Skip to main content
Sandbox Physics
Volume 4 · Light, Imaging and Measurement

What sets the finest detail an optical system can resolve?

Track which diffraction orders a microscope admits, then compare a grating cutoff with point spread and contrast transfer.

Before you start: Chapter 2 and Chapter 3 on image planes, apertures and interference. Volume 2 Chapter 6 on Fourier modes.

After this chapter you can: Use wavelength and numerical aperture to estimate resolvable detail and interpret a contrast transfer curve.

A finite aperture spreads the light from a point into a spot. Nearby spots can overlap, and closely spaced stripes can lose contrast when the aperture blocks the diffracted light that carries their pattern. A resolution limit depends on what you are trying to distinguish, how the object is illuminated and how the image is sampled.

4.1 A circular aperture gives a point image finite width

The geometric focus of Chapter 2 locates the centre of a point image. Light admitted through the whole pupil also interferes around that centre. A clear, uniformly filled circular pupil creates a bright central disk with weaker rings around it. This is the Airy pattern.

For a circular aperture of diameter DD in air, the first dark ring lies at a small angle θR\theta_R from the centre. For two equally bright incoherent points, the Rayleigh criterion places the peak of one pattern at the first minimum of the other. This produces a reference separation.

θR≃1.22λD.\theta_R\simeq1.22\frac{\lambda}{D}.

An objective's numerical aperture expresses the corresponding separation in its object plane.

dR≃0.61λNA,NA=nsin⁡α.d_R\simeq\frac{0.61\lambda}{\mathrm{NA}},\qquad \mathrm{NA}=n\sin\alpha .

Here dRd_R is the separation on the object side of an ideal microscope, λ\lambda is the vacuum wavelength, nn is the refractive index on the object side and α\alpha is the half-angle of the accepted cone. With λ=550 nm\lambda=550\,\mathrm{nm} and NA=0.45\mathrm{NA}=0.45, the Rayleigh separation is about 0.746 μm0.746\,\mu\mathrm m. A shorter wavelength or larger numerical aperture gives a smaller spot in this scalar idealization. Raising magnification alone makes the spot appear larger on the sensor.

4.2 A periodic object needs more than its average

4.2.1 Follow the grating orders into the pupil

A grating with full period pp produces diffracted orders spaced by λ/p\lambda/p in the sine of the angle in air. With illumination at angle θi\theta_i from the axis and tilt aligned with the grating normal in the transverse plane, order mm enters the clear pupil if

∣sin⁡θi+mλp∣≤NA.\left|\sin\theta_i+m\frac{\lambda}{p}\right|\leq\mathrm{NA}.

Choose the sign of θi\theta_i along the direction in which the grating repeats. With illumination on axis, both first orders lie outside the pupil whenever p<λ/NAp<\lambda/\mathrm{NA}. The zero-order field is uniform, so passing only that order gives a uniform image. When a first order also passes, its field interferes with the zero order. The difference between their spatial frequencies makes the original stripe period visible.

Tilting the illumination shifts all orders together. For a tilt aligned with the grating's repeat direction, the first order on one side moves inward. The support limit is p=λ/(NA+∣sin⁡θi∣)p=\lambda/(\mathrm{NA}+|\sin\theta_i|). The ideal aligned edge-illumination limit occurs at ∣sin⁡θi∣=NA|\sin\theta_i|=\mathrm{NA} and gives the Abbe full period λ/(2NA)\lambda/(2\mathrm{NA}). This is a criterion about periodic structure under specified illumination. The Rayleigh criterion applies to two incoherent points.

4.2.2 Recover the period in the grating Lab

Open Abbe Resolution Lab. Compare Axial: invisible stripes and Tilt: recover the period. Both use λ=550 nm\lambda=550\,\mathrm{nm}, p=800 nmp=800\,\mathrm{nm} and NA=0.45\mathrm{NA}=0.45. Under axial illumination only order zero passes. Under the tilted illumination, sin⁡θi=0.405\sin\theta_i=0.405, the minus first order moves to a sine coordinate of −0.2825-0.2825 and passes too.

  • Axial illumination
  • Oblique illumination
The same grating viewed with axial and oblique illuminationWith axial illumination, the receiver is flat at a quarter of the reference intensity. With oblique illumination, its signal varies periodically between one sixteenth and nine sixteenths.

Figure 4.1 Two simulated receiving-intensity line cuts over one full grating period. The grating pitch, wavelength and pupil are the same in both trials. Axial illumination passes only the uniform contribution. With oblique illumination a first order enters and the receiving intensity varies at the grating period.

Table 4.1 Admitted orders and intensity contrast from the simulated receiver. Contrast is the intensity difference between maximum and minimum divided by their sum.
PresetOrders passedContrastPeriod in the intensity
Axial0000Uniform
Tilt−1,0-1,00.8000.800800 nm800\,\mathrm{nm}
Block zero−1,+1-1,+1nearly 11700 nm700\,\mathrm{nm}

The third row comes from Block zero: false half-pitch, which uses a different grating with a full period of 1400 nm1400\,\mathrm{nm}. The two passed first orders differ by twice the original spatial frequency. Their interference creates an intensity period of 700 nm700\,\mathrm{nm}. This extra stripe frequency comes from the selected orders.

4.3 Track what happens to contrast

For incoherent imaging, each object point contributes an intensity pattern. The point-spread function, or PSF, is the intensity response to a point source. When it has the same shape everywhere, the image intensity is a sum of shifted copies of that pattern weighted by the object intensity. This operation is a convolution.

The optical transfer function, or OTF, is the Fourier transform of the normalized PSF. It tells how the system changes the contrast and phase of each sinusoidal component. Its magnitude is the modulation transfer function, or MTF.

OTF(ν)=F{PSF}(ν),MTF(ν)=∣OTF(ν)∣.\mathrm{OTF}(\boldsymbol\nu)=\mathcal F\{\mathrm{PSF}\}(\boldsymbol\nu),\qquad \mathrm{MTF}(\boldsymbol\nu)=|\mathrm{OTF}(\boldsymbol\nu)|.

The spatial frequency ν\boldsymbol\nu counts cycles per unit distance in a specified direction. If the OTF is real and negative at a frequency, a sinusoid there comes out with bright and dark positions interchanged. The MTF gives the size of the remaining contrast. Under coherent light, field amplitudes combine before the square gives intensity. The grating exercise uses that coherent case.

4.4 Separate optical blur from sampling

Open PSF–OTF–MTF Imaging Lab and choose Defocus: bright becomes dark. This preset uses an incoherent sinusoidal target. At the target frequency of about 0.0703 μm−10.0703\,\mu\mathrm m^{-1}, the signed transfer is about −0.0823-0.0823. The image keeps a small modulation with its bright and dark positions reversed. Look for the negative transfer and compare the bright bands of the target and the geometric image reference with the defocused image.

Now choose Pixels: false stripe period. The optical image contains the input frequency 0.171875 μm−10.171875\,\mu\mathrm m^{-1}. The simulated pixels are spaced 4.00 μm4.00\,\mu\mathrm m apart and sample at 0.250 μm−10.250\,\mu\mathrm m^{-1}. The input frequency exceeds the Nyquist frequency 0.125 μm−10.125\,\mu\mathrm m^{-1} and appears in the pixel record at 0.078125 μm−10.078125\,\mu\mathrm m^{-1}.

The receiver model averages over each pixel block before sampling. Averaging reduces some of the contrast. It can still leave enough modulation to masquerade as a coarser pattern. In this preset, the false period comes from sampling the optical image. In the grating preset where zero order is blocked, the false period already exists in the optical intensity.

4.5 Exercises

  1. An ideal circular aperture gives a Rayleigh angular separation of 2.0 mrad2.0\,\mathrm{mrad}. If the diameter doubles at the same wavelength, what is the new angular separation?
  2. A microscope works at 600 nm600\,\mathrm{nm} and NA=0.60\mathrm{NA}=0.60. Estimate the Rayleigh separation for two equally bright incoherent point sources.
  3. For the tilted Abbe preset, verify that order −1-1 passes but order +1+1 does not using the pupil limit.
  4. A coherent sinusoidal grating is illuminated on axis and only its zero order reaches the image. What becomes of its contrast?
  5. A grating has full period 1.20 μm1.20\,\mu\mathrm m. Only its two first orders pass. What period appears in the optical intensity? Where did it come from?
  6. For an incoherent sinusoidal image a real OTF is −0.20-0.20 at the target frequency. What does the MTF say, and what does the sign add?
  7. A sensor samples every 5.00 μm5.00\,\mu\mathrm m. Find its Nyquist frequency. A residual sinusoid at 0.140 μm−10.140\,\mu\mathrm m^{-1} reaches the sensor. What lower frequency can the samples represent?
  8. Would doubling magnification while keeping wavelength and object-side NA fixed halve the Rayleigh separation in the object plane? Explain.
Exercise 1

It halves to 1.0 mrad1.0\,\mathrm{mrad} because the first dark-ring angle is proportional to 1/D1/D.

Exercise 2

The estimate is dR=0.61λ/NA=0.610 μmd_R=0.61\lambda/\mathrm{NA}=0.610\,\mu\mathrm m. This criterion compares two overlapping point patterns.

Exercise 3

The sine coordinates are about −0.2825-0.2825 and 1.09251.0925. Only the first has magnitude at most 0.450.45. The second is even beyond the propagating sine range.

Exercise 4

The intensity is uniform and the contrast is zero. A single transmitted plane-wave order has no intensity modulation across the image.

Exercise 5

The intensity period is 0.600 μm0.600\,\mu\mathrm m. The two orders' spatial frequencies differ by twice the grating frequency, so the interference term has half the pitch.

Exercise 6

The MTF is 0.200.20, so the output modulation has one fifth of the input magnitude. The negative sign tells you that the bright and dark positions swap.

Exercise 7

The sampling frequency is 0.200 μm−10.200\,\mu\mathrm m^{-1} and Nyquist is 0.100 μm−10.100\,\mu\mathrm m^{-1}. The residual sinusoid folds to 0.060 μm−10.060\,\mu\mathrm m^{-1}, the difference between its frequency and the sampling frequency.

Exercise 8

The object-side Rayleigh separation stays the same because λ\lambda and NA\mathrm{NA} stay fixed. The image covers more distance on the sensor, but the optical spot scales up with it.

Test it in the Lab

Change one setting at a time, then compare what you see with the tables and answers in this chapter.

Abbe Resolution Lab →Select diffraction orders on an Abbe–Porter bench. Recover a hidden grating with oblique illumination, open the pupil and see how false half-pitch detail appears.PSF–OTF–MTF Imaging Lab →Follow light from the pupil to the image and see contrast reversal and false periods caused by sampling. The PSF, the signed OTF, the MTF and the sensor pixels all come from the same calculation.

Sources and reading scope

  1. OpenStax, University Physics Volume 3, §4.5 Circular Apertures and Resolution

    The section derives the angular width of the central diffraction spot and relates it to the Rayleigh criterion.

  2. Evident Scientific, Spatial Frequency and Image Resolution

    The microscope examples show how the diffraction orders admitted by an objective determine which grating detail reaches the image.

  3. MIT 2.710 Optics, Week 11 Coherent and Incoherent Imaging

    The lecture derives coherent and incoherent transfer functions from the pupil and illustrates the corresponding spatial frequency cutoffs.

  4. Nikon MicroscopyU, Numerical Aperture

    Numerical aperture depends on the medium’s refractive index and the half angle of the admitted cone.

Keep reading

What this page links to directly

See this series on the content map →

Interactive Physics Textbook · Reading path

Light, Imaging and Measurement

  1. ArticleWhere does light go at an interface?
  2. ArticleHow does a lens form an image?
  3. ArticleHow do two paths produce bright and dark fringes?
  4. You are hereWhat sets the finest detail an optical system can resolve?
  5. ArticleHow does a detector measure polarization?
  6. ArticleHow do gain and feedback make a laser oscillate?
Something broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy