Skip to main content
Sandbox Physics

Two-Isotope Doppler Thermometer

How can two hydrogen isotopes give a gas temperature when the spectrometer also blurs the lines? Compare their line widths. At the same temperature the lighter hydrogen atoms move faster, so thermal motion broadens their line more than deuterium's, while the instrument blurs both equally. The difference of the two squared widths then depends only on temperature, and either line gives the instrument's share. If the instrument blur dominates, that small difference drowns in counting noise.

Record separate spectra of light and heavy hydrogen at the same temperature. Infer both Gaussian line widths from the photon counts, then split them into a thermal part and an instrument variance that both lines share.

Interactive modelTwo-Isotope Doppler Thermometer

Dispersed angles are enlarged.

Diffraction geometry

Normal incidence on a transmission grating; the first diffracted order reaches the rotating collection arm. Physical ray angles are unscaled. Fine scanning motion is tiny; sizes, bandwidth and slit widths are schematic.

Measure two widths before assigning a temperature.

Photon counts against calibrated vacuum wavelength

Two same-temperature samplesTransmission gratingWavelength bins + counts
Acquisition protocol

Two sequential scans retain 121 bins for each known isotope. Both samples share the same temperature and Gaussian instrument. Switching gas and acquisition are accelerated; no physical elapsed time is inferred.

Ready. Predict, then acquire.

Recorded bins

—\text{—}

Current analyser wavelength

—\text{—}

The lighter isotope gives a broader line.

Raw counts with a bin-integrated Poisson fit

(λ−λjref)/pm,Nj,i(\lambda-\lambda_j^{\rm ref})/\mathrm{pm},\quad N_{j,i}

Light isotopeHeavy isotopeSaved counts

Dots are observed photons per bin. Curves show the fitted profiles. Drag to inspect the nearest dots.

Recorded points and comparison curves

Dots retain zero bins; vertical bars show the square root of observed counts. Lines integrate over each bin. The optional gold source expectation is a simulation reference.

Thermal variance and instrumental blur

Infer from the recorded counts

Inferred temperature

—\text{—}

Inferred instrumental width

—\text{—}

Width-difference heuristic error

—\text{—}

No saved comparison.

Bars show observed variances. When inference is usable, gray is instrumental and green is thermal.

sj2,  σ^I2,  ajT^(pm2)s_j^2,\;\widehat\sigma_I^2,\;a_j\widehat T\quad(\mathrm{pm}^2)

Keep the discrepancies visible.

Model check against the kept counts

ri=sgn⁡(Ni−μi)Dir_i=\operatorname{sgn}(N_i-\mu_i)\sqrt{D_i}

Poisson deviance per bin defines the squared residual; its zero-count logarithm term is zero. Outliers beyond the plotting range appear as red edge dots. This plot checks the declared profile, not historical evidence. Fit boundaries and conservative identifiability rules can withhold the derived parameter.

Inspect the last eight raw bins
Sampleλleft/nm\lambda_{\rm left}/\mathrm{nm}λright/nm\lambda_{\rm right}/\mathrm{nm}NiN_i
Model, geometry and evidence

Incident light travels along the positive horizontal axis to a normal-incidence transmission grating. Its period is one micrometre, and the positive first order lies in the horizontal dispersion plane. The collection lens, slit and detector share that outgoing axis. The calibrated Gaussian bandpass is assumed, not derived from the exaggerated slit geometry.

dsin⁡β=λ,d=1000 nm,m=1d\sin\beta=\lambda,\quad d=1000\,\mathrm{nm},\quad m=1

Independent Poisson bins integrate the full line profile. The source budget is the ideal expected signal sum over a complete scan, apart from truncated tails; it is not an absolute radiometric calibration. Background is fitted from the same bins. Counts are synthetic, and recovery of their generating law is not an independent experimental test.

Known proton and deuteron masses plus the electron mass set the approximate atom masses. Both sources have one shared translational temperature and one shared instrumental width. Each real Balmer multiplet is collapsed to one effective line; applying this inversion directly to real hydrogen without resolving its components would bias temperature. The displayed error scale is a leading Gaussian count heuristic, not a fitted confidence interval or significance.

Two-Isotope Doppler Thermometer

BackgroundRecord separate spectra of light and heavy hydrogen at the same temperature. Infer both Gaussian line widths from the photon counts, then split them into a thermal part and an instrument variance that both lines share.

Why it mattersYou infer a constant from the observations you keep, read through a calibrated instrument response.

One-sentence intuition
Keep what the source is assumed to do separate from what you estimate from the recorded counts.

Core mathematical model

Thermal and instrument widths add as variances

sj2=σI2+ajT,aj=λj2kBmjc2s_j^2=\sigma_I^2+a_jT,\qquad a_j=\frac{\lambda_j^2 k_B}{m_jc^2}

Convolving two independent Gaussians adds their variances. The thermal broadening in wavelength uses the first-order Doppler approximation.

Two widths, two unknowns

T^=sH2−sD2aH−aD,σ^I2=sD2−aDT^\widehat T=\frac{s_H^2-s_D^2}{a_H-a_D},\qquad\widehat\sigma_I^2=s_D^2-a_D\widehat T

The estimate uses both measured widths. It is given neither the source temperature nor the instrument width.

Common difficulties

The simulation starts from the law

Typical misconceptionRecovering a source parameter independently confirms the law.

Better mental modelThese synthetic records test how the measurement and the inference work. They are not historical observations, they do not give a confidence interval for the parameter, and they are not outside scientific certification.

Run the experiment

  1. 01

    Compare two gases

    Acquire both isotope scans at the same source temperature.

    What to observe: The lighter atoms have a broader thermal line.
  2. 02

    Separate the instrument blur

    Increase only the source instrumental standard deviation and acquire again for comparison.

    What to observe: Both variances rise by the same amount, and their difference still carries the temperature.
  3. 03

    Check whether the temperature can still be found

    Choose the Instrument dominates preset.

    What to observe: A small difference between the two widths can be swamped by the counting uncertainty.

Related experiments and articles

What this page links to directly

See every article series on the content map →

Quantum evidence · Reading path

Laws and the formation of quantum mechanics

Articles on this path that use this experiment, followed by the other experiments they suggest.

  1. ArticleAtomic spectra: evidence for states, not photographs of orbits
  2. LabHydrogen–Deuterium Isotope SpectrometerMeasure an isotope shift
  3. LabHydrogen Orbitals & SpectraExplore hydrogen spectra
Something broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy