Skip to main content
Sandbox Physics

FINITE NUCLEAR MASS / LINE POSITIONS

Hydrogen–Deuterium Isotope Spectrometer

Resolve two ideal Balmer lines with a calibrated scanning grating analyser. Retain every photon-count bin, fit their separation and infer a continuous nuclear-mass ratio.

Interactive modelHydrogen–Deuterium Isotope Spectrometer

Normal incidence on a transmission grating; the first diffracted order reaches the rotating collection arm. Physical ray angles are unscaled. Fine scanning motion is tiny; sizes, bandwidth and slit widths are schematic.

CALIBRATED VACUUM WAVELENGTH / PHOTON COUNTS

Count both peaks before assigning a mass.

Mixed isotope sourceTransmission gratingWavelength bins + counts

One scan retains 181 equal-width bins. A common fitted Gaussian response acts on two ideal effective Balmer lines. Changing the upper level changes the vacuum wavelength and isotope separation.

Ready. Predict, then acquire.

Recorded bins

—\text{—}

Current analyser wavelength

—\text{—}

RAW COUNTS / BIN-INTEGRATED POISSON FIT

A small shift records a moving nucleus.

(λ−λHref)/pm,Ni(\lambda-\lambda_H^{\rm ref})/\mathrm{pm},\quad N_i

Retained countsFitted doubletSaved counts

Dots retain zero bins; vertical bars show the square root of observed counts. Lines integrate over each bin. The optional gold source expectation is a simulation reference.

INFER FROM THE RETAINED COUNTS

One displacement. A continuous mass.

Inferred heavy/light nuclear mass

—\text{—}

Fitted wavelength separation

—\text{—}

Fitted common width

—\text{—}

No saved comparison.

Green: fitted light component. Brown: fitted heavy component.

λ−λHref  (pm),N^j,i\lambda-\lambda_H^{\rm ref}\;(\mathrm{pm}),\quad \widehat N_{j,i}

MODEL CHECK / RETAINED COUNTS

Keep the discrepancies visible.

ri=sgn⁡(Ni−μi)Dir_i=\operatorname{sgn}(N_i-\mu_i)\sqrt{D_i}

Poisson deviance per bin defines the squared residual; its zero-count logarithm term is zero. Outliers beyond the plotting range appear as red edge dots. This plot checks the declared profile, not historical evidence. Fit boundaries and conservative identifiability rules can withhold the derived parameter.

Inspect the last eight raw bins
Sampleλleft/nm\lambda_{\rm left}/\mathrm{nm}λright/nm\lambda_{\rm right}/\mathrm{nm}NiN_i
Model, geometry and evidence

Incident light travels along the positive horizontal axis to a normal-incidence transmission grating. Its period is one micrometre, and the positive first order lies in the horizontal dispersion plane. The collection lens, slit and detector share that outgoing axis. The calibrated Gaussian bandpass is assumed, not derived from the exaggerated slit geometry.

dsin⁡β=λ,d=1000 nm,m=1d\sin\beta=\lambda,\quad d=1000\,\mathrm{nm},\quad m=1

Independent Poisson bins integrate the full line profile. The source budget is the ideal expected signal sum over a complete scan, apart from truncated tails; it is not an absolute radiometric calibration. Background is fitted from the same bins. Counts are synthetic, and recovery of their generating law is not an independent experimental test.

The lighter nucleus is a known proton. The heavy nucleus is continuously tunable near deuterium; the estimator does not impose its expected ratio. Both ideal unbroadened lines have the same fitted instrumental width. Thermal broadening is omitted in this protocol.

Physics tutorial

Hydrogen–Deuterium Isotope Spectrometer

BackgroundResolve two ideal Balmer lines with a calibrated scanning grating analyser. Retain every photon-count bin, fit their separation and infer a continuous nuclear-mass ratio.

Why it mattersA constant is inferred through a calibrated response and retained observations.

Start with the essentials

Focus question
The nucleus moves too.
One-sentence intuition
Keep source assumptions separate from estimates made from records.

Core mathematical model

Reduced mass

RM=R∞1+me/M,λM−1=RM(14−1n2)R_M=\frac{R_\infty}{1+m_e/M},\qquad\lambda_M^{-1}=R_M\left(\frac14-\frac1{n^2}\right)

Vacuum wavelengths from the nonrelativistic Coulomb model. Fine structure is omitted.

Invert the separation

r=MDMH=[1−ΔλλH1+ηη]−1,η=meMHr=\frac{M_D}{M_H}=\left[1-\frac{\Delta\lambda}{\lambda_H}\frac{1+\eta}{\eta}\right]^{-1},\quad\eta=\frac{m_e}{M_H}

The fitted light-line center and positive separation enter the inversion; the source mass and mixture do not.

Common difficulties

A simulation supplies its law

Typical misconceptionRecovering a source parameter independently confirms the law.

Better mental modelThese synthetic records test a measurement and inference workflow. They are not historical observations, a parameter confidence interval, or external scientific certification.

Run the experiment

  1. 01

    Predict the sign

    Increase the heavy nuclear mass before acquiring.

    What to observe: The heavy line moves to shorter wavelength.
  2. 02

    Retain the scan

    Acquire all bins, including zeros. Save the run and export CSV.

    What to observe: Moving the analyser probe leaves the recorded spectrum intact.
  3. 03

    Lose resolution

    Compare the blended-pair preset with the resolved pair.

    What to observe: A low residual alone does not make two masses identifiable.
FeedbackSomething broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy