After this chapter you can: Use wavelength and numerical aperture to estimate resolvable detail and interpret a contrast transfer curve.
A finite aperture spreads the light from a point into a spot. Nearby spots can overlap, and closely spaced stripes can lose contrast when the aperture blocks the diffracted light that carries their pattern. A resolution limit depends on what you are trying to distinguish, how the object is illuminated and how the image is sampled.
4.1 A circular aperture gives a point image finite width
The geometric focus of Chapter 2 locates the centre of a point image. Light admitted through the whole pupil also interferes around that centre. A clear, uniformly filled circular pupil creates a bright central disk with weaker rings around it. This is the Airy pattern.
For a circular aperture of diameter D in air, the first dark ring lies at a small angle θR from the centre. For two equally bright incoherent points, the Rayleigh criterion places the peak of one pattern at the first minimum of the other. This produces a reference separation.
θR≃1.22Dλ.
An objective's numerical aperture expresses the corresponding separation in its object plane.
dR≃NA0.61λ,NA=nsinα.
Here dR is the separation on the object side of an ideal microscope, λ is the vacuum wavelength, n is the refractive index on the object side and α is the half-angle of the accepted cone. With λ=550nm and NA=0.45, the Rayleigh separation is about 0.746μm. A shorter wavelength or larger numerical aperture gives a smaller spot in this scalar idealization. Raising magnification alone makes the spot appear larger on the sensor.
4.2 A periodic object needs more than its average
4.2.1 Follow the grating orders into the pupil
A grating with full period p produces diffracted orders spaced by λ/p in the sine of the angle in air. With illumination at angle θi from the axis and tilt aligned with the grating normal in the transverse plane, order m enters the clear pupil if
sinθi+mpλ≤NA.
Choose the sign of θi along the direction in which the grating repeats. With illumination on axis, both first orders lie outside the pupil whenever p<λ/NA. The zero-order field is uniform, so passing only that order gives a uniform image. When a first order also passes, its field interferes with the zero order. The difference between their spatial frequencies makes the original stripe period visible.
Tilting the illumination shifts all orders together. For a tilt aligned with the grating's repeat direction, the first order on one side moves inward. The support limit is p=λ/(NA+∣sinθi∣). The ideal aligned edge-illumination limit occurs at ∣sinθi∣=NA and gives the Abbe full period λ/(2NA). This is a criterion about periodic structure under specified illumination. The Rayleigh criterion applies to two incoherent points.
4.2.2 Recover the period in the grating Lab
Open Abbe Resolution Lab. Compare Axial: invisible stripes and Tilt: recover the period. Both use λ=550nm, p=800nm and NA=0.45. Under axial illumination only order zero passes. Under the tilted illumination, sinθi=0.405, the minus first order moves to a sine coordinate of −0.2825 and passes too.
Figure 4.1 Two simulated receiving-intensity line cuts over one full grating period. The grating pitch, wavelength and pupil are the same in both trials. Axial illumination passes only the uniform contribution. With oblique illumination a first order enters and the receiving intensity varies at the grating period.
Table 4.1 Admitted orders and intensity contrast from the simulated receiver. Contrast is the intensity difference between maximum and minimum divided by their sum.
Preset
Orders passed
Contrast
Period in the intensity
Axial
0
0
Uniform
Tilt
−1,0
0.800
800nm
Block zero
−1,+1
nearly 1
700nm
The third row comes from Block zero: false half-pitch, which uses a different grating with a full period of 1400nm. The two passed first orders differ by twice the original spatial frequency. Their interference creates an intensity period of 700nm. This extra stripe frequency comes from the selected orders.
4.3 Track what happens to contrast
For incoherent imaging, each object point contributes an intensity pattern. The point-spread function, or PSF, is the intensity response to a point source. When it has the same shape everywhere, the image intensity is a sum of shifted copies of that pattern weighted by the object intensity. This operation is a convolution.
The optical transfer function, or OTF, is the Fourier transform of the normalized PSF. It tells how the system changes the contrast and phase of each sinusoidal component. Its magnitude is the modulation transfer function, or MTF.
OTF(ν)=F{PSF}(ν),MTF(ν)=∣OTF(ν)∣.
The spatial frequency ν counts cycles per unit distance in a specified direction. If the OTF is real and negative at a frequency, a sinusoid there comes out with bright and dark positions interchanged. The MTF gives the size of the remaining contrast. Under coherent light, field amplitudes combine before the square gives intensity. The grating exercise uses that coherent case.
4.4 Separate optical blur from sampling
Open PSF–OTF–MTF Imaging Lab and choose Defocus: bright becomes dark. This preset uses an incoherent sinusoidal target. At the target frequency of about 0.0703μm−1, the signed transfer is about −0.0823. The image keeps a small modulation with its bright and dark positions reversed. Look for the negative transfer and compare the bright bands of the target and the geometric image reference with the defocused image.
Now choose Pixels: false stripe period. The optical image contains the input frequency 0.171875μm−1. The simulated pixels are spaced 4.00μm apart and sample at 0.250μm−1. The input frequency exceeds the Nyquist frequency 0.125μm−1 and appears in the pixel record at 0.078125μm−1.
The receiver model averages over each pixel block before sampling. Averaging reduces some of the contrast. It can still leave enough modulation to masquerade as a coarser pattern. In this preset, the false period comes from sampling the optical image. In the grating preset where zero order is blocked, the false period already exists in the optical intensity.
4.5 Exercises
An ideal circular aperture gives a Rayleigh angular separation of 2.0mrad. If the diameter doubles at the same wavelength, what is the new angular separation?
A microscope works at 600nm and NA=0.60. Estimate the Rayleigh separation for two equally bright incoherent point sources.
For the tilted Abbe preset, verify that order −1 passes but order +1 does not using the pupil limit.
A coherent sinusoidal grating is illuminated on axis and only its zero order reaches the image. What becomes of its contrast?
A grating has full period 1.20μm. Only its two first orders pass. What period appears in the optical intensity? Where did it come from?
For an incoherent sinusoidal image a real OTF is −0.20 at the target frequency. What does the MTF say, and what does the sign add?
A sensor samples every 5.00μm. Find its Nyquist frequency. A residual sinusoid at 0.140μm−1 reaches the sensor. What lower frequency can the samples represent?
Would doubling magnification while keeping wavelength and object-side NA fixed halve the Rayleigh separation in the object plane? Explain.
Exercise 1Show the answer
It halves to 1.0mrad because the first dark-ring angle is proportional to 1/D.
Exercise 2Show the answer
The estimate is dR=0.61λ/NA=0.610μm. This criterion compares two overlapping point patterns.
Exercise 3Show the answer
The sine coordinates are about −0.2825 and 1.0925. Only the first has magnitude at most 0.45. The second is even beyond the propagating sine range.
Exercise 4Show the answer
The intensity is uniform and the contrast is zero. A single transmitted plane-wave order has no intensity modulation across the image.
Exercise 5Show the answer
The intensity period is 0.600μm. The two orders' spatial frequencies differ by twice the grating frequency, so the interference term has half the pitch.
Exercise 6Show the answer
The MTF is 0.20, so the output modulation has one fifth of the input magnitude. The negative sign tells you that the bright and dark positions swap.
Exercise 7Show the answer
The sampling frequency is 0.200μm−1 and Nyquist is 0.100μm−1. The residual sinusoid folds to 0.060μm−1, the difference between its frequency and the sampling frequency.
Exercise 8Show the answer
The object-side Rayleigh separation stays the same because λ and NA stay fixed. The image covers more distance on the sensor, but the optical spot scales up with it.
Test it in the Lab
Change one setting at a time, then compare what you see with the tables and answers in this chapter.