Skip to main content
Sandbox Physics
Volume 4 · Light, Imaging and Measurement

How does a detector measure polarization?

Measure transmitted power under six analyzer settings to recover polarization, including the circular component a linear scan misses.

Before you start: Volume 3 Chapter 7 on electromagnetic waves, Volume 2 Chapter 5 on phase, and Chapter 3 of this volume on interference.

After this chapter you can: Use analyzer readings to find the Stokes parameters and explain which component needs a circular analyzer.

A detector behind a polarizer measures the power that passes. Turning a linear polarizer shows which direction the electric field favors. Opposite rotations of the field can give the same linear scan. A quarter-wave plate converts that difference into a power difference the detector can read.

Volume 3, Chapter 7, introduced the electric field of a transverse light wave. In this chapter, relative phase determines the shape traced by the field. Different analyzer settings turn that shape and its sense of rotation into measurable power differences.

5.1 Two transverse amplitudes and one relative phase determine the ellipse

Look at one position along a monochromatic beam. Choose transverse axes xx and yy so that they and the propagation direction form a right-handed set. Let the amplitudes along the two axes be AxA_x and AyA_y. Take the first component to have initial phase zero and let the second have relative phase δ\delta. With the time convention e−iωt\mathrm e^{-i\omega t}, the complex amplitudes form a Jones vector.

J=(AxAyeiδ).\mathbf J= \begin{pmatrix} A_x\\ A_y\mathrm e^{i\delta}\end{pmatrix}.

Take the real part after applying the common time factor to recover the electric field.

E(t)=Re⁡(Je−iωt).\mathbf E(t)=\operatorname{Re}(\mathbf J\mathrm e^{-i\omega t}) .

With zero relative phase, both components reach their largest values together. The field tip moves along a line. With equal amplitudes and δ=±π/2\delta=\pm\pi/2, one component is at its largest when the other vanishes. The field tip moves around a circle. Switching the sign of the phase reverses its sense of rotation. Other combinations generally trace ellipses. Adding the same phase to both components changes where you start watching the cycle. NIST SCATMECH, JonesVector.

5.2 A linear analyzer reads the orientation but leaves the rotation unresolved

A linear analyzer with transmission axis at angle α\alpha from the horizontal takes the projection along that axis. For a pure state, the transmitted power in normalized units is ∣Jxcos⁡α+Jysin⁡α∣2|J_x\cos\alpha+J_y\sin\alpha|^2. The two component magnitudes and the real part of Jx∗JyJ_x^*J_y set that power. The star means complex conjugate. Call the total power S0S_0, the horizontal minus vertical power S1S_1, and the power at 45∘45^\circ minus that at 135∘135^\circ S2S_2. Expanding the squared projection gives

I(α)=12(S0+S1cos⁡2α+S2sin⁡2α).I(\alpha)=\tfrac12\bigl(S_0+S_1\cos 2\alpha+S_2\sin 2\alpha\bigr).

For linear input tilted by an angle ψ\psi, this reduces to I(α)=S0cos⁡2(α−ψ)I(\alpha)=S_0\cos^2(\alpha-\psi), Malus's law. Opposite phases of the same magnitude in the Jones vector give the same real part of the product and thus the same linear scan. Circular input gives a flat scan at half the incident power. Unpolarized light also gives a flat scan at that level, because it has equal average power along any two perpendicular axes. OpenStax, University Physics Volume 3, Section 1.7.

Figure 5.1 compares the scans. Two inputs with a polarized fraction of 0.800.80 and ellipse axis at 30∘30^\circ have ellipticity angles of +20∘+20^\circ and −20∘-20^\circ. Their linear scans coincide. The ellipticity angle sets the signed short-to-long axis ratio through its tangent.

  • Linear input
  • Opposite ellipticities (same trace)
  • Circular input
Linear analyzer power for three input polarization statesLinear input reaches zero and one. The opposite ellipticities have identical traces between about 0.19 and 0.81. Circular input gives constant power of one half.

Figure 5.1 Calculated transmitted fraction as an ideal linear analyzer turns. Reversing the sense of rotation of the elliptical part leaves the transmitted fraction at every angle unchanged.

5.3 A quarter-wave plate gives a separate circular measurement

A quarter-wave plate changes the relative phase between its fast and slow axes by a quarter cycle. With the right orientation, it turns one circular state into horizontal linear polarization and the opposite circular state into vertical polarization. A horizontal analyzer then passes one and blocks the other. Rotate the quarter-wave plate's axes by a right angle to exchange the states the analyzer passes and blocks.

Use H and V for the horizontal and vertical analyzer settings. Use D and A for the diagonal settings at 45∘45^\circ and 135∘135^\circ. Use L and R for the two circular settings. We follow the NIST convention, with the Jones vector proportional to (1,i)(1,i) for L and (1,−i)(1,-i) for R. The circular Stokes component S3S_3 is the L power minus the R power. Together the four Stokes components also describe mixed light, including a superposition of average powers from a polarized beam and unpolarized light. NIST SCATMECH, StokesVector.

Call the six separate exposure counts NH,NV,ND,NA,NL,NRN_H,N_V,N_D,N_A,N_L,N_R and the known incident count expectation per exposure N0N_0. With ideal analyzer transmission along the selected axis and equal exposures, each pair sum estimates the total power after dividing by the incident expectation. For six measurements the estimates in units of incident power are

S^0=NH+NV+ND+NA+NL+NR3N0,S^1=NH−NVN0,S^2=ND−NAN0,S^3=NL−NRN0.\begin{aligned} \widehat S_0 &= \frac{N_H+N_V+N_D+N_A+N_L+N_R}{3N_0},\\ \widehat S_1 &= \frac{N_H-N_V}{N_0},\\ \widehat S_2 &= \frac{N_D-N_A}{N_0},\\ \widehat S_3 &= \frac{N_L-N_R}{N_0}. \end{aligned}

For nonzero total power, the degree of polarization is p=S12+S22+S32/S0p=\sqrt{S_1^2+S_2^2+S_3^2}/S_0. The range for a physical state is zero to one. A finite-count estimate can stray outside that range. The separate count records still tell you how the estimate was obtained.

5.4 Reconstruct polarization from the six detector records

Open Polarization State Explorer and choose Stokes polarimetry. The polarized part has ellipse axis at 30∘30^\circ and ellipticity angle 20∘20^\circ. It accounts for 0.800.80 of the source power. Leave the expected incident electrons per equal exposure at N0=10000N_0=10000. Select Expectation records, then Poisson counts. The first setting reports expected counts. The second supplies one simulated integer sample with the same underlying source.

Table 5.1 The six analyzer exposures for the preset. The expected counts are rounded here. The noisy column shows one reproducible simulated sample.
SettingExpected electronsSimulated count
H6532.096473
V3467.913427
D7653.667586
A2346.342369
L7571.157440
R2428.852420

In the noisy record the L and R difference is 50205020 counts. Dividing by the incident expectation gives S^3=0.5020\widehat S_3=0.5020. Using all six counts gives S^0=0.9905\widehat S_0=0.9905, S^1=0.3046\widehat S_1=0.3046 and S^2=0.5217\widehat S_2=0.5217. The estimated polarization degree is about 0.7930.793. The known simulated input has degree 0.8000.800. The two values differ because each exposure is a finite count sample.

Now select Linear records only and see which estimate becomes unavailable. The H, V, D and A records still give the linear components. Without L and R, the data leave the circular component undetermined. Restore Add circular records, switch back to Expectation records and change the ellipticity angle from 20∘20^\circ to −20∘-20^\circ. The linear records stay the same and the circular pair swaps. This model assumes equal exposures, known incident flux and ideal optics.

5.5 Exercises

  1. Two electric-field components of equal amplitude start with the same phase. Which shape does their vector trace? What changes if the second component is delayed by a quarter cycle?
  2. An ideal analyzer's axis is at 30∘30^\circ to a linearly polarized input. What fraction of power passes? Why does the square enter?
  3. A rotating linear analyzer gives one half of the incident power at every angle. Give two different input states that can produce this scan.
  4. In the phase convention of this chapter, two states have Jones vectors proportional to (1,i)(1,i) and (1,−i)(1,-i). How can a detector tell them apart using a quarter-wave plate and a linear analyzer?
  5. At fixed incident power, expected H, V, D and A measurements give 700700, 300300, 600600 and 400400 counts with N0=1000N_0=1000. Find the normalized linear Stokes components. Can you infer the circular component?
  6. Add L and R measurements of 800800 and 200200 to Exercise 5. Compute the circular component and degree of polarization.
  7. In Table 5.1, why do the three noisy pair sums differ from each other? Which recorded quantities set the estimated total power?
  8. Suppose an estimate gives a polarization degree of 1.021.02 after six low-count exposures. What does it say about the recorded sample and what would help improve the estimate?

5.6 Answers and explanations

Exercise 1

The two components grow and shrink together, so the field traces a diagonal line. With a quarter-cycle delay, the components alternate between their peaks and their zeros, tracing a circle.

Exercise 2

The transmitted fraction is cos⁡230∘=0.75\cos^2 30^\circ=0.75. Projection multiplies the field amplitude by the cosine. The detector measures power, which is proportional to amplitude squared.

Exercise 3

Circular polarization and unpolarized light both give the same flat linear scan. In a circular state the field rotates uniformly. For unpolarized light the average power is the same along every linear axis.

Exercise 4

Set the wave plate so that the first state becomes horizontal. The opposite circular state then becomes vertical. A horizontal analyzer passes the first and blocks the second. The L and R settings exchange their roles when the wave plate axes are swapped.

Exercise 5

The differences give S^1=0.400\widehat S_1=0.400 and S^2=0.200\widehat S_2=0.200. The two pair sums each give S^0=1.00\widehat S_0=1.00. A linear analyzer has no term proportional to the circular component, so the four counts leave it undetermined.

Exercise 6

The L minus R count is six hundred, giving S^3=0.600\widehat S_3=0.600. All pair sums equal the incident expectation, so the total stays one. The degree is 0.4002+0.2002+0.6002≈0.748\sqrt{0.400^2+0.200^2+0.600^2}\approx0.748.

Exercise 7

Each detector exposure has a separate random count. The estimated total is the average of the three pair sums after dividing each by the expected incident count. You can use Table 5.1 to reproduce S^0=0.9905\widehat S_0=0.9905.

Exercise 8

The estimate is outside the physical range, which can happen when count fluctuations move the differences or the total. Collect more counts by taking more equal, calibrated exposures or using longer exposures if the source stays stable.

Test it in the Lab

Change one setting at a time, then compare what you see with the tables and answers in this chapter.

Polarization State Explorer →Rotate polarizers on a bench to see Malus’s law and the third-polarizer effect, then measure Stokes parameters from counts and see when the handedness becomes ambiguous.

Sources and reading scope

  1. OpenStax, University Physics Volume 3, §1.7 Polarization

    The section explains polarization through the direction of the electric field and relates the angle of a linear analyzer to the transmitted intensity.

  2. NIST SCATMECH, JonesVector

    The documentation defines the complex field components of the Jones vector and states its time and basis conventions.

  3. NIST SCATMECH, StokesVector

    The documentation defines the four Stokes components through polarization-resolved intensities and states the circular sign convention.

Keep reading

What this page links to directly

See this series on the content map →

Interactive Physics Textbook · Reading path

Light, Imaging and Measurement

  1. ArticleWhere does light go at an interface?
  2. ArticleHow does a lens form an image?
  3. ArticleHow do two paths produce bright and dark fringes?
  4. ArticleWhat sets the finest detail an optical system can resolve?
  5. You are hereHow does a detector measure polarization?
  6. ArticleHow do gain and feedback make a laser oscillate?
Something broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy