Line positions with the reduced mass
The formula gives vacuum wavelengths from the nonrelativistic Coulomb model, without fine structure.
Finite nuclear mass / Line positions
Why do hydrogen and deuterium emit their spectral lines at slightly different wavelengths? Because the nucleus is not infinitely heavy. Electron and nucleus both circle their common center of mass, so the levels depend on a reduced mass slightly below the electron mass. Deuterium's heavier nucleus moves less, its levels spread a little wider, and each line shifts to shorter wavelength by about 0.03 percent. With the lines resolved, that gap gives the ratio of the two nuclear masses.
Separate two ideal Balmer lines with a calibrated scanning grating analyser. Keep every bin of photon counts, fit the spacing between the lines and infer the nuclear-mass ratio, which can take any value.
Normal incidence on a transmission grating; the first diffracted order reaches the rotating collection arm. Physical ray angles are unscaled. Fine scanning motion is tiny; sizes, bandwidth and slit widths are schematic.
Photon counts against calibrated vacuum wavelength
One scan keeps 181 equal-width bins. Both ideal effective Balmer lines are blurred by the same fitted Gaussian response. Changing the upper level changes the vacuum wavelength and the isotope separation.
Ready. Predict, then acquire.
Recorded bins
Current analyser wavelength
Raw counts with a bin-integrated Poisson fit
Dots retain zero bins; vertical bars show the square root of observed counts. Lines integrate over each bin. The optional gold source expectation is a simulation reference.
Infer from the recorded counts
Inferred heavy/light nuclear mass
Fitted wavelength separation
Fitted common width
No saved comparison.
Green: fitted light component. Brown: fitted heavy component.
Model check against the kept counts
Poisson deviance per bin defines the squared residual; its zero-count logarithm term is zero. Outliers beyond the plotting range appear as red edge dots. This plot checks the declared profile, not historical evidence. Fit boundaries and conservative identifiability rules can withhold the derived parameter.
| Sample |
|---|
Incident light travels along the positive horizontal axis to a normal-incidence transmission grating. Its period is one micrometre, and the positive first order lies in the horizontal dispersion plane. The collection lens, slit and detector share that outgoing axis. The calibrated Gaussian bandpass is assumed, not derived from the exaggerated slit geometry.
Independent Poisson bins integrate the full line profile. The source budget is the ideal expected signal sum over a complete scan, apart from truncated tails; it is not an absolute radiometric calibration. Background is fitted from the same bins. Counts are synthetic, and recovery of their generating law is not an independent experimental test.
The lighter nucleus is a known proton. The heavy nucleus is continuously tunable near deuterium; the estimator does not impose its expected ratio. Both ideal unbroadened lines have the same fitted instrumental width. Thermal broadening is omitted in this protocol.
NIST · Atomic spectroscopyTel Aviv · Isotope spectroscopyNIST · Doppler thermometry
Next: infer a temperatureHydrogen orbitals and transitionsHistorical spectral evidence
Physics tutorial
BackgroundSeparate two ideal Balmer lines with a calibrated scanning grating analyser. Keep every bin of photon counts, fit the spacing between the lines and infer the nuclear-mass ratio, which can take any value.
Why it mattersYou infer a constant from the observations you keep, read through a calibrated instrument response.
Start with the essentials
The formula gives vacuum wavelengths from the nonrelativistic Coulomb model, without fine structure.
Only the fitted center of the light line and the positive line spacing go into the inversion. The source mass and the isotope mixture do not.
Typical misconceptionRecovering a source parameter independently confirms the law.
Better mental modelThese synthetic records test how the measurement and the inference work. They are not historical observations, they do not give a confidence interval for the parameter, and they are not outside scientific certification.
Raise the source heavy/light nuclear mass before you acquire.
What to observe: The heavy line moves to shorter wavelength.Acquire every wavelength bin, including those with zero counts. Save the run and export the CSV.
What to observe: Moving the analyser probe does not change the recorded spectrum.Compare the Blended pair preset with Resolved pair.
What to observe: A small residual alone does not mean the two masses can be told apart.Quantum evidence · Reading path
Articles on this path that use this experiment, followed by the other experiments they suggest.