A degenerate pair
Diagonalize the coupled pair before computing line positions. The two transverse orbital states remain unshifted to first order.
QUANTUM EVIDENCE / ELECTRIC FIELDS
Send excited hydrogen through an electric field. Resolve its polarized ultraviolet spectrum, acquire photon counts and infer the field from the recorded splitting.
Schematic geometry · enlarged gaps and components · colors and moving markers do not represent visible light or measured trajectories. Drag to orbit.
EXPOSURE / TWO INDEPENDENT COUNTS
Each coordinate has a signal exposure and a separate reference: whole-line monitor. Exposure time controls Poisson noise; scan playback is accelerated.
Ready. Predict, then acquire.
Recorded points
Outer-line separation · source
Single outer shift per field
ACQUIRED SPECTRUM / COUNTS PER SECOND
·
Teal: source expectation. Gold: acquired rates with fitted Poisson standard deviations, once a fit exists. Purple dashes: inference from records. Gray dots: saved run. Background is included.
Click or drag to move the probe; its slider supports keyboard input. The vertical scale follows the data.
INFERENCE / JOINT POISSON LIKELIHOOD
Inferred field
Inferred source rate
Deviance per degree
Unsplit alternative
Gold: signal residuals. Blue: reference residuals. Known response, splitting/width controls and background; unknown source rate and spectral parameter. At least sixteen distinct probe positions are required. Descriptive residuals and deviance do not establish identifiability, confidence intervals or discovery significance.
Save a full or partial run with settings and seed in this page session.
| # | Signal | Whole-line monitor |
|---|
Latest six points shown. CSV includes all raw counts, exposures, settings, units and seed. Changing the probe never changes acquired records.
The electric field points vertically; excited atoms cross the plate gap perpendicular to the photon collection axis. The analyzer angle is measured from the field. The ideal ultraviolet selector counts a 2.5 GHz channel after Gaussian broadening.
The four spinless excited states have equal, externally maintained populations. Observation perpendicular to the field gives two parallel-polarized shifted components and a perpendicular central component. An ideal analyzer preserves constant total flux as it changes their weights. At perpendicular polarization the records contain no field information.
This first-order, fixed-nucleus Coulomb calculation deliberately neglects fine structure, Lamb shifts, quadratic corrections, Doppler kinetics and ionization. At low fields it is not the spectrum of real hydrogen; even at high fields it is only a qualitative teaching limit. The reference frequency is the gross Lyman line; the plotted axis is detuning, not a high-accuracy absolute wavelength.
Independent Poisson exposures, fixed calibrated background and stable source. No drift, dead time or calibration uncertainty. The source follows the displayed model; successful recovery validates the simulator, not the historical discovery.
Physics tutorial
BackgroundSend excited hydrogen through an electric field. Resolve its polarized ultraviolet spectrum, acquire photon counts and infer the field from the recorded splitting.
Why it mattersA line becomes evidence only through a measurement and a stated response model.
Start with the essentials
Diagonalize the coupled pair before computing line positions. The two transverse orbital states remain unshifted to first order.
Equal upper-state populations and observation perpendicular to the field give these normalized weights after an ideal analyzer.
The instrument full width is converted to Gaussian standard deviation. Channel integration preserves probability.
Background is independently known. Source rate and the spectral parameter are jointly inferred; reference uncertainty is included. Counts are never Gaussian-rounded.
Typical misconceptionA good fit independently confirms the law used by the simulator.
Better mental modelThe source response is supplied. Parameter recovery validates this synthetic measurement loop. Descriptive deviance and residuals are not confidence intervals, significance tests or external scientific certification.
Scan the default spectrum. Compare the inferred field with its source setting, then save the run.
What to observe: The outer components move in opposite directions. The estimator reads the counts and known response, not the source field.Choose parallel polarization, scan, then choose the no-field-information preset and scan again.
What to observe: The shifted components disappear under perpendicular polarization. An unchanged central line cannot identify the field.Broaden the instrument at a small field. Compare the recorded spectrum with the saved run and the unsplit alternative.
What to observe: Blending changes how well the inverse problem is constrained. A small residual alone is not proof of a unique parameter.