Forward resonant wavelength
Undulator period, electron energy and magnetic strength set resonance in this supplied one-dimensional paraxial model.
How can free electrons amplify light without atomic energy levels? Light modulates electron energies and gathers electrons into tiny groups that transfer kinetic energy to the wave. Amplification eventually saturates. Measuring a pumped sample also requires per-shot energy and timing references to distinguish its response from pulse width.
Follow energy modulation and microbunching through an undulator. Use the energy and timing record of each pulse to measure a pumped sample.
Current source model reference. Cyan: north; rust: south.
The blurred optical timing trace constrains a pulse kernel. It does not measure the X-ray phase or prove temporal coherence. An unresolved fast sample is not a measured zero lifetime.
The table condenses each frame; JSON and CSV retain every detector and timing pixel. Scroll sideways for calibrated results.
| Frame | Role | Pump | Trigger tick | Encoder code | Energy ADC | Pump ADC | Detector ADC sum | Timing first ADC | Stage delay / fs | Transmission | Standard uncertainty |
|---|
The apparatus shows a representative pump-on optical path. The protocol also includes pump-off controls.
| Terminal | Count or energy |
|---|
A prescribed optical relay is an external momentum reservoir. The account does not claim an isolated apparatus four-momentum balance.
Eight immutable records; 64 MiB decoded and 96 MiB text limits. Exports retain raw readings, units and independent calibrations. Invalid imports leave the session unchanged.
BackgroundAlternating magnets make electrons wiggle as light overtakes them. A suitable wave first modulates their energies, then gathers them into tiny groups.
Why it mattersThis interaction transfers electron kinetic energy into a short X-ray pulse. An experiment also needs to know the energy and sample arrival time of each pulse.
Undulator period, electron energy and magnetic strength set resonance in this supplied one-dimensional paraxial model.
Phase locates an electron relative to the wave. Scaled energy controls its advance, and the field changes that energy. Radiation slips toward the bunch head; energy leaving the finite window remains in the source account.
Positive carriage travel lengthens two path segments and delays the pump. An independent reference supplies time zero. Enlarged scene travel does not enter flight-time calculations.
The pulse-overlap curve and causal recovery determine each transmission. The measured blurred timing trace constrains that shot’s overlap; film response and optical blur retain their calibration uncertainty.
Typical misconceptionThe optical sample pump is the X-ray seed in the undulator.
Better mental modelThe resonant seed participates in X-ray amplification. The optical pump follows another route and excites the sample.
Typical misconceptionOne-femtosecond pixels imply a one-femtosecond lifetime measurement.
Better mental modelPixel pitch sets sampling. Pulse width, film response, blur and noise set resolving power, which known references must test.
Choose Seeded pulse and compare electron phase and energy distributions at different positions below the apparatus.
What to observe: Energy modulation develops into bunching. Field growth and electron energy loss come from the same interaction.Choose Into saturation and inspect the later part of the growth curve.
What to observe: Detuning and trapping slow radiation growth as the electron distribution continues to change.Choose Noise starts the field, then return to a seeded pulse.
What to observe: Physical electron number fixes the startup fluctuations. This short uniform-cell comparison reports mode power and bunching.Choose Probe arrives first or drag the delay carriage. Compare mirrors, path and transmission.
What to observe: Travel adds twice its distance to the optical route. Negative probe-minus-pump delay sends the probe through an unexcited sample.Choose Too fast to resolve and expand the timing trace, references and sample curve.
What to observe: Pulse and timing-film widths can blur a fast recovery. Insufficient resolution retains a bound and the original exposures.You are hereX-ray Free-Electron Laser