Reduced mass
Vacuum wavelengths from the nonrelativistic Coulomb model. Fine structure is omitted.
FINITE NUCLEAR MASS / LINE POSITIONS
Resolve two ideal Balmer lines with a calibrated scanning grating analyser. Retain every photon-count bin, fit their separation and infer a continuous nuclear-mass ratio.
Normal incidence on a transmission grating; the first diffracted order reaches the rotating collection arm. Physical ray angles are unscaled. Fine scanning motion is tiny; sizes, bandwidth and slit widths are schematic.
CALIBRATED VACUUM WAVELENGTH / PHOTON COUNTS
One scan retains 181 equal-width bins. A common fitted Gaussian response acts on two ideal effective Balmer lines. Changing the upper level changes the vacuum wavelength and isotope separation.
Ready. Predict, then acquire.
Recorded bins
Current analyser wavelength
RAW COUNTS / BIN-INTEGRATED POISSON FIT
Dots retain zero bins; vertical bars show the square root of observed counts. Lines integrate over each bin. The optional gold source expectation is a simulation reference.
INFER FROM THE RETAINED COUNTS
Inferred heavy/light nuclear mass
Fitted wavelength separation
Fitted common width
No saved comparison.
Green: fitted light component. Brown: fitted heavy component.
MODEL CHECK / RETAINED COUNTS
Poisson deviance per bin defines the squared residual; its zero-count logarithm term is zero. Outliers beyond the plotting range appear as red edge dots. This plot checks the declared profile, not historical evidence. Fit boundaries and conservative identifiability rules can withhold the derived parameter.
| Sample |
|---|
Incident light travels along the positive horizontal axis to a normal-incidence transmission grating. Its period is one micrometre, and the positive first order lies in the horizontal dispersion plane. The collection lens, slit and detector share that outgoing axis. The calibrated Gaussian bandpass is assumed, not derived from the exaggerated slit geometry.
Independent Poisson bins integrate the full line profile. The source budget is the ideal expected signal sum over a complete scan, apart from truncated tails; it is not an absolute radiometric calibration. Background is fitted from the same bins. Counts are synthetic, and recovery of their generating law is not an independent experimental test.
The lighter nucleus is a known proton. The heavy nucleus is continuously tunable near deuterium; the estimator does not impose its expected ratio. Both ideal unbroadened lines have the same fitted instrumental width. Thermal broadening is omitted in this protocol.
NIST · Atomic spectroscopyTel Aviv · Isotope spectroscopyNIST · Doppler thermometry
Next: infer a temperatureHydrogen orbitals and transitionsHistorical spectral evidence
Physics tutorial
BackgroundResolve two ideal Balmer lines with a calibrated scanning grating analyser. Retain every photon-count bin, fit their separation and infer a continuous nuclear-mass ratio.
Why it mattersA constant is inferred through a calibrated response and retained observations.
Start with the essentials
Vacuum wavelengths from the nonrelativistic Coulomb model. Fine structure is omitted.
The fitted light-line center and positive separation enter the inversion; the source mass and mixture do not.
Typical misconceptionRecovering a source parameter independently confirms the law.
Better mental modelThese synthetic records test a measurement and inference workflow. They are not historical observations, a parameter confidence interval, or external scientific certification.
Increase the heavy nuclear mass before acquiring.
What to observe: The heavy line moves to shorter wavelength.Acquire all bins, including zeros. Save the run and export CSV.
What to observe: Moving the analyser probe leaves the recorded spectrum intact.Compare the blended-pair preset with the resolved pair.
What to observe: A low residual alone does not make two masses identifiable.