How FAST brings faint radio signals into focus

FAST steers by reshaping part of its reflector and moving the receiver above it. The working surface brings waves from a chosen direction to a common focus. Its 500 m outer diameter describes the whole structure. The usual illuminated region is about 300 m across.

Sandbox Physics ·

The reflector and feed move together

A spherical bowl fits a large depression, but a broad spherical patch does not bring parallel incoming waves to one sharp focus. An ideal paraboloid gives waves from its chosen direction equal optical paths to the focus. FAST adjusts panel support points to approximate this working shape. Actuators below the surface pull on the supporting cable net.

Tracking changes the working patch and the location of its focus. The feed, a small receiving antenna in the suspended cabin, must follow. Cables provide the large movements; mechanisms inside the cabin refine the receiver position and orientation. Collecting area and receiver alignment work together. The larger bowl leaves room for the working patch to move, with usable illumination restricted near the observing limits.

Sources: [1][2]

A large dish has a directional response

Waves reflected across the illuminated area add together. At the intended direction their crests align; an offset introduces path differences and partial cancellation. The resulting directional sensitivity is the antenna beam.

This beam has weaker sidelobes around its main response. Illumination, panel errors and surrounding structures reshape them. At a fixed frequency, a larger effective illuminated area usually distinguishes closer directions, making pointing accuracy part of the measurement. Scanning a source much smaller than the beam, at a known position, helps locate the beam centre and measure its width.

Sources: [3][4][5]

Measuring power in fluctuating voltages

The feed turns radio waves into a voltage. Amplification, frequency separation and digitization produce stored observations. Each cell in the dynamic spectrum measures power within one frequency band and one sampling interval.

Sky emission, radiation entering from the ground and receiver electronics all contribute fluctuations. Their total noise power can be expressed as an equivalent system temperature. Averaging reduces random fluctuations under stable conditions. Gain drift can leave a different error.

σT≃TsysBτ\sigma_T\simeq\frac{T_{\mathrm{sys}}}{\sqrt{B\tau}}
For an ideal single total-power channel, TsysT_{\mathrm{sys}} represents total noise power, BB is effective bandwidth, τ\tau is averaging time and σT\sigma_T is the random readout fluctuation. Stable noise and gain are required. Longer averaging can also blur short pulses.

Sources: [4][6]

A reference noise signal measures the response

A calibrated noise signal can be switched into the receiving chain. Comparing its known contribution with the readout increase measures the response across frequency. The injected source needs its own calibration.

The 2020 FAST performance paper describes hot-load measurements and ON/OFF observations of the radio calibrator 3C286. These connect the internal noise reference and the response to a celestial source. An OFF position containing unwanted emission can contaminate that comparison.

Sources: [5]

Aligning the pulse across frequency

A pulsar appears to flash as its rotating radiation beam sweeps past Earth. Interstellar plasma delays the lower-frequency part of a pulse more than the higher-frequency part. Summing the band before correcting those delays spreads the pulse out.

Dedispersion compensates trial delays before adding the channels. A search tries different electron columns along the path. Shifting detected-power channels cannot recover every detail already averaged away within a channel. Channel responses, frequencies and sample times belong with the saved observations.

Sources: [7][6]

A repeating candidate must survive further checks

One weak pulse may be inconspicuous, while repeated pulses build a detectable rhythm. A period search separates a time series into repetition frequencies. Narrow pulses can spread their periodic signal over several related harmonics. The sampling clock converts sample number to seconds; an error in that scale shifts the inferred period.

Noise produces peaks too, and radio interference can repeat. More trials give more opportunities for a large accidental peak. Frequency structure, dispersion and follow-up observations help test a candidate. Preserving the observations and calibrations lets another reader search the same signal again.

Sources: [8][5]

Sources and further reading

  1. Nan et al. · The FAST Project (2011), arXiv v2

    Read on 14 November 2026: printed pp.8,12–14, §§3.2.1–3.2.2 and3.3.1–3.3.3 on active geometry, cable net and feed positioning. Historical design targets are not current performance claims.

  2. Jiang et al. · FAST: The Five-Hundred-Meter Aperture Spherical Radio Telescope (2023)

    Read on 14 November 2026: opening of §1 on the 500 m structure, 300 m illuminated paraboloid, cable positioning and cabin fine adjustment. No sensitivity record or discovery count is adopted.

  3. Dong & Han · Beam Patterns of FAST (2013)

    Read on 14 November 2026: abstract, §§1–2 and the opening of §3.1 on illumination, surfaces, surrounding structure and beam patterns. Its computed efficiencies are not reported as current measurements.

  4. NRAO · Essential Radio Astronomy, Chapter3

    Read public HTML on 14 November 2026:§3.3.1 Eq.3.97, the ideal radiometer/gain-drift passages in§§3.6.2–3.6.3, and the openings of§§3.6.4–3.6.5. No figures are copied.

  5. Jiang et al. · Fundamental Performance of FAST with the 19-beam Receiver (2020), v1

    Read on 14 November 2026:§II.1 noise injection/hot loads,§II.2.3 beam mapping,§II.3 ON/OFF and 3C286 calibration, and the opening/narrowband discussion of§IV.2. These historical measurements illustrate methods, not 2026 performance guarantees.

  6. FAST · 科学数据说明文档 v5

    Read all four pages on 14 November 2026, especially data types, channel/sample/gain settings and diode gates. The undated document is not treated as a current configuration or exact clock specification.

  7. NRAO · Essential Radio Astronomy, Chapter6

    Read on 14 November 2026: opening of §6.1 and§6.2 on rotating beams, Eqs.6.42–6.46, finite-band smearing and intensity versus baseband correction. No shortest-period or distance-accuracy record is adopted.

  8. Ransom, Eikenberry & Middleditch · Fourier Techniques (2002), v1

    Read on 14 November 2026:§§3.1–3.3 and§5.1 on noise normalization, periodic/harmonic response and independent trials in Eq.46. No significance formula is transplanted to an unspecified noise model.

Keep reading

What this page links to directly

See this series on the content map →

How physics instruments measure · Reading path

How physics instruments measure

  1. ArticleHow a vernier reads between millimetres
  2. ArticleAir helps hold up the object on a balance
  3. ArticleHow Cavendish Measured the Attraction Between Spheres
  4. ArticleWhich pressure does a liquid column measure?
  5. ArticleThe cup absorbs heat too
  6. ArticleRotational rheometers need both torque and speed
  7. ArticleWhy the air beyond a pipe changes its resonance
  8. ArticleHow a seismometer reads the ground through motion inside its case
  9. ArticleWhy does a meter change the circuit?
  10. ArticleHow a null detector reveals a resistance
  11. ArticleWhy a capacitor can behave like an inductor
  12. ArticleWhere does the slow wave on an oscilloscope come from?
  13. ArticleHow a lock-in amplifier finds a signal buried in noise
  14. ArticleWhere a small peak in a spectrum can come from
  15. ArticleHow a network analyzer separates the cable from the device
  16. ArticleWhen a slower quartz crystal can measure added mass
  17. ArticleHow an echelle spectrograph gives overlapping colors a second direction
  18. ArticleHow total brightness reveals many infrared colors
  19. ArticleMeasuring a Solution’s Concentration with Light
  20. ArticleHow an ellipsometer reads thin-film thickness from reflected light
  21. ArticleHow a polarimeter reveals mixed polarization
  22. ArticleHow individual photons reveal a fluorescence lifetime
  23. ArticleBrillouin Microscopy Listens to Sound with Light
  24. ArticleHow a white sphere compares a lamp’s total output
  25. ArticleHow powder rings reveal atomic spacing
  26. ArticleHow Small-Angle X-ray Scattering Reads a Particle Halo
  27. ArticleWhy X-ray fluorescence depends on sample thickness
  28. ArticleWhy an AFM makes a bump look wider
  29. ArticleHow a small indentation separates hardness from elasticity
  30. ArticleHow Differential Scanning Calorimetry Reads a Melting Peak
  31. ArticleHow thermogravimetry separates mass loss from the gas around it
  32. ArticleHow a diamond anvil cell reads pressure in ruby light
  33. ArticleHow diamond fluorescence reveals a magnetic-field direction
  34. ArticleReading a magnetic field in the rhythm of atoms
  35. ArticleKeeping a laser in time with atoms
  36. ArticleWhy a Kibble balance needs two experiments
  37. ArticleHow a dilution refrigerator keeps carrying heat away
  38. ArticleWhy a bigger vacuum pump may barely help the sample
  39. ArticleHow microwaves read a superconducting qubit
  40. ArticleHow current leaves a voltage across a thin sheet
  41. ArticleHow an ion flight becomes a mass spectrum
  42. ArticleHow four straight rods select ion mass
  43. ArticleHow a rapidly reversing field can hold ions
  44. ArticleHow a cyclotron keeps a proton on the accelerating beat
  45. ArticleWhy the drift tubes in an RF linac get longer
  46. ArticleThe directions hidden inside a small beam spot
  47. ArticleHow defocusing magnets help a beam stay in a ring
  48. ArticleWhy a collider cannot keep every collision
  49. ArticleGetting synchrotron light onto a sample
  50. ArticleHow a free-electron laser gathers electrons into a brighter beam
  51. ArticleFollowing energy exchange with neutron flight times
  52. ArticleHow a tokamak holds heat and measures where it goes
  53. ArticleWhy stellarator coils bend in three dimensions
  54. ArticleHow NIF turns a laser pulse into an implosion
  55. ArticleHow ELI brings an intense pulse to a target
  56. ArticleWhy a xenon detector needs liquid and gas
  57. ArticleHow LIGO measures a gravitational wave with mirrors that move
  58. ArticleHow delayed laser records let LISA measure gravitational waves
  59. You are hereHow FAST brings faint radio signals into focus
  60. ArticleHow ALMA keeps separated antennas in step
  61. ArticleHow SKA-Low steers a beam without moving its antennas
  62. ArticleHow EHT connects telescopes with clocks and hard drives
  63. ArticleHow Webb separates a faint spectrum from infrared background
  64. ArticleHow LHAASO finds an incoming direction from ground particles
Something broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy