How LHAASO finds an incoming direction from ground particles

LHAASO samples particles from an air shower across a ground array. Their arrival times reveal the incoming direction, and their signal distribution helps locate the shower centre. Different particle components provide evidence about whether the primary was a high-energy photon or a cosmic-ray nucleus. Detector calibration connects these clues to a measurement.

Sandbox Physics ·

One primary produces many secondaries

A high-energy particle entering the atmosphere can start a chain of interactions. New particles continue the cascade, spreading along its path and sideways. By ground level, the original particle is usually gone. Detectors sample some of its secondaries.

Photon showers are predominantly electromagnetic, with electrons, positrons and photons. Nuclear interactions also produce unstable particles, some of which decay into muons.

Muons are charged particles that can penetrate substantial material. Shower populations fluctuate even for similar primaries.

Sources: [1]

Different detectors sample different components

KM2A surface scintillators flash when charged particles cross them. Photomultipliers convert the light into electrical signals, and electronics measure arrival time and charge. Covered detectors suppress much of the electron and photon contribution and preferentially measure penetrating muons.

LHAASO also uses water-Cherenkov detectors to sample ground particles and wide-field Cherenkov telescopes to view shower light in the atmosphere. These methods have different receiving areas, thresholds and timing responses.

Sources: [2][5]

Using which side arrived first

A tilted shower front reaches one side of an array before the other. Given the station coordinates, a fit finds the propagation direction that explains the times. A plane is the simplest front model. More detailed reconstruction accounts for curvature and late particles.

The shower core is where its axis meets the ground. Particle density generally falls away from it. If the core is outside the array, sampling only the edge can mislead the fit. Core location also affects curved-front corrections, linking the timing and spatial signal measurements.

ti=t0+(ri−r0)⋅n^ct_i=t_0+\frac{(\boldsymbol r_i-\boldsymbol r_0)\cdot\hat{\boldsymbol n}}{c}
This is a plane-front approximation. ri\boldsymbol r_i is a station position, n^\hat{\boldsymbol n} points along shower propagation, and t0t_0 is the time the front crosses reference position r0\boldsymbol r_0. cc is the speed of light. The incoming sky direction is opposite to propagation.

Sources: [3][4]

Measuring channel delays before fitting a direction

A recorded time includes sensor, cable and electronic delays. A shared timing network aligns clocks, but channel-response offsets still require calibration. A systematic delay on one side of the array can imitate a tilted shower.

Charge calibration makes signals comparable and tracks gain changes and bad channels. Particles below threshold, in gaps or outside the array are unrecorded. Estimating primary energy from ground signals therefore needs a calibrated shower-and-detector response model.

Sources: [4][2][3]

Muon content supplies statistical evidence

A shower with few muons relative to its electromagnetic signal is generally more photon-like. The comparison depends on shower size, core position and detection efficiency. Photon and nuclear-shower distributions overlap, and a finite array can miss muons that were present.

Detecting no muons can therefore contribute to classification without uniquely identifying a photon. Direction, energy and primary type have different uncertainties. Keeping coordinates, times, charges, triggers and bad-channel information makes those inferences reproducible.

Sources: [1][3]

Sources and further reading

  1. Particle Data Group — Cosmic Rays (2024)

    Read on 14 November 2026: opening section 30.2.2 and text around figure 30.6 on electromagnetic, hadronic and muonic components, photon-induced hadronic branches and unobserved energy. No flux or composition record is used.

  2. Ma et al. — LHAASO Instruments and Detector Technology (2022)

    Read on 14 November 2026: KM2A electromagnetic/muon units, WCDA/WFCTA roles, and White Rabbit/DAQ/trigger passages. Historical design counts, sensitivity figures and background-free goals are not adopted.

  3. LHAASO Collaboration — Observation of the Crab Nebula with LHAASO-KM2A: a performance study (2021)

    Read on 14 November 2026: detector response/calibration, Event Reconstruction core and conical-front passages, and overlap in gamma/hadron discrimination. Measured energies, sensitivity and discovery claims are not used.

  4. Lv et al. — Timing Calibration of the LHAASO-KM2A Electromagnetic Particle Detectors (ICRC2017)

    Read on 14 November 2026: abstract, sections 1–2 and opening timing-offset method. Used for the effect of channel offsets and their calibration, not prototype precision or historical layouts as current specifications.

  5. Prototype of Readout Electronics for the LHAASO KM2A Electromagnetic Particle Detectors (2016)

    Read on 14 November 2026: public abstract only, used solely for the front-end charge/arrival-time measurement role. No complete-circuit review or prototype-performance adoption is claimed.

Keep reading

What this page links to directly

See this series on the content map →

How physics instruments measure · Reading path

How physics instruments measure

  1. ArticleHow a vernier reads between millimetres
  2. ArticleAir helps hold up the object on a balance
  3. ArticleHow Cavendish Measured the Attraction Between Spheres
  4. ArticleWhich pressure does a liquid column measure?
  5. ArticleThe cup absorbs heat too
  6. ArticleRotational rheometers need both torque and speed
  7. ArticleWhy the air beyond a pipe changes its resonance
  8. ArticleHow a seismometer reads the ground through motion inside its case
  9. ArticleWhy does a meter change the circuit?
  10. ArticleHow a null detector reveals a resistance
  11. ArticleWhy a capacitor can behave like an inductor
  12. ArticleWhere does the slow wave on an oscilloscope come from?
  13. ArticleHow a lock-in amplifier finds a signal buried in noise
  14. ArticleWhere a small peak in a spectrum can come from
  15. ArticleHow a network analyzer separates the cable from the device
  16. ArticleWhen a slower quartz crystal can measure added mass
  17. ArticleHow an echelle spectrograph gives overlapping colors a second direction
  18. ArticleHow total brightness reveals many infrared colors
  19. ArticleMeasuring a Solution’s Concentration with Light
  20. ArticleHow an ellipsometer reads thin-film thickness from reflected light
  21. ArticleHow a polarimeter reveals mixed polarization
  22. ArticleHow individual photons reveal a fluorescence lifetime
  23. ArticleBrillouin Microscopy Listens to Sound with Light
  24. ArticleHow a white sphere compares a lamp’s total output
  25. ArticleHow powder rings reveal atomic spacing
  26. ArticleHow Small-Angle X-ray Scattering Reads a Particle Halo
  27. ArticleWhy X-ray fluorescence depends on sample thickness
  28. ArticleWhy an AFM makes a bump look wider
  29. ArticleHow a small indentation separates hardness from elasticity
  30. ArticleHow Differential Scanning Calorimetry Reads a Melting Peak
  31. ArticleHow thermogravimetry separates mass loss from the gas around it
  32. ArticleHow a diamond anvil cell reads pressure in ruby light
  33. ArticleHow diamond fluorescence reveals a magnetic-field direction
  34. ArticleReading a magnetic field in the rhythm of atoms
  35. ArticleKeeping a laser in time with atoms
  36. ArticleWhy a Kibble balance needs two experiments
  37. ArticleHow a dilution refrigerator keeps carrying heat away
  38. ArticleWhy a bigger vacuum pump may barely help the sample
  39. ArticleHow microwaves read a superconducting qubit
  40. ArticleHow current leaves a voltage across a thin sheet
  41. ArticleHow an ion flight becomes a mass spectrum
  42. ArticleHow four straight rods select ion mass
  43. ArticleHow a rapidly reversing field can hold ions
  44. ArticleHow a cyclotron keeps a proton on the accelerating beat
  45. ArticleWhy the drift tubes in an RF linac get longer
  46. ArticleThe directions hidden inside a small beam spot
  47. ArticleHow defocusing magnets help a beam stay in a ring
  48. ArticleWhy a collider cannot keep every collision
  49. ArticleGetting synchrotron light onto a sample
  50. ArticleHow a free-electron laser gathers electrons into a brighter beam
  51. ArticleFollowing energy exchange with neutron flight times
  52. ArticleHow a tokamak holds heat and measures where it goes
  53. ArticleWhy stellarator coils bend in three dimensions
  54. ArticleHow NIF turns a laser pulse into an implosion
  55. ArticleHow ELI brings an intense pulse to a target
  56. ArticleWhy a xenon detector needs liquid and gas
  57. ArticleHow LIGO measures a gravitational wave with mirrors that move
  58. ArticleHow delayed laser records let LISA measure gravitational waves
  59. ArticleHow FAST brings faint radio signals into focus
  60. ArticleHow ALMA keeps separated antennas in step
  61. ArticleHow SKA-Low steers a beam without moving its antennas
  62. ArticleHow EHT connects telescopes with clocks and hard drives
  63. ArticleHow Webb separates a faint spectrum from infrared background
  64. You are hereHow LHAASO finds an incoming direction from ground particles