Lamb Shift Microwave Bench

Drive a beam of metastable hydrogen toward a short-lived state. Record the loss of surviving atoms, compare microwave-off counts and locate an effective Lamb resonance.

Interactive modelLamb Shift Microwave Bench

Schematic geometry · enlarged gaps and components · colors and moving markers do not represent visible light or measured trajectories. Drag to orbit.

EXPOSURE / TWO INDEPENDENT COUNTS

Give the spectrum a record.

Each coordinate has a signal exposure and a separate reference: microwaves off. Exposure time controls Poisson noise; scan playback is accelerated.

Ready. Predict, then acquire.

Recorded points

00

Metastable survival · model

00

Effective energy gap · source

00

ACQUIRED SPECTRUM / COUNTS PER SECOND

Which structure survives measurement?

ν/MHz\nu/\mathrm{MHz} · Ni/τi  (s−1)N_i/\tau_i\;(\mathrm{s^{-1}})

Teal: source expectation. Gold: acquired rates with fitted Poisson standard deviations, once a fit exists. Purple dashes: inference from records. Gray dots: saved run. Background is included.

Click or drag to move the probe; its slider supports keyboard input. The vertical scale follows the data.

INFERENCE / JOINT POISSON LIKELIHOOD

Estimate from both exposures.

Inferred center

—\text{—}

Inferred source rate

—\text{—}

Deviance per degree

—\text{—}

Flat alternative

—\text{—}

ri=(Ni−μ^i)/μ^ir_i=(N_i-\widehat\mu_i)/\sqrt{\widehat\mu_i}

Gold: signal residuals. Blue: reference residuals. Known response, splitting/width controls and background; unknown source rate and spectral parameter. At least sixteen distinct probe positions are required. Descriptive residuals and deviance do not establish identifiability, confidence intervals or discovery significance.

Keep the original counts.

Save a full or partial run with settings and seed in this page session.

#ν/MHz\nu/\mathrm{MHz}SignalMicrowaves offτ/s\tau/\mathrm{s}

Latest six points shown. CSV includes all raw counts, exposures, settings, units and seed. Changing the probe never changes acquired records.

Scientific scope, geometry & primary sources

Prepared metastable hydrogen travels from the source through a microwave interaction gap without static fields to a metal collector. Only surviving metastable atoms contribute to the signal. Atoms transferred to the short-lived state radiatively decay before collection; the collector is not a photon detector.

An effective isolated transition uses a rounded 1057.8 MHz reference center and a 100 MHz natural full width. The source-center control also represents a hypothetical frequency offset. Weak-drive adiabatic elimination gives exponential loss during the selected interaction time. The largest drive is four percent of the decay width; the shortest interaction is much longer than the short-lived-state lifetime.

Hyperfine and Zeeman structure, velocity distributions, coherent transients, stray-field quenching and collector calibration are omitted. The reference exposure switches microwaves off. This is not a reconstruction of the historical magnetic-field experiment or a calculation of radiative corrections. Fitting the supplied resonance cannot independently verify QED.

Independent Poisson exposures, fixed calibrated background and stable source. No drift, dead time or calibration uncertainty. The source follows the displayed model; successful recovery validates the simulator, not the historical discovery.

Physics tutorial

Lamb Shift Microwave Bench

BackgroundDrive a beam of metastable hydrogen toward a short-lived state. Record the loss of surviving atoms, compare microwave-off counts and locate an effective Lamb resonance.

Why it mattersA line becomes evidence only through a measurement and a stated response model.

Start with the essentials

Focus question
Tune the microwaves. Count who survives.
One-sentence intuition
Keep the signal and reference counts. Fit their joint Poisson likelihood while estimating the source rate from the same records.

Core mathematical model

Rapid decay, slow depletion

R(ν)=Ω2ΓΓ2+4[2π(ν−ν0)]2,Γ=2π (100 MHz)R(\nu)=\frac{\Omega^2\Gamma}{\Gamma^2+4[2\pi(\nu-\nu_0)]^2},\qquad \Gamma=2\pi\,(100\,\mathrm{MHz})

Rabi frequency and decay rate in this equation are angular quantities. The displayed frequency controls are ordinary frequencies.

Survivors are the signal

g(ν)=e−R(ν)t,ΔE=hν0g(\nu)=e^{-R(\nu)t},\qquad \Delta E=h\nu_0

Weak-drive elimination assumes a rapidly decaying destination and an interaction long compared with its lifetime. The metal collector counts metastable survivors.

Two independent exposures

Ni∼Poisson⁡ ⁣[τi(Sgi+b)],Mi∼Poisson⁡ ⁣[τi(S+b)]N_i\sim\operatorname{Poisson}\!\left[\tau_i(Sg_i+b)\right],\qquad M_i\sim\operatorname{Poisson}\!\left[\tau_i(S+b)\right]

Background is independently known. Source rate and the spectral parameter are jointly inferred; reference uncertainty is included. Counts are never Gaussian-rounded.

Common difficulties

Recovery is not discovery

Typical misconceptionA good fit independently confirms the law used by the simulator.

Better mental modelThe source response is supplied. Parameter recovery validates this synthetic measurement loop. Descriptive deviance and residuals are not confidence intervals, significance tests or external scientific certification.

Run the experiment

  1. 01

    Find a dip

    Scan the microwave frequency and compare each signal exposure with its separate microwave-off exposure.

    What to observe: A loss of collected metastable atoms marks the effective resonance. The instrument measures survival rather than direct microwave absorption.
  2. 02

    Change the interaction

    Save the default run. Extend the interaction time, scan again, and inspect the depth and wings.

    What to observe: Exponential depletion changes the spectral shape. The inverse problem uses that response, rather than fitting an arbitrary Lorentzian dip.
  3. 03

    Turn the microwaves off

    Use the zero-drive preset, scan, then restore the saved records and export the CSV.

    What to observe: Without coupling there is no resonance information. The estimated center is withheld even if random counts form an accidental dip.