The number of dark particles per unit entropy obeys one equation: it falls at a rate set by annihilation minus inverse production, and nothing else changes it. Solved for a 100 GeV particle, it leaves Y∞=4.37×10−12 when the low-temperature cross-section is 2.136×10−26cm3s−1, which is today's measured density Ωh2=0.120. A two-line approximation gets within ten per cent of that, and it shows why the leftover is inversely proportional to the cross-section.
This chapter follows Equilibrium, expansion and the reaction race and uses its units and symbols. You need separable differential equations. The aims are to derive the equation for Y, solve it in its two regimes, convert the result into a density today and see why a computer needs an implicit method.
From particle number to particles per entropy
Count dark particles in a box that grows with the universe. Annihilation removes pairs at the rate ⟨σv⟩n2 per unit volume. Inverse production, bath particles colliding to make a pair, adds them at ⟨σv⟩neq2, because detailed balance requires the two to cancel in equilibrium. Dilution by the growing volume removes 3Hn. So
dtdn+3Hn=−⟨σv⟩(n2−neq2).
The Particle Data Group review prints the dilution term with a minus sign, dn/dt−3Hn. Particle Data Group, 2025, eq. 27.2 That sign would make the density grow without reactions. The plus sign used here is the one in D'Eramo, Fernandez and Profumo's eq. (15) and in Steigman and colleagues' eq. (1), and it follows from na3 being constant when nothing reacts. D'Eramo, Fernandez and Profumo, 2017, eq. 15
Now divide by s. Because sa3 is constant, d(n/s)/dt=(n˙+3Hn)/s. With T∝1/a the clock x=m/T obeys dx/dt=Hx, so
dlnxdY=−Hs⟨σv⟩(Y2−Yeq2).
In the radiation era s∝T3 and H∝T2, so s/H is a constant times 1/x. Write ⟨σv⟩=⟨σv⟩0F(x), where F→1 for slow particles. Then
For m=100GeV and ⟨σv⟩0=1.830×10−9GeV−2, λ=5.48×1012. This single number sets the whole problem. Note that λYeqF/x is exactly the Γ/H of the previous chapter.
Two regimes and a match
While Γ/H≫1, any excess Δ=Y−Yeq is destroyed almost at once. Setting dY/dlnx≃dYeq/dlnx gives a small lag, Δ≃x2/(2λF) for x≫1, so Y tracks equilibrium. At x=20 this is 4.2×10−11, 6 per cent of Yeq, as the full solution confirms.
Once Yeq has collapsed, drop it. The equation separates:
Y∞1=Y(xf)1+λ∫xf∞x2F(x)dx≃xfλ.
The last step uses F≃1 and Y(xf)≫Y∞. The matching point xf is fixed by asking where the lag Δ becomes comparable to Yeq. D'Eramo and colleagues set Δ=cYeq and obtain
exfxf1/2≃c+1c(c+2)2π5/2g∗35gmMPl⟨σv⟩0,
their eq. (C12) with a constant cross-section, where c is a number of order one. D'Eramo, Fernandez and Profumo, 2017, appendix C It follows from putting Yeq∝x3/2e−x into the condition that the lag reaches cYeq, and its constant is the same combination as λ times the prefactor of Yeq. Taking c=2−1 and iterating xf=ln(…)−21lnxf gives xf=21.7. This matching point sits earlier than the crossing Γ/H=1 at x=25.2; both are markers on a gradual process.
Worked example: the observed density
With xf=21.7 and λ=5.48×1012,
Y∞≃λxf=3.97×10−12.
To turn this into a density today, multiply by the mass and today's entropy density s0=2891cm−3, and divide by the critical density ρc/h2=1.054×10−5GeVcm−3:
Ωh2=ρc/h2mY∞s0=2.74×108GeVmY∞=0.109.
The numerical solution with a constant cross-section gives Y∞=4.11×10−12, so the matching estimate is 3.5 per cent low. With the Lab's F(x), which is 0.86 to 0.9 near freeze-out, annihilation is slightly weaker and the full answer is 4.37×10−12, or Ωh2=0.120. Planck measures 0.120±0.001. Planck Collaboration, 2018, abstract
Table 3.1 The full solution for the default Lab settings.
x
Y
Y/Yeq
Y/Y∞
10
5.69×10−6
1.00
1.3×106
20
7.14×10−10
1.06
163
25.2
3.42×10−11
6.76
7.83
50
7.81×10−12
4×1010
1.78
100
5.55×10−12
6×1031
1.27
208
4.81×10−12
2×1078
1.10
1000
4.37×10−12
1.00
Freeze-out is a process spread over a factor of ten in temperature. At Γ/H=1 there are still almost eight times the final number, and the last ten per cent disappears only by x≃200.
Why the leftover goes as one over the cross-section
Y∞≃xf/λ and λ∝⟨σv⟩0, while xf grows only logarithmically. A larger cross-section therefore leaves proportionally less. The saved scan gives Ωh2=2.23, 0.248 and 0.0273 at 10−27, 10−26 and 10−25cm3s−1: each decade costs a factor of nine rather than ten, because xf rises by about 2.3 per decade.
The required cross-section barely depends on the mass. In this model it is 1.92×10−26 for 10 GeV, 2.14×10−26 for 100 GeV and 2.36×10−26cm3s−1 for 1 TeV. The careful calculation of Steigman, Dasgupta and Beacom, with the full temperature dependence of g∗, gives 2.2×10−26 within about 5 per cent above 10 GeV for Ωh2=0.11; their fit, rescaled to 0.120, gives 1.98×10−26. Steigman, Dasgupta and Beacom, 2012, section II.D The Lab is 8 per cent higher, mostly because it holds g∗ fixed.
Why a computer needs an implicit step
At x=1, Γ/H=3.3×109: the equation tries to restore equilibrium a billion times per e-fold of cooling. An explicit step of any practical size overshoots and blows up. The saved model therefore uses the second-order backward differentiation formula in lnx. Each step asks for the new Y on both sides of the equation, which turns it into a quadratic,
aY2+Y−c=0,Y=1+1+4ac2c,
with a and c built from the step size, λF/x, the two previous values and Yeq2. This root is never negative and never loses precision by subtraction. The method guide Recompute a relic abundance with the saved scripts shows the explicit step failing and checks the implicit one against an independent time-domain solution.
On the default run, read Y∞ and the settling point. Then compare them with the last two rows of Table 3.1.
Move the cross-section slider up by exactly one in the logarithm. Predict Ωh2 from the factor-of-nine rule, then read it.
Switch the start to "From nothing". Explain why the final density does not change.
Exercises
Starting from dn/dt+3Hn=… and s∝T3, H∝T2, derive the equation for dY/dlnx and the expression for λ.
At x=25.2 the full solution has Y=3.42×10−11. Use ∫25.2∞F/x2dx=0.0374 to estimate Y∞, and explain the remaining difference from 4.37×10−12.
A particle of 1 TeV needs ⟨σv⟩0=2.36×10−26cm3s−1 in this model. Show from Y∞≃xf/λ why the value rises only slightly with mass.
Show that dn/dt−3Hn=0 would make na−3 constant, and explain why that cannot describe dilution.
AnswersShow the answer
Y˙=(n˙+3Hn)/s=−(⟨σv⟩s)(Y2−Yeq2). Divide by x˙=Hx: dY/dlnx=−(s⟨σv⟩/H)(Y2−Yeq2). With s=(2π2/45)g∗T3 and H=π2g∗/90T2/MPl, s/H=(2π10/15)g∗MPlT=(2π10/15)g∗mMPl/x.
1/Y∞=1/(3.42×10−11)+5.48×1012×0.0374=2.92×1010+2.05×1011, so Y∞=4.27×10−12, 2.4 per cent below the full value. Just after x=25.2 inverse production, the Yeq2 term, still adds a little.
λ∝m, so at fixed cross-section Y∞∝xf/m and Ωh2∝mY∞∝xf. The mass cancels except through xf, which grows by ln10≃2.3 per decade of mass. Keeping Ωh2 fixed then needs a cross-section larger by about xf(1TeV)/xf(100GeV)≃1.1.
d(na−3)/dt=a−3(n˙−3Hn)=0, so n∝a3 would grow as the volume grows. A fixed number of particles in a growing volume must have n∝a−3, which is n˙+3Hn=0.