Resolved sidebands
The red sideband removes one phonon and the blue sideband adds one. Detuning is measured from the selected transition. The carrier changes only the internal state.
Why does the red sideband disappear when a trapped ion reaches its motional ground state? Driving the red sideband takes one quantum of motion away from the ion, so it fails once the ion is in its motional ground state: there is nothing left to take. The blue sideband adds a quantum and still works. Comparing the two sideband strengths over many repeated measurements tells you how cold the motion is.
Drive a trapped ion on either side of its resonance and compare many repeated readings of its internal state. Then use cooling pulses to remove its motion one quantum at a time.
How can an alternating field store an ion and then send it to a detector? The changing quadrupole field can keep the motion bounded. Auxiliary excitation or an RF amplitude ramp can then make that motion grow until the ion passes an exit. Actual collector arrivals, compared with independently known ions under the same preparation, give mass-to-charge intervals.
Follow finite ion paths through the rod slots. Compare resonant excitation with an RF mass scan and inspect the standards alongside the collected events.
Red: red sideband. Blue: blue sideband. Gray: selected transition. Dots and 95% Wilson bars: recorded outcomes.
Drag to inspect any probe duration. Autoplay repeats the early model response without taking measurements.
Mean motional occupation after preparation · model
Thermal estimate · from paired counts
Acquire a comparison to fill the table. The table keeps the settings it was taken with, even if you change the controls.
| Probe | Read / total | Excited |
|---|
Ideal binary state discrimination when available; unread trials are retained. No fluorescence photon arrival stream is simulated. Every trial uses an independent preparation. Model number distributions are not reconstructed from these binary counts.
The motion starts in a thermal state of one effective harmonic mode. The carrier and first-sideband dynamics assume resolved transitions. The trap frequency is fixed at twenty inverse reference times. Cooling uses resonant red pulses and a perfect, recoil-free reset, so the cooled distribution is generally not thermal.
The sideband and cavity protocols use an arbitrary reference time unit. The separate RF protocol below uses physical SI units. Geometry is schematic, with enlarged atoms and mode envelopes.
The apparatus dial sets the same model carrier drive as the slider; pulse area also depends on probe duration. Its angle is a user interface, with no manufacturer power calibration. Moving the view does not change trap or spectroscopy calibration.
Primary sources: Leibfried et al. · 2003 · Vybornyi et al. · 2023
Integrate one classical test ion in a declared linear quadrupole. The stability map tests the ideal equations; the trajectory tests only this launch for this observation time. Neither establishes capture.
Captured Mathieu parameters
Position · simulated coordinate
Radial monodromy trace
Within-period radial residual RMS
Blue: integrated radial coordinate. Amber: complete-period means. The residual includes secular change within a period; it is not a unique intrinsic/excess micromotion separation.
Blue: both radial axes and axial motion bounded. Red: unstable. Gray: boundary or degenerate. The marker uses the captured voltages; the grid is a numerical section, not an electrode acceptance map.
Positive charge; mass 40 atomic mass units. Radial scale 0.5 mm; axial scale 1 mm; endcap factor 0.2. Coordinates form a right-handed frame: axial points along the rods; the radial pair points upward and across the stage. Geometry is schematic; ion displacement is enlarged tenfold relative to the electrode schematic. The 200 µm axial limit and adjustable radial cylinder are absorbing diagnostic boundaries inside the near-axis field, not electrode surfaces.
Velocity Verlet uses 192 steps per RF period; the Floquet matrix uses independent RK4 integration. Trace within a numerical tolerance of either boundary is withheld as marginal, including free drift. Escape time is bracketed by adjacent integration steps. Survival is finite and depends on initial energy, phase and aperture. No cooling, gas collision, space charge, electrode anharmonicity, stray fields or dissipative loading is modeled.
This classical RF protocol and the harmonic quantum sideband protocol are separate experiments. Changing the RF fields does not recalibrate the sideband frequency and does not produce spectroscopy counts. All coordinates here are simulated, not detected ion positions.
Berkeland et al. · 1998 · equations 1–6 (NIST collection) · Wineland et al. · linear trap and sideband manipulation
Inside the checked 32–48 domain, this observation supports a 36–40 window. Overlapping windows do not determine the number of species.
Exports include every reference, applied preparation command, voltage readback, birth and pulse timestamp, field version, lineage and retained trajectory. Reset changes the apparatus settings and keeps older captures.
BackgroundA two-level system can exchange energy with a quantized oscillator.
Why it mattersChange how the system is prepared, then test the model against many independent state readings.
The red sideband removes one phonon and the blue sideband adds one. Detuning is measured from the selected transition. The carrier changes only the internal state.
The motion starts in a thermal distribution. Cooling updates the probability of every phonon number; the result is never replaced by a fitted thermal state.
The model keeps the full displacement matrix element for an isolated first sideband. At small displacement it approaches the square-root dependence on phonon number.
Each state reading is a new Bernoulli trial. A red-sideband drive cannot excite an ion in its motional ground state.
This works only for a thermal single-mode state probed with matched pulses. The point estimate is hidden after cooling, or when the two pointwise Wilson intervals overlap. That rule is not a confidence interval for the occupation.
Typical misconceptionThe glowing object traces the path of a single particle.
Better mental modelThe fixed marker only shows where the particle sits. Brightness shows a probability or a mean occupation. Only the recorded tiles are actual samples.
Typical misconceptionThis is a calibrated real apparatus.
Better mental modelThe sideband experiment uses a harmonic pseudopotential, resolved transitions and an ideal cooling reset with no recoil. The separate classical RF experiment follows the driven motion and the loss through a finite aperture, but its fields do not recalibrate the sideband model. Neither mode simulates the stream of arriving photons or the actual loading of the trap.
Try motion in the ground state, then warm motion.
What to observe: The whole response curve changes between the two cases.Drag the time cursor and read out 200 fresh preparations.
What to observe: The preview never produces data by itself.Acquire a matched pair of red and blue sideband readings.
What to observe: You can export the raw CSV and recompute the state frequencies yourself. Saved comparisons keep the settings they were taken with.Read the instrument principle, sources and limits
BackgroundFour rods rapidly reverse the transverse field, while endcaps confine the axial direction. A positive ion oscillates near the centre and remains inside a finite volume.
Why it mattersA trapped ion must also be released selectively. Auxiliary resonance and increasing RF amplitude can grow its motion until it produces a collector pulse.
Positions are in metres, time in seconds and charge in coulombs. Time-dependent electrodes exchange energy with the ion. Actual material surfaces terminate a colliding trajectory.
RF voltage is the zero-to-peak difference between opposite rod pairs. The ideal near-axis potential uses that voltage times the transverse squared-coordinate difference divided by twice the field-radius squared. The other transverse Mathieu parameter has the opposite sign. The finite field also includes slots, endcaps and housing.
This small-parameter approximation includes the constant field's local curvature in this expression. Fast micromotion rides on the slow oscillation. A voltage scan approaching instability requires the full time-dependent field and an actual collector trajectory to establish the detection time.
Recorded counters and an independent clock standard supply elapsed time. Actual known-ion windows calibrate mass intervals, and different withheld ions test them. Each pulse shares the same reference error, which remains at the mass-window endpoints.
Typical misconceptionCrossing the opening counts an ion.
Better mental modelThe ion can return to the trap or strike the negative dump. Only a terminal event at the positive collector front enters the counter.
Typical misconceptionTwo coloured mass windows identify two molecular species.
Better mental modelTouching or overlapping windows do not determine species count. Different masses and charge states can share a mass-to-charge ratio. This model reports finite conditional intervals and the counts of actual collector hits.
Compare the whole trap with the ion closeup, then pause and change initial RF amplitude.
What to observe: Fast RF motion rides on a slower oscillation. Holding the gold feed knob changes the real reference field; the data plots keep the last acquisition.Compare resonant excitation, AC off and the default RF mass scan.
What to observe: A suitable auxiliary drive grows the oscillation. The default measurement increases RF amplitude until the actual trajectory leaves the trap. Both must continue to the collector to create a count.Use the rod-opening and collector views.
What to observe: An opening permits further flight. The positive collector front registers a pulse; the grounded negative dump registers a loss. The default mirror attempts start 200 microseconds apart, after the complete previous gate.Compare the default window, controlled mixed exposures and the broad mixed source.
What to observe: Each collected event supplies a compatible interval. Windows widen near a reference anchor. A broad source changes the ejection-time distribution and can retain pulses while mass interpretation stops.Export JSON or CSV, change settings, reset and import the earlier archive.
What to observe: Readbacks, birth times, scans, pulse timestamps and references remain attached to each acquisition. Reset changes the apparatus settings; a new acquisition integrates fresh finite trajectories.You are hereTrapped-Ion Sideband Spectroscopy
Quantum evidence · Reading path
Articles on this path that use this experiment, followed by the other experiments they suggest.
How physics instruments measure · Reading path
Articles on this path that use this experiment, followed by the other experiments they suggest.