A threshold scan, not an energy histogram
Each dot is an independent Poisson count divided by its dwell time. The vertical scale is logarithmic; bars use the square root of the count, not exact Poisson intervals. Click or use arrow keys to select a voltage.
Inspect the same counts near the endpoint
Observed minus fitted count rate over the last ten electronvolts. The gray curve is the massless prediction, with the other parameters refitted, minus the best fit. The pink curve is the generating reference, shown separately.
What the filter actually accepts
Normalized transmission against surplus energy, for the width used to acquire the data (blue) and the width assumed in the analysis (gold). Magnetic acceptance is folded into the source normalization. The curves show an ideal response, not reconstructed detector data.
How much can the mass change?
At each nonnegative mass squared, the source strength, a positive background and the endpoint offset are fitted again. Shading marks the range within a deviance rise of one; values above twelve are cut off. The coverage is not calibrated, and the plot claims no mass limit.
Conventions, approximations & primary sources
The reference endpoint is 18,575 eV. A positive deficit lies below it, and a positive endpoint offset raises the true endpoint. Electrons travel from left to right: source, analyzing plane, detector. Spacing, coils, flux lines, helix radii and detector segments are schematic. The cutaway and camera views all show the same apparatus. The paths only illustrate electrons that pass or are reflected; no electromagnetic field is tracked and no optical hits are sampled.
Across this narrow window, the electron momentum, energy and Fermi factor are held fixed. The remaining phase space uses one effective mass. An eight-point angular quadrature averages the analytic phase-space integral over an isotropic accepted cone, with a source-to-pinch field ratio of 0.6. The width is fixed at its value at the reference energy. Molecular final states, scattering in the source, Doppler broadening, voltage jitter, radiative corrections, field inhomogeneity and three distinct masses are left out. Because of these omissions, the results cannot be read as a precision KATRIN analysis.
Twenty-four thresholds run from thirty eV below to four eV above the reference endpoint. Dwell times are longer near the endpoint, and each threshold is a separate acquisition, not part of a nested count. A flat background is both generated and fitted; it is not subtracted as a known value. The endpoint calibration penalty stands for an assumed external measurement. The mass-squared scan covers the physical range from zero to nine square electronvolts; it gives no negative estimates and builds no calibrated confidence intervals.