Skip to main content
Sandbox Physics

X-ray Free-Electron Laser

How can free electrons amplify light without atomic energy levels? Light modulates electron energies and gathers electrons into tiny groups that transfer kinetic energy to the wave. Amplification eventually saturates. Measuring a pumped sample also requires per-shot energy and timing references to distinguish its response from pulse width.

Follow energy modulation and microbunching through an undulator. Use the energy and timing record of each pulse to measure a pumped sample.

Interactive modelX-ray Free-Electron Laser

From electron groups to a changing sample

BackgroundAlternating magnets make electrons wiggle as light overtakes them. A suitable wave first modulates their energies, then gathers them into tiny groups.

Why it mattersThis interaction transfers electron kinetic energy into a short X-ray pulse. An experiment also needs to know the energy and sample arrival time of each pulse.

Focus question
How does light gather electrons and help measure a changing sample?
One-sentence intuition
Electron and field evolution produce gain. A sample response must be interpreted together with the width and timing of the pulse that measured it.

Core mathematical model

Forward resonant wavelength

λr=λu2γ2(1+K22)\lambda_r=\frac{\lambda_u}{2\gamma^2}\left(1+\frac{K^2}{2}\right)

Undulator period, electron energy and magnetic strength set resonance in this supplied one-dimensional paraxial model.

Coupled electron and field evolution

dθjdζ=pj,dpjdζ=−2Re⁡(Aeiθj),(∂ζ+∂s)A=n∑jwje−iθj\frac{d\theta_j}{d\zeta}=p_j,\qquad\frac{dp_j}{d\zeta}=-2\operatorname{Re}(Ae^{i\theta_j}),\qquad(\partial_\zeta+\partial_s)A=n\sum_j w_j e^{-i\theta_j}

Phase locates an electron relative to the wave. Scaled energy controls its advance, and the field changes that energy. Radiation slips toward the bunch head; energy leaving the finite window remains in the source account.

A carriage changes the optical route

ΔD=−2dc,D=tprobe−tpump\Delta D=-\frac{2d}{c},\qquad D=t_{\mathrm{probe}}-t_{\mathrm{pump}}

Positive carriage travel lengthens two path segments and delays the pump. An independent reference supplies time zero. Enlarged scene travel does not enter flight-time calculations.

Finite illumination and causal recovery

ri(D,τ)=∫0∞ki(D−u)e−u/τ dur_i(D,\tau)=\int_0^\infty k_i(D-u)e^{-u/\tau}\,du

The pulse-overlap curve and causal recovery determine each transmission. The measured blurred timing trace constrains that shot’s overlap; film response and optical blur retain their calibration uncertainty.

Common difficulties

Seed and pump have different jobs

Typical misconceptionThe optical sample pump is the X-ray seed in the undulator.

Better mental modelThe resonant seed participates in X-ray amplification. The optical pump follows another route and excites the sample.

Sampling and resolution

Typical misconceptionOne-femtosecond pixels imply a one-femtosecond lifetime measurement.

Better mental modelPixel pitch sets sampling. Pulse width, film response, blur and noise set resolving power, which known references must test.

Run the experiment

  1. 01

    Follow the tiny groups

    Choose Seeded pulse and compare electron phase and energy distributions at different positions below the apparatus.

    What to observe: Energy modulation develops into bunching. Field growth and electron energy loss come from the same interaction.
  2. 02

    Lengthen the interaction

    Choose Into saturation and inspect the later part of the growth curve.

    What to observe: Detuning and trapping slow radiation growth as the electron distribution continues to change.
  3. 03

    Compare a different start

    Choose Noise starts the field, then return to a seeded pulse.

    What to observe: Physical electron number fixes the startup fluctuations. This short uniform-cell comparison reports mode power and bunching.
  4. 04

    Send the probe through first

    Choose Probe arrives first or drag the delay carriage. Compare mirrors, path and transmission.

    What to observe: Travel adds twice its distance to the optical route. Negative probe-minus-pump delay sends the probe through an unexcited sample.
  5. 05

    Test temporal resolving power

    Choose Too fast to resolve and expand the timing trace, references and sample curve.

    What to observe: Pulse and timing-film widths can blur a fast recovery. Insufficient resolution retains a bound and the original exposures.

Related experiments and articles

What this page links to directly

How physics instruments measure · Reading path

How physics instruments measure

Articles on this path that use this experiment, followed by the other experiments they suggest.

  1. ArticleHow a free-electron laser gathers electrons into a brighter beam
Something broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy