A threshold scan, not an energy histogram
Each dot is an independent Poisson count divided by its dwell time. The vertical scale is logarithmic; bars use the square root of the count, not exact Poisson intervals. Click or use arrow keys to select a voltage.
Inspect the same counts near the endpoint
Observed minus fitted count rate in the last ten electronvolts. The gray curve is the refitted massless mean minus the best fit; pink is a separate generating reference.
What the filter actually accepts
Normalized transmission versus surplus energy for the acquired (blue) and assumed (gold) widths. Magnetic acceptance is absorbed into source normalization. This is an ideal response, not reconstructed detector data.
How much can the mass change?
Source strength, positive background and endpoint offset are refitted at each nonnegative mass squared. Shading marks a deviance rise of one; values above twelve are clipped. No coverage calibration or mass-limit claim.
Conventions, approximations & primary sources
Reference endpoint: 18,575 eV. Positive deficit is below it; positive endpoint offset raises the true endpoint. The electron travels left to right: source, analyzing plane, detector. Spacing, coils, flux lines, helical radii and detector segmentation are schematic. Cutaway and camera views expose the same apparatus. Paths only illustrate accepted and reflected electrons, without tracking an electromagnetic field or sampling optical hits.
The electron momentum, energy and Fermi factor are frozen across this narrow window. The remaining phase space uses one effective mass. An eight-point angular quadrature averages the analytic phase integral over an isotropic accepted cone with source-to-pinch field ratio 0.6. Width is frozen at the reference energy. Molecular final states, source scattering, Doppler broadening, voltage jitter, radiative corrections, field inhomogeneity and three distinct masses are omitted. These omissions preclude a precision KATRIN interpretation.
Twenty-four thresholds span thirty eV below to four eV above the reference endpoint. Dwell times grow near the endpoint; every threshold is a separate acquisition, not a nested count. A flat background is generated and fitted, not subtracted as known truth. The endpoint calibration penalty is an assumed external constraint. The physical mass-squared scan runs from zero to nine square electronvolts; negative estimates and calibrated confidence constructions are absent.