. Hartwig et al. · Time delay interferometry without clock synchronisation (2022)

    Read 14 November 2026: v2 abstract, introduction and opening of section II, PDF pages 1–2, on coordinate/proper/clock times and the simplified three-laser model. Used to avoid claiming that prior synchronization is mandatory. The complete local-time algorithm and numerical experiment are not reproduced.

  7. Cornish & Rubbo · The LISA Response Function (2003)

    Read 14 November 2026: v4 sections I–II, equations (4)–(19), PDF pages 1–2, on path integration, propagation direction and finite travel time. Uses the geometric response, not the older design arm/frequency numbers; the full orbital response has not been recomputed.

Keep reading

What this page links to directly

See this series on the content map →

How physics instruments measure · Reading path

How physics instruments measure

  1. ArticleHow a vernier reads between millimetres
  2. ArticleAir helps hold up the object on a balance
  3. ArticleHow Cavendish Measured the Attraction Between Spheres
  4. ArticleWhich pressure does a liquid column measure?
  5. ArticleThe cup absorbs heat too
  6. ArticleRotational rheometers need both torque and speed
  7. ArticleWhy the air beyond a pipe changes its resonance
  8. ArticleHow a seismometer reads the ground through motion inside its case
  9. ArticleWhy does a meter change the circuit?
  10. ArticleHow a null detector reveals a resistance
  11. ArticleWhy a capacitor can behave like an inductor
  12. ArticleWhere does the slow wave on an oscilloscope come from?
  13. ArticleHow a lock-in amplifier finds a signal buried in noise
  14. ArticleWhere a small peak in a spectrum can come from
  15. ArticleHow a network analyzer separates the cable from the device
  16. ArticleWhen a slower quartz crystal can measure added mass
  17. ArticleHow an echelle spectrograph gives overlapping colors a second direction
  18. ArticleHow total brightness reveals many infrared colors
  19. ArticleMeasuring a Solution’s Concentration with Light
  20. ArticleHow an ellipsometer reads thin-film thickness from reflected light
  21. ArticleHow a polarimeter reveals mixed polarization
  22. ArticleHow individual photons reveal a fluorescence lifetime
  23. ArticleBrillouin Microscopy Listens to Sound with Light
  24. ArticleHow a white sphere compares a lamp’s total output
  25. ArticleHow powder rings reveal atomic spacing
  26. ArticleHow Small-Angle X-ray Scattering Reads a Particle Halo
  27. ArticleWhy X-ray fluorescence depends on sample thickness
  28. ArticleWhy an AFM makes a bump look wider
  29. ArticleHow a small indentation separates hardness from elasticity
  30. ArticleHow Differential Scanning Calorimetry Reads a Melting Peak
  31. ArticleHow thermogravimetry separates mass loss from the gas around it
  32. ArticleHow a diamond anvil cell reads pressure in ruby light
  33. ArticleHow diamond fluorescence reveals a magnetic-field direction
  34. ArticleReading a magnetic field in the rhythm of atoms
  35. ArticleKeeping a laser in time with atoms
  36. ArticleWhy a Kibble balance needs two experiments
  37. ArticleHow a dilution refrigerator keeps carrying heat away
  38. ArticleWhy a bigger vacuum pump may barely help the sample
  39. ArticleHow microwaves read a superconducting qubit
  40. ArticleHow current leaves a voltage across a thin sheet
  41. ArticleHow an ion flight becomes a mass spectrum
  42. ArticleHow four straight rods select ion mass
  43. ArticleHow a rapidly reversing field can hold ions
  44. ArticleHow a cyclotron keeps a proton on the accelerating beat
  45. ArticleWhy the drift tubes in an RF linac get longer
  46. ArticleThe directions hidden inside a small beam spot
  47. ArticleHow defocusing magnets help a beam stay in a ring
  48. ArticleWhy a collider cannot keep every collision
  49. ArticleGetting synchrotron light onto a sample
  50. ArticleHow a free-electron laser gathers electrons into a brighter beam
  51. ArticleFollowing energy exchange with neutron flight times
  52. ArticleHow a tokamak holds heat and measures where it goes
  53. ArticleWhy stellarator coils bend in three dimensions
  54. ArticleHow NIF turns a laser pulse into an implosion
  55. ArticleHow ELI brings an intense pulse to a target
  56. ArticleWhy a xenon detector needs liquid and gas
  57. ArticleHow LIGO measures a gravitational wave with mirrors that move
  58. You are hereHow delayed laser records let LISA measure gravitational waves
  59. ArticleHow FAST brings faint radio signals into focus
  60. ArticleHow ALMA keeps separated antennas in step
  61. ArticleHow SKA-Low steers a beam without moving its antennas
  62. ArticleHow EHT connects telescopes with clocks and hard drives
  63. ArticleHow Webb separates a faint spectrum from infrared background
  64. ArticleHow LHAASO finds an incoming direction from ground particles
Something broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy