Skip to main content
Sandbox Physics

Optical Tweezers: Brownian Calibration

How does a bead’s thermal motion reveal the stiffness of an optical trap? A stiffer trap confines the bead to smaller thermal excursions and makes its displacement relax faster. At a known temperature, the displacement variance gives stiffness; the relaxation rate gives a second estimate when the fluid drag is known.

Record a bead’s position signal in a liquid, calculate its displacement spectrum and compare two stiffness estimates. Slow sampling and long exposure show where the calibration becomes unreliable.

Interactive modelOptical Tweezers: Brownian Calibration

Motion sets a force scale

Simulated measurements

Move a control or reset to start a fresh simulation.

Physical assumptions and sources

One harmonic transverse coordinate at a fixed known temperature. Stable axial trapping is assumed. Far-wall spherical Stokes drag, thermal white noise and known detector distance calibration are used. Exposure is numerically averaged along the physical trajectory. The PSD and both estimates use stored detector samples. There is no molecular force trace or optical-force field calculation. Cell and bead sizes are schematic. Motion and static focus translation use one fixed scene scale across presets, with the displayed magnification relative to bead size. Playback is slowed one thousand times. Moving the focus starts a new equilibrium record; no steering transient or optical-force field is inferred. The QPD signal remains displacement relative to the beam. Faint bead outlines show past recorded samples from the last 2.5 seconds of slowed playback; no extra trajectory is generated.

Jun et al. (2014) · calibration comparison
Sarshar et al. (2014) · displacement and spectral methods
Pérez-García et al. · finite detector exposure

Use thermal motion as a force calibration

BackgroundA dielectric bead trapped in water still receives random kicks from the fluid. Near the trap center, its restoring force acts like a spring.

Why it mattersThe amplitude and speed of the bead’s motion provide two ways to estimate stiffness. They depend on different calibration assumptions.

One-sentence intuition
Variance needs temperature and a distance scale; relaxation additionally needs a drag model.

Core mathematical model

Thermal displacement variance

⟨(x−xˉ)2⟩=kBTκ\langle(x-\bar x)^2\rangle=\frac{k_{\rm B}T}{\kappa}

This relation assumes equilibrium and a harmonic coordinate. The measured variance can be reduced by exposure averaging.

Drag and corner frequency

γ=6πηa,fc=κ2πγ\gamma=6\pi\eta a,\qquad f_c=\frac{\kappa}{2\pi\gamma}

The bead is spherical and far from walls in a Newtonian fluid. The frequency is in cycles per second.

One-sided displacement spectrum

Sx(f)=kBTπ2γ(f2+fc2)S_x(f)=\frac{k_{\rm B}T}{\pi^2\gamma(f^2+f_c^2)}

The continuous equilibrium reference integrates to the displacement variance. The plotted spectrum is a Welch estimate of the stored voltage samples after distance conversion.

Common difficulties

A good-looking spectrum may still give the wrong force

Typical misconceptionIf the spectrum is smooth, the stiffness must be accurate.

Better mental modelThe displacement calibration, fluid drag and detector bandwidth remain necessary. The simple decay estimator is withheld when the exposure or sampling cannot resolve its assumptions.

Run the experiment

  1. 01

    Record a resolved trajectory

    Use Resolve the corner, acquire a sample and analyze it.

    What to observe: The variance and short-lag decay estimate stiffness from the same position samples. Finite duration gives random differences.
  2. 02

    Reduce the bandwidth

    Acquire Slow sampling and Long exposure, then inspect the time series and spectrum.

    What to observe: Slow sampling hides the relaxation. Exposure averaging narrows the observed position distribution and biases variance stiffness upward.
  3. 03

    Use a wrong viscosity

    Acquire Wrong assumed drag and compare the two estimates.

    What to observe: Changing the viscosity assumed in analysis changes the decay-based stiffness. The variance estimate uses the known temperature instead.

Related experiments and articles

What this page links to directly

Membranes and vesicles · Reading path

From curvature to active membrane measurements

Articles on this path that use this experiment, followed by the other experiments they suggest.

  1. ArticleThe force needed to pull a membrane tube
  2. LabPulling a Membrane TetherTurn probe displacement into pulling force

Single-molecule forces and motors · Reading path

Thermal motion, molecular elasticity, unfolding and motors

Articles on this path that use this experiment, followed by the other experiments they suggest.

  1. ArticleHow a restless bead becomes a force meter

Probes and measurement · Reading path

Molecules, forces and ultrafast dynamics

Articles on this path that use this experiment, followed by the other experiments they suggest.

  1. ArticleOptical tweezers: from holding a bead to measuring force
  2. LabLaser Cooling & MOTCompare light forces on atoms
  3. LabCompound Optics WorkbenchWiden a laser beam with two lenses
1 more group

Stochastic thermodynamics · Reading path

From a trapped bead to free energy from irreversible pulls

Articles on this path that use this experiment, followed by the other experiments they suggest.

  1. ArticleHow far a trapped bead wanders at room temperature
  2. LabJarzynski Equality: Dragging a Trapped BeadWatch a cloud of beads in a still trap
Something broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy