Gaussian response width
Pulse widths are FWHM; jitter is RMS. The charge broadening coefficient is an assigned teaching parameter.
E49 · Electron acquisition
Record a delay series and unpumped reference, then fit a relaxation from camera counts while varying pulse charge and repeatability.
Physics tutorial
BackgroundRecord a delay series and unpumped reference, then fit a relaxation from camera counts while varying pulse charge and repeatability.
Why it mattersCan many gentle pulses reveal dynamics that one intense pulse blurs?
Start with the essentials
Pulse widths are FWHM; jitter is RMS. The charge broadening coefficient is an assigned teaching parameter.
Positive delay means the electron arrives after the pump at the specimen; the Gaussian has unit area.
The fixed 20 nm circular ROI and independently recorded unpumped image define the trace. The least-squares residual is descriptive, not an uncertainty on lifetime.
Typical misconceptionA small residual proves the physical experiment is fully resolved.
Better mental modelSynthetic 200 kV transmission-image model: a causal exponential feature is blurred by Gaussian pump, electron pulse and timing jitter. Space-charge temporal and spatial widths use disclosed assumed coefficients, not a Coulomb solver or instrument calibration. Each delay starts from an identically prepared fresh specimen. Stroboscopy then repeats that specimen; an irreversible preset retains a permanent state after its first pump. Single-shot uses one pulse at each delay on fresh replicas, not a movie of one irreversible event. Fits use a fixed camera ROI and recorded unpumped reference; they do not access the assigned lifetime. Shot noise, common-reference correlation and finite sampling remain; no CTF, diffraction, pulse compression, velocity mismatch, thermal accumulation or damage solver. Planes and beam paths are schematic.
Predict what increasing electrons per pulse does to counts and pulse widths.
What to observe: At fixed total electrons, many gentle pulses can avoid assigned space-charge blur.Record 31 delay frames and one unpumped reference; select a recorded frame.
What to observe: The camera carries real-space image counts, not a separately synthesized time plot.Commit a relaxation fit and inspect the count-derived trace and residual.
What to observe: The fitted amplitude absorbs spatial blur; the known response width comes from pulse calibration.Compare a single shot and an irreversible stroboscopic acquisition.
What to observe: Many counts cannot rescue a measurement that averages different specimen histories.