Skip to main content
Sandbox Physics

A logic ion reports the state of a spectroscopy ion

Two-Ion Quantum Logic Spectroscopy

How can you take the spectrum of one ion by watching the light from another ion beside it? Through the motion the two ions share in one trap. After the probe laser tries to excite the first ion, one pulse turns any excitation into a quantum of that shared vibration, and a second pulse hands it to the other ion, whose fluorescence shows whether it arrived. Repeating this at each probe frequency traces out the first ion's line. If the vibration is lost between pulses, the line fades.

Excite the spectroscopy ion, pass its excitation through one shared quantum of motion to the logic ion, and count the logic ion's fluorescence. Calibrate the bright and dark counts first, then find the center of the line.

Interactive modelTwo-Ion Quantum Logic Spectroscopy

The trap axis joins the two ions. The two ions and their separation are enlarged. Sideband beams address the ions in sequence; shared motion is not a photon traveling between them. The objective collects only auxiliary-ion fluorescence toward the counter. Sequence colors show source population expectations, not a measured trajectory.

Reproducible synthetic observations

A spectrum read through the auxiliary ion.

Ready to collect simulated data.

A new run starts with 64 preparations known to be bright and 64 known to be dark, then an interleaved scan over 41 frequencies. Each trial records the detected photon count, not a hidden label for the ion’s state. The spectral estimator does not use the source line shift, sideband pulse areas, delay or source photon means. The acquisition is sped up.

Retained data

Individual fluorescence counts.

i,ndeti,\quad n_{\rm det}

First 240 scan trials, excluding calibration. Green: current detected counts. Gray: exact saved counts. The inspection control selects one of these trials; the full run remains in CSV.

Estimates from the records

Claim only what the measurement supports

Fitted spectral center

—\text{—}

Transferred population amplitude

—\text{—}

Measured bright / dark mean photons

—\text{—}

Calibrated false / true dark fractions

—\text{—}

Inspected photon count

—\text{—}

On-resonance source populations · spectroscopy / motion / logic

—\text{—}

No line center is reported if the acquisition is incomplete, the references overlap, the transferred response is weak or the fit lands at the edge of the search range. The profile is a relative likelihood diagnostic, not a calibrated confidence interval.

Data reduction

Calibrated dark fractions and fitted line.

δ/kHz,q^D\delta/\mathrm{kHz},\quad\widehat q_D

Green points: classified dark fraction; brown line: response fitted from these counts with calibrated classification rates. No source center is drawn as a measurement.

Center likelihood profile.

δ0/kHz,2(ℓmax⁡−ℓ)\delta_0/\mathrm{kHz},\quad 2(\ell_{\max}-\ell)

At each candidate center the transfer amplitude is optimized again. The plot caps the relative deviance at forty.

Last eight raw records

Columns: index, preparation, probe detuning in kilohertz, detected photons.

IndexPreparationDetuningPhotons

Model and sources

Both ions are synthetic two-level systems that share one motional mode, which starts cold. The red-sideband pulses are coherent, phonon loss uses an illustrative channel, and trapping and preparation are ideal. The Lab does not solve for the RF electrode field, leaves out thermal modes, spontaneous decay and clock systematics, and makes no precision claim. The fluorescence spectrum shows how much population was transferred, not coherence or transfer fidelity. The enlarged apparatus and the pulse animation are schematic.

Excitation by a rectangular pulse

Pe(δ)=Ω2Ω2+Δ2⋅sin⁡2 ⁣(TΩ2+Δ22)Δ=2π(δ−δ0),ΩT=π\begin{aligned}P_e(\delta)&=\frac{\Omega^2}{\Omega^2+\Delta^2}\\&\quad\cdot\sin^2\!\left(\frac{T\sqrt{\Omega^2+\Delta^2}}2\right)\\\Delta&=2\pi(\delta-\delta_0),\quad\Omega T=\pi\end{aligned}

In the formula, detunings are frequencies in hertz; the scan axis shows kilohertz. The probe duration is calibrated and supplied as a known input.

Passing the excitation to the logic ion

∣eSgL0⟩⟶∣gSgL1⟩⟶∣gSeL0⟩\begin{aligned}|e_Sg_L0\rangle&\longrightarrow|g_Sg_L1\rangle\\&\longrightarrow|g_Se_L0\rangle\end{aligned}

Two resonant red-sideband pulses pass the excitation through the shared motional mode. If the spectroscopy ion was not excited, nothing changes. The source evolution shown on screen is computed with a density matrix.

How much population is transferred

A=sin⁡4(θ/2) e−td/τmPL,e=A Pe,τm=1 ms\begin{aligned}A&=\sin^4(\theta/2)\,e^{-t_d/\tau_m}\\P_{L,e}&=A\,P_e,\quad\tau_m=1\,\mathrm{ms}\end{aligned}

Between the pulses, an illustrative zero-temperature amplitude-damping channel acts on the motional mode. Its lifetime is a chosen parameter, not a value measured on an apparatus.

Probability of a dark reading

qD(δ)=fB+(fD−fB) A^ Pe(δ)\begin{aligned}q_D(\delta)&=f_B+(f_D-f_B)\,\widehat A\,P_e(\delta)\end{aligned}

Counts from known bright and dark references set the threshold and the two classification rates. A binomial likelihood then fits the line center and the transfer amplitude to the scan counts. The source shift and pulse areas are not given to the fit.

Three-Photon GHZ Correlation Bench

Physics tutorial

Two-Ion Quantum Logic Spectroscopy

BackgroundExcite the spectroscopy ion, pass its excitation through one shared quantum of motion to the logic ion, and count the logic ion's fluorescence. Calibrate the bright and dark counts first, then find the center of the line.

Why it mattersA measurement protocol is the chain of steps that links a prepared quantum system to the detector counts you keep.

Start with the essentials

Focus question
How can you take the spectrum of one ion by watching the light from another ion beside it?
One-sentence intuition
Keep what is assumed about the source apart from what is estimated from the recorded data.

Core mathematical model

Excitation by a rectangular pulse

Pe(δ)=Ω2Ω2+Δ2⋅sin⁡2 ⁣(TΩ2+Δ22)Δ=2π(δ−δ0),ΩT=π\begin{aligned}P_e(\delta)&=\frac{\Omega^2}{\Omega^2+\Delta^2}\\&\quad\cdot\sin^2\!\left(\frac{T\sqrt{\Omega^2+\Delta^2}}2\right)\\\Delta&=2\pi(\delta-\delta_0),\quad\Omega T=\pi\end{aligned}

In the formula, detunings are frequencies in hertz; the scan axis shows kilohertz. The probe duration is calibrated and supplied as a known input.

Passing the excitation to the logic ion

∣eSgL0⟩⟶∣gSgL1⟩⟶∣gSeL0⟩\begin{aligned}|e_Sg_L0\rangle&\longrightarrow|g_Sg_L1\rangle\\&\longrightarrow|g_Se_L0\rangle\end{aligned}

Two resonant red-sideband pulses pass the excitation through the shared motional mode. If the spectroscopy ion was not excited, nothing changes. The source evolution shown on screen is computed with a density matrix.

How much population is transferred

A=sin⁡4(θ/2) e−td/τmPL,e=A Pe,τm=1 ms\begin{aligned}A&=\sin^4(\theta/2)\,e^{-t_d/\tau_m}\\P_{L,e}&=A\,P_e,\quad\tau_m=1\,\mathrm{ms}\end{aligned}

Between the pulses, an illustrative zero-temperature amplitude-damping channel acts on the motional mode. Its lifetime is a chosen parameter, not a value measured on an apparatus.

Probability of a dark reading

qD(δ)=fB+(fD−fB) A^ Pe(δ)\begin{aligned}q_D(\delta)&=f_B+(f_D-f_B)\,\widehat A\,P_e(\delta)\end{aligned}

Counts from known bright and dark references set the threshold and the two classification rates. A binomial likelihood then fits the line center and the transfer amplitude to the scan counts. The source shift and pulse areas are not given to the fit.

Common difficulties

A simulation already contains its law

Typical misconceptionRecovering a source parameter from the data is an independent check of the law.

Better mental modelThese synthetic records test how the measurement and the inference work. They are not historical observations, they give no confidence interval for the parameter, and they are not external scientific certification.

Run the experiment

  1. 01

    Calibrate, then scan

    Acquire a complete run and export the raw photon counts.

    What to observe: The first 128 records alternate between known bright and dark preparations. The scan over 41 probe frequencies comes after them.
  2. 02

    Interrupt the transfer

    Save a comparison. Then choose Mapping off, or add delay between the mappings.

    What to observe: The logic ion's fluorescence spectrum loses its contrast, even though the probe still excites the spectroscopy ion in the source model.
  3. 03

    Separate population and coherence

    Step through the sequence stages, then look at the fluorescence calibration.

    What to observe: The stage populations are predictions of the source model. The recorded photon counts can only tell you about populations. Testing whether coherence was transferred would need a Ramsey protocol.

Related experiments and articles

Quantum evidence · Reading path

Clocks, traps and single-quantum control

Articles on this path that use this experiment, followed by the other experiments they suggest.

  1. ArticleLet a second ion read out a narrow transition
  2. LabTrapped-Ion Sideband SpectroscopySee how a sideband pulse moves an excitation into the motion
  3. LabRamsey Frequency MeasurementCompare reading out the level with reading out the phase
  4. LabQuantum State & Process TomographyFind out which measurements test coherence
FeedbackSomething broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy