After this chapter you can: Relate a flavor survival probability to a rate or spectrum and identify the detector corrections needed for comparison.
Reactor antineutrinos leave a smaller signal at a far detector, with a deficit that varies across energies. Near detectors help predict what the far detector would see without oscillations. The rate deficit and its change with energy give separate information about the oscillation.
Chapter 1 followed a detector signal through calibration. Here the recorded signal is a pair of pulses, and the evidence comes from comparing spectra built from many such pairs.
5.1 Two pulses identify a candidate event
An electron antineutrino can interact with a proton by inverse beta decay.
νˉe+p⟶e++n.
The positron slows down and annihilates, producing a prompt signal. The neutron is captured later and produces a second signal. The timing, energies and locations of the two signals help separate candidate events from backgrounds. In the Daya Bay sample used here, the delayed signal comes from neutron capture on gadolinium.
The detector bins the calibrated prompt energy Ep. The incident antineutrino energy E is larger. At leading order the difference comes from the neutron–proton mass difference and the positron rest energy, with neutron recoil neglected.
E≃Ep+0.78MeV.
Energy calibration sets the scale used to assign events to reconstructed bins. Finite energy resolution spreads events with the same incident energy across several bins. Both effects enter the predicted prompt spectrum. Daya Bay Collaboration, 2023 measurement.
5.2 Oscillation phase sets the energy of the dip
An electron antineutrino starts as a superposition of mass states. These components acquire different phases as they propagate. The probability of detecting the electron flavor depends on their interference at the detector. Over a few kilometers, the leading oscillation at reactor energies has amplitude A≃sin2(2θ13). Keeping one effective mass-squared difference Δm2 and leaving out the slower solar oscillation and matter effects gives
Pee(E,L)≃1−Asin2(1.267eV2Δm2E/MeVL/m).
Here L is the baseline from source to detector. Mass-squared differences use natural units with c=1. At fixed baseline the first minimum encountered as energy decreases occurs when the magnitude of the phase reaches π/2. In the teaching Lab, L=1.65km and Δm2=2.45×10−3eV2 give E≃3.26MeV. Before detector smearing, that corresponds to Ep≃2.48MeV. The depth of the ideal dip is set by the amplitude, and its energy at fixed baseline is set by the mass-squared difference. Daya Bay Collaboration, Eqs. 1 and 2.
5.3 The near spectrum constrains the far prediction
Even with no oscillation, flux from one point source falls as 1/L2. A far detector can also have a different target size and live time. Comparing the raw counts mixes these effects with oscillation. For one point source, a simple prediction for detector d and prompt-energy bin i is
Here Cd is the number of target protons, Td the live time and Bdi the expected background count. The common source spectrum Φ includes the isotropic geometric constant. The cross section σ describes the interaction. The detector response Rdi gives the probability of an interaction at that energy being accepted and assigned to the bin.
The near spectrum constrains the common source contribution. The prediction still needs the geometry, detector response and background. A real array with several cores adds their contributions at their individual baselines. For a no-oscillation comparison use unit survival probability. For an oscillation fit, compare both sites' observed counts with the model means across the available bins.
Daya Bay's 2012 rate analysis found a far-site observed-to-predicted ratio of 0.940±0.011(stat)±0.004(syst) relative to the no-oscillation expectation. The 2023 analysis fit the rate and spectral shape using 5.55 million candidates from 3158 days of operation. Its three-flavor fit gave the values below for normal mass ordering.
In the collaboration's Figure 2, the measured prompt spectra and their ratios to no-oscillation predictions are shown separately for the three halls. The public data release contains detector histograms, live times, efficiencies and background inputs for reproducing the fit. Daya Bay 2012 discovery paper, Daya Bay 2023 measurement, Figure 2, Daya Bay public data release.
5.4 Refit the same simulated counts under a different calibration
Open Reactor Near–Far Spectra and choose Reset. The frozen near and far records contain 36,511 and 13,496 counts including underflow and overflow. The default analysis gives a fitted disappearance amplitude of 0.0713. The Lab uses one reactor, simplified detector response, known background and a fixed mass-squared difference. It fits Poisson counts while allowing a common flux multiplier and a constrained far-to-near normalization.
Simulated count
Fit with disappearance
Refit without disappearance
Far-detector counts per bin0150300450600Difference from the no-disappearance fit−50−2502512345678
Prompt energy (megaelectronvolts)
Figure 5.1 Recorded far-detector counts from the teaching simulation, compared with the fitted means and the means from a separate fit with zero disappearance amplitude. Both fits use the near and far records.
The far bin from 3.00 to 3.25MeV has 461 counts. The fitted and zero-amplitude predictions for that bin are about 446.5 and 463.7. This bin is closer to the zero-amplitude prediction. Across the full record the oscillation fit achieves the smaller Poisson deviance, 61.32 versus 71.90. The deviance measures disagreement across the bins and includes the normalization constraint. A single noisy bin can favor a different model from the combined spectrum.
Now change Assumed far energy-scale offset to +2% without acquiring again. The fitted amplitude changes to 0.0079 and the deviance increases to 78.75. The same events remain in the same recorded bins. The analysis changes which events the model expects in those bins. Use Export counts & scan (CSV) before and after the change to check that the count columns agree. The change illustrates why a fit needs independent calibration information.
5.5 Exercises
What produces the prompt and delayed signals in a reactor inverse beta decay candidate?
A candidate has reconstructed prompt energy 2.50MeV. Estimate its antineutrino energy with the leading relation.
Two equal detectors observe a point source from 0.50km and 1.50km. With identical live times and no background or oscillation, what far-to-near ratio do you expect?
In the leading oscillation model, what happens to the first dip's energy if the baseline doubles? What happens to the depth?
Why does the far sample's count being lower than the near sample's count fail to establish disappearance?
In Figure 5.1 why can one bin be closer to the zero-amplitude model even when the full spectral fit favors disappearance?
At fixed model assumptions and the same event rate, how does four times the exposure affect a bin's fractional Poisson standard deviation?
After changing only the assumed far energy scale in the Lab, which quantities in the export should agree? Why can the best-fit amplitude change?
5.6 Answers and explanations
Exercise 1Show the answer
The positron deposits kinetic energy and annihilates, giving the prompt signal. The neutron capture produces the delayed signal. Their coincidence helps identify the interaction.
Exercise 2Show the answer
Add the leading offset to obtain 2.50+0.78=3.28MeV. Recoil and detector resolution limit how accurately an individual candidate can give the incident energy.
Exercise 3Show the answer
The geometric ratio is (0.50/1.50)2=1/9. In this setup the target and live-time factors cancel.
Exercise 4Show the answer
The phase depends on L/E, so the first dip moves to twice the energy. The minimum survival probability is 1−A at either baseline.
Exercise 5Show the answer
Flux spreads out with distance, so a far detector can see fewer events with unit survival probability. A meaningful comparison uses a prediction that accounts for the geometry, exposure, efficiency and backgrounds.
Exercise 6Show the answer
Each bin has counting fluctuations. The joint fit asks how well the model predicts all bins at both detectors while accounting for the allowed normalization shift. One fluctuation can locally improve agreement with the model that fits the whole record less well.
Exercise 7Show the answer
For mean count μ, the Poisson standard deviation is μ, so the fractional spread is 1/μ. Four times the exposure halves that fractional spread.
Exercise 8Show the answer
The energy-bin boundaries and both observed count columns agree. The assumed calibration changes the far response in the forward model and therefore changes which amplitude best fits the same counts.
Test it in the Lab
Change one setting at a time, then compare what you see with the tables and answers in this chapter.