Skip to main content
Sandbox Physics
Volume 7 · Learning the Microscopic World from Experiments

How does the end of a beta spectrum constrain neutrino mass?

Compare the predicted beta-decay endpoint with detector counts. See how resolution and background affect the mass constraint.

Before you start: Volume 5 Chapter 2 on distributions and Volume 6 Chapter 3 on energy. Chapter 4 covers spectra and Chapter 5 covers selected counts.

After this chapter you can: Trace how the endpoint model predicts detector counts and interpret the fit’s conditional mass range.

A massive neutrino changes the shape of the beta-electron spectrum near its highest energies. A threshold spectrometer counts how many electrons pass at each voltage. The inference compares those counts with predictions for different masses, allowing for the instrument response, the background and the endpoint calibration.

6.1 Neutrino mass changes the spectrum near its end

In tritium beta decay, the electron shares the released energy with an electron antineutrino and the recoiling daughter. Let EE be the electron kinetic energy. In a simplified spectrum for one daughter state, let E0E_0 be the massless endpoint, ϵ=E0−E\epsilon=E_0-E, and w=mβc2w=m_\beta c^2 be the effective neutrino rest energy. Near the endpoint, take the slowly varying electron and Coulomb factors as constant. The remaining differential spectrum is proportional to

S(E)∝ϵϵ2−w2(ϵ≥w).S(E)\propto \epsilon\sqrt{\epsilon^2-w^2}\qquad(\epsilon\ge w).

This term vanishes when ϵ<w\epsilon<w. For zero mass it becomes ϵ2\epsilon^2. At a fixed electron energy close to the endpoint, a positive mass reduces the momentum available to the neutrino and lowers the rate. Farther below the endpoint, where ϵ≫w\epsilon\gg w, the fractional change is small.

The full spectrum has contributions from the neutrino mass eigenstates. If the detector cannot resolve their separate endpoints and the analysis uses an effective mass, the squared mass is

mβ2=∑i∣Uei∣2mi2,m_\beta^2=\sum_i |U_{ei}|^2 m_i^2,

where mim_i is a mass eigenvalue and ∣Uei∣2|U_{ei}|^2 is its electron-flavor weight. Oscillation data constrain differences between squared masses. The endpoint shape carries information about the absolute scale.

6.2 A voltage scan records counts above a changing threshold

A retarding voltage sets a threshold energy QjQ_j for electrons at scan setting jj. An ideal sharp filter would pass every accepted electron above QjQ_j. In a magnetic adiabatic collimation and electrostatic filter, the fraction transmitted rises over a finite energy interval. The response depends on how the electron's energy is split between motion along and across the magnetic field. For a reduced model with response T(E−Qj)T(E-Q_j), source scale AA, dwell time tjt_j and constant background rate bb, the mean count is

μj=tj[A∫S(E)T(E−Qj) dE+b].\mu_j=t_j\left[A\int S(E)T(E-Q_j)\,\mathrm dE+b\right].

The simulated counts follow independent Poisson distributions with means μj\mu_j. At each setting the detector totals everything that passes during that exposure. The scan is an integral spectrum assembled from separate exposures. A threshold above the endpoint can help constrain the background. A threshold farther below the endpoint gives more counts and helps constrain the source scale.

6.3 A mass estimate depends on the response and calibration

A small shift in E0E_0 or a change in filter width also redistributes counts near the endpoint. The Lab keeps the analysis width fixed at the selected value. At each candidate mβ2≥0m_\beta^2\ge0, it refits the source strength, background and endpoint offset. Call these fit parameters η\boldsymbol\eta. The penalty for disagreeing with the external endpoint calibration enters the deviance DD. The curve shows

ΔD(mβ2)=min⁡ηD(mβ2,η)−Dmin⁡.\Delta D(m_\beta^2)=\min_{\boldsymbol\eta}D(m_\beta^2,\boldsymbol\eta)-D_{\min}.

Here Dmin⁡D_{\min} is the best deviance for that width across the physical mass scan. The Lab reports the range within a deviance rise of one. It can reach the nonnegative boundary, and its coverage is uncalibrated. Comparing curves centered on their own minima also requires looking at the absolute minimum and the count residuals. A steep curve can come from fitting the wrong response.

  • Assumed width 1 eV
  • Assumed width 3 eV
  • One deviance unit
Two likelihood profiles from the same simulated endpoint countsA response width of one electronvolt gives a best squared mass near 1.84. A response width of three electronvolts pushes the minimum to zero and gives a much worse absolute deviance. Each plotted curve is measured from its own minimum.

Figure 6.1 Profiles of the penalized deviance from the same simulated voltage scan. The fits assume filter widths of 1 eV1\,\mathrm{eV} and 3 eV3\,\mathrm{eV}. Each curve is measured from its own minimum. The wider assumption gives a lower fitted mass squared and a worse absolute fit to the counts and calibration.

6.4 Refit the same counts and compare the evidence

Open Beta Endpoint Mass Observatory and choose Reset. The default scan retains 97 99997\,999 simulated counts. Read Fitted mass squared and Minimum penalized deviance. Change Assumed filter width from 1 eV1\,\mathrm{eV} to 3 eV3\,\mathrm{eV} and leave the acquisition untouched. The same scan gives fitted values of about 1.840 eV2/c41.840\,\mathrm{eV}^2/c^4 and zero, while the minimum deviance rises from about 21.7121.71 to 61.5361.53. Use the endpoint offsets and residual plot to see how the fit tries to absorb a response error.

This task holds the slowly varying electron factors fixed and uses a single effective mass and an idealized filter. In its published analysis of 259 days from the first five campaigns, KATRIN reported an upper limit of mβ<0.45 eV/c2m_\beta<0.45\,\mathrm{eV}/c^2 at 90%90\% confidence. That analysis used actual tritium beta-decay counts and accounted for the daughter molecule's final states, electron energy losses in the source and the instrument response. The Lab values above come from its seeded teaching record.

6.5 Exercises

  1. If w=1.2 eVw=1.2\,\mathrm{eV} and ϵ=1.0 eV\epsilon=1.0\,\mathrm{eV}, can an electron at that energy occur in the simplified signal?
  2. At w=1.2 eVw=1.2\,\mathrm{eV} and ϵ=1.5 eV\epsilon=1.5\,\mathrm{eV}, what is the differential signal as a fraction of the massless prediction?
  3. For an ideal sharp threshold with w=0w=0, how does the integrated signal scale with the threshold deficit u=E0−Qu=E_0-Q?
  4. A setting records 480480 events over 3200 s3200\,\mathrm{s}. Find the count rate and its approximate Poisson standard error.
  5. When signal is negligible at a threshold, which fit parameter does the rate chiefly constrain?
  6. Why can an erroneous filter width shift the preferred mass even though the acquisition is unchanged?
  7. A relative deviance curve hits the physical boundary at zero. Can its rise-of-one range by itself supply a calibrated upper limit?
  8. Which measurement constrains the absolute scale, a change of flavor with distance or the tritium endpoint shape? What does the other measure?
Exercise 1

No signal is allowed because ϵ<w\epsilon<w. The neutrino would have less energy available than its rest energy. Background counts can still occur.

Exercise 2

The ratio is 1−(w/ϵ)2=1−0.82=0.60\sqrt{1-(w/\epsilon)^2}=\sqrt{1-0.8^2}=0.60.

Exercise 3

For u>0u>0, the rate is proportional to ∫0uϵ2 dϵ=u3/3\int_0^u \epsilon^2\,\mathrm d\epsilon=u^3/3.

Exercise 4

The rate is 480/3200=0.150 s−1480/3200=0.150\,\mathrm{s}^{-1}. The estimated standard error is 480/3200≃0.00685 s−1\sqrt{480}/3200\simeq0.00685\,\mathrm{s}^{-1}.

Exercise 5

It chiefly constrains the background bb. The rate approaches that constant when there is no transmitted beta signal.

Exercise 6

The width changes which electrons cross each threshold. The fit can partly imitate that change by moving the endpoint or the mass and adjusting the background and source scale.

Exercise 7

Coverage requires a separate statistical construction that accounts for the boundary and the measurement. The Lab range describes a change in the deviance for the assumed fit.

Exercise 8

The beta endpoint constrains an effective absolute mass. Flavor oscillations constrain mass-squared differences and mixing through the distance and energy dependence.

Test it in the Lab

Change one setting at a time, then compare what you see with the tables and answers in this chapter.

Beta Endpoint Mass Observatory →Step an electrostatic threshold across the end of the beta spectrum, record the counts and fit a neutrino mass. See how measuring time, filter width and endpoint calibration change the result.

Sources and reading scope

  1. KATRIN Collaboration, Direct Neutrino-mass Measurement Based on 259 Days of KATRIN Data

    The collaboration reports its fitted mass-squared and a confidence bound on the effective electron-antineutrino mass.

  2. M. Kleesiek et al., Beta-decay Spectrum, Response Function and Statistical Model for Neutrino Mass Measurements with the KATRIN Experiment

    The apparatus description and response equation show how a differential beta spectrum becomes an integrated count rate at a retarding setting.

Keep reading

What this page links to directly

You are hereHow does the end of a beta spectrum constrain neutrino mass?

Articles

See this series on the content map →

Interactive Physics Textbook · Reading path

Learning the Microscopic World from Experiments

  1. ArticleWhat does an instrument record directly?
  2. ArticleHow does diffraction reveal crystal plane spacing?
  3. ArticleHow do two-dimensional images reveal a particle’s three-dimensional shape?
  4. ArticleHow does an X-ray spectrum identify elements?
  5. ArticleHow do counts reveal neutrino oscillations?
  6. You are hereHow does the end of a beta spectrum constrain neutrino mass?
1 more group

Other articles that use the same experiments

Each experiment from this article that another series also uses, followed by the articles there.

  1. LabBeta Endpoint Mass Observatory
  2. ArticleWhere did the energy go? The puzzle that led to the neutrino
  3. ArticleKATRIN: limiting neutrino mass at the end of the beta spectrum
Something broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy