After this chapter you can: Calculate a crystal spacing from an electron ring or X-ray peak and identify which calibration sets the result.
A diffraction peak gives a spacing once the wavelength and scattering angle are known. An area detector records counts at pixel positions. The analysis converts the positions to angles, locates peaks and uses Bragg's law. Calibration fixes the angular scale before the sample is interpreted.
2.1 The peak comes from waves adding in phase
Consider two parallel crystal planes separated by a perpendicular distance d. For elastic scattering, the incident and outgoing waves have the same wavelength λ. In the Bragg geometry both rays make an angle θ with the planes. The ray scattered from the deeper plane travels an extra dsinθ on the way in and again on the way out. Contributions from successive planes add in phase when
2dsinθ=nλ,n=1,2,…
The scattering angle α between the incident and outgoing beam directions is 2θ. For a first-order indexed peak,
d=2sin(α/2)λ.
The magnitude of momentum transfer divided by ℏ is q=4πsin(α/2)/λ. At a first-order peak, q=2π/d. This reciprocal relation explains why a smaller spacing sends the same wavelength to a larger scattering angle.
2.2 Counts become angles only after calibration
A powder contains crystallites in many orientations. Some grains satisfy the Bragg condition at each allowed angle. Their outgoing directions lie on a cone about the incident beam, so a detector perpendicular to the beam can cut out a ring. With sample-to-detector distance L and ring radius r measured from the direct-beam position, the geometry is
α=arctan(r/L).
At small angles the ring also gives a direct approximation for the spacing.
d≃rλL(r/L≪1).
The last approximation follows from tanα≃α and 2sin(α/2)≃α with angles in radians. Doubling the camera length doubles the radius at the same angle. A tilted panel requires the direction from the specimen to each pixel instead of this perpendicular-panel formula.
A calibration specimen with known spacings gives known peak angles at a stated wavelength. NIST's SRM 640g certificate gives the silicon lattice parameter a=0.5431109nm. Its table gives a calculated first peak at 2θ=28.441∘ for λ=0.15405929nm. The powder Lab uses the same lattice parameter to generate a synthetic standard at its own wavelength. It fits the detector distance and angle offsets from the standard image, then tests them with a separate exposure at another detector pose. The peak locations in the sample are inferred after that check.
2.3 A sequence of peaks tests the indexing
A cubic cell of side a has plane spacings dhkl=a/h2+k2+l2, where (hkl) indexes the plane family. Within a cell, atoms at different positions can scatter out of phase. In the model with identical atoms and a face-centered cubic lattice, the sum cancels for mixed odd and even indices. The first permitted families are (111), (200) and (220). With a different basis, a different sequence may be allowed. Even an allowed peak may be too weak, overlap its neighbors, or lie outside the detector.
The simulated X-ray sample in Figure 2.1 uses λ=0.071nm. Its first fitted peak is at 2θ≃17.69∘. For the (111) assignment, Bragg's law gives d111≃0.231nm and the cubic lattice parameter follows as a=3d111≃0.400nm. The other visible peaks test this assignment at spacings different from the first.
Integrated simulated record
Nominal scattering angle
Intensity (million photons per radian)0246152025303540
Scattering angle (degrees)
Figure 2.1 Simulated X-ray counts integrated by scattering angle after detector calibration. The separate Bragg markers use the nominal face-centered cubic cell with a=0.400nm. The first two observed peaks lie near 17.69∘ and 20.45∘.
2.4 Check a spacing two ways in the Labs
In Electron Diffraction & Reciprocal Space, choose Powder rings and Acquire counts. Keep the energy at 200keV. The relativistic de Broglie wavelength is about 2.508pm. Reduce Calibrated camera length from 600mm to 500mm and acquire again. The first indexed ring should shrink from about 3.77mm to 3.14mm. Convert both count-derived radii to angles and check that the spacing stays near 0.40nm. The simulation knows which ring to inspect and uses a specified camera length. At 300mm the neighboring powder rings overlap enough that the analysis withholds the spacing.
In Powder X-ray Diffractometer, start with One cubic powder. Use Keep exposure and note the first two angles under Peaks fitted in the observed angular profile. Switch to A shifted encoder zero, keep the new exposure, and compare the fitted angles as well as Withheld reference error. The raw counts are drawn at different detector poses relative to the encoder indications. The inferred lattice parameter in both cases should be near 0.400nm. The record includes the simulated dark, flat-field, standard and independent check frames. The reduction uses the saved pixel counts, wavelength and encoder readings to infer the sample cell.
2.5 Exercises
A first-order peak lies at 2θ=30∘ for λ=0.150nm. Find d.
Keeping the wavelength and order fixed, does a smaller spacing give a larger or smaller scattering angle?
A ring radius of 4mm is measured at L=400mm. Where should the ring appear at L=600mm?
At small angles, what happens to the inferred spacing if the camera length used in the calculation is too large by 5%?
Why does the powder pattern contain a ring, although one crystallite contributes in a small set of directions?
A (200) peak gives d200=0.200nm. What a and d111 does the cubic assignment predict?
Could (100) be the first line of the equal-scatterer face-centered cubic model? Explain.
A standard agrees with the expected peaks at the pose used in the fit. What extra check tests whether the geometry also transfers to another pose?
Exercise 1Show the answer
Use θ=15∘. Then d=0.150nm/(2sin15∘)≃0.290nm.
Exercise 2Show the answer
For a permitted reflection, sinθ=nλ/(2d) grows as d shrinks. The scattering angle increases.
Exercise 3Show the answer
At fixed scattering angle r/L stays constant. The radius scales to 6mm.
Exercise 4Show the answer
The estimate is too large by about 5%, since d≃λL/r is proportional to L at fixed radius and wavelength.
Exercise 5Show the answer
Different grains satisfy the same Bragg angle at different azimuths. Together they populate a cone, which makes a ring on a perpendicular detector.
Exercise 6Show the answer
a=2d200=0.400nm. This gives d111=a/3≃0.231nm.
Exercise 7Show the answer
No. (100) mixes odd and even indices, so the amplitudes of equal scatterers in the face-centered cell cancel.
Exercise 8Show the answer
Measure the known standard again at the other pose. Apply the original calibration without refitting it, then compare the recovered angles with the standard's predicted angles.
Test it in the Lab
Change one setting at a time, then compare what you see with the tables and answers in this chapter.