Skip to main content
Sandbox Physics

Synchrotron and Storage Ring

How can defocusing help confine a beam, and how do pickups guide an orbit correction? A magnet changes the position and angle seen by the next one. Suitable alternating strengths and spacing keep both transverse oscillations bounded. Turn-by-turn pickups and small measured steering steps then reveal how to correct the orbit.

Track a proton bunch through FODO magnets. Calibrate pickups, measure tune aliases and steering response, then observe a corrected orbit.

Interactive modelSynchrotron and Storage Ring

Synchrotron and Storage Ring

BackgroundTrack a proton bunch through FODO magnets. Calibrate pickups, measure tune aliases and steering response, then observe a corrected orbit.

Why it mattersEach quadrupole focuses one plane and defocuses the other. The next magnet acts after the particles have moved. Follow that change, then ask how electrode signals can guide a correction.

Focus question
Which ring settings confine the bunch, and which steering changes do the recorded pickups support?
One-sentence intuition
Position and angle must travel together. The orbit estimate comes from calibrated electrodes and measured scans; the propagated beam width is a separate model prediction.

Core mathematical model

The two planes respond differently

x′′+(h2+k)x=hδy′′−ky=0,δ=(p−p0)/p0\begin{aligned}x''+(h^2+k)x&=h\delta\\y''-ky&=0,\quad\delta=(p-p_0)/p_0\end{aligned}

The positive horizontal coordinate points outward and vertical points upward. Positive k focuses horizontally. Sector bends have curvature h. Only first-order transverse and momentum terms are retained.

Particle and beam matrix share transport

zj+1=Mjzj+djδ,Σj+1=MjΣjMjTz_{j+1}=M_jz_j+d_j\delta,\qquad\Sigma_{j+1}=M_j\Sigma_jM_j^{\mathsf T}

The finite particle group and its covariance use the same thick-element map before losses. The homogeneous transverse matrix preserves the symplectic form. After clipping, surviving-particle moments are computed separately.

Calibrate position before averaging turns

rx=VR−VLVR+VL,x=Kxrx+xoffr_x=\frac{V_R-V_L}{V_R+V_L},\qquad x=K_xr_x+x_{\rm off}

Independent voltage and wire-position standards determine the gains, pedestal, position scale and offset. Every electrode and position is checked against its own supported range. A low unresolved sum gives no position.

A sampled tune has aliases

xn=c+acos⁡(2πqn)+bsin⁡(2πqn),q↔1−qx_n=c+a\cos(2\pi qn)+b\sin(2\pi qn),\qquad q\leftrightarrow1-q

The constant c separates the average orbit from undamped motion. Actual turn indices are retained. Once-per-turn real data cannot select an integer tune; every-other-turn data creates more aliases.

Measure the response and observe again

Di=∂xˉi∂δ,Rij=∂xˉi∂θj,Δxˉ≃RΔθD_i=\frac{\partial\bar x_i}{\partial\delta},\qquad R_{ij}=\frac{\partial\bar x_i}{\partial\theta_j},\qquad\Delta\bar x\simeq R\Delta\theta

Independent momentum preparations measure dispersion. Positive and negative measured steering steps determine response columns, with a separate mixed-step check. A rank-supported solve is executed and tested with a fresh exposure. Shared calibration errors remain correlated.

Common difficulties

A narrow spot is not a whole-ring condition

Typical misconceptionThe smallest beam spot means the whole ring is stable.

Better mental modelPosition and angle evolve together. A crossing spot may expand downstream; stability concerns repeated transport around the complete lattice.

More turns do not erase a common zero

Typical misconceptionAveraging many turns removes all position error.

Better mental modelIndependent pickup noise can average down. The same calibration zero affects every turn and remains in the orbit and command uncertainty.

Run the experiment

  1. 01

    Predict the missing family

    Compare Stable FODO and Missing defocusing family. Inspect the quadrupole view and the physical loss marker.

    What to observe: Both coordinates stay bounded in the stable lattice. Removing one family lets an excursion reach the physical pipe. The raw observations already taken remain available.
  2. 02

    Separate an orbit from oscillation

    Compare the baseline turn trace with Momentum scan. Select the independent negative and positive momentum platforms in the raw table.

    What to observe: A fitted constant estimates the orbit without adding damping. The slope uses measured momentum readbacks and a withheld preparation, not a hidden model dispersion.
  3. 03

    Use a measured adjustment

    Choose Measure and correct, then compare before and newly observed residuals with the measured response map. Drag the first corrector control and acquire a fresh scan.

    What to observe: The controller uses the scanned response and actual actuator limits. A new exposure decides whether the proposed correction improved the observed orbit. Reset starts another experiment and keeps saved history.
  4. 04

    Keep an unresolved observation

    Compare Every other turn and Weak pickup signal. Export JSON or CSV, import it and select the same record.

    What to observe: Missing turns preserve their indices and extra aliases. Weak signals retain codes while unsupported position or response stays unreported. Rebuilding does not replace the archived signals.

Related experiments and articles

What this page links to directly

You are hereSynchrotron and Storage Ring

Articles

How physics instruments measure · Reading path

How physics instruments measure

Articles on this path that use this experiment, followed by the other experiments they suggest.

  1. ArticleHow defocusing magnets help a beam stay in a ring
Something broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy