Single-scattered amplitude
The assumed scattering amplitude has a forward lobe; direct and scattered paths differ by the neighbour distance times the angular path factor.
E64 · Structural photoemission
Acquire angular diffraction scans or standing-wave phase scans, then fit stored core-level counts and inspect the limits of structural inference.
Physics tutorial
BackgroundAcquire angular diffraction scans or standing-wave phase scans, then fit stored core-level counts and inspect the limits of structural inference.
Why it mattersWhich part of atomic structure can a count scan actually determine?
Start with the essentials
The assumed scattering amplitude has a forward lobe; direct and scattered paths differ by the neighbour distance times the angular path factor.
The density is a surface-truncated Gaussian. The effective escape length includes the takeoff-angle cosine. Coherent position need not equal mean depth.
Fit the constant, cosine and sine coefficients from stored counts with calibrated reflectivity. The amplitude is an unknown nuisance parameter.
Equivalent phase positions are separated by one period. Unknown layer abundance absorbs attenuation changes; one scan cannot select an absolute-depth branch.
Typical misconceptionA low residual establishes a unique atomistic structure.
Better mental modelSynthetic teaching models: one surface emitter and one scatterer with an assumed real scattering amplitude; or an ideal independently controlled standing-wave phase at fixed reflectivity. No element-specific phase shifts, multiple scattering, realistic Bragg rocking curve or nondipole correction. The layer signal is escape-weighted. Coherent position is periodic and is not a unique absolute depth. Apparatus, atomic spacing and layer thickness use different schematic magnifications.
Typical misconceptionThe residual map is a confidence interval or experimental resolution.
Better mental modelThe unweighted least-squares map is descriptive. Angular acceptance is independently calibrated; energy-dependent scales are fitted. The standing-wave fit leaves noisy fractions above unity visible and rejects insufficient rank or grossly unphysical fits. All counts are synthetic; no uncertainty or external certification is claimed.
Acquire an angular scan and move the selected point through the recorded angles.
What to observe: The collector follows the signed outward-normal angle. Direct and singly scattered waves interfere.Compare full coverage with the narrow and low-count examples.
What to observe: The search grid displays relative residual over distance and tilt. A sharp minimum is conditional on the assumed one-neighbour model.Acquire and fit a phase scan, then compare broad disorder and no reflection.
What to observe: Coherent modulation weakens when depths span multiple phases; zero reflection provides no phase information.Compare the completed phase scan with the one-period-deeper example.
What to observe: Phase repeats while absolute counts attenuate. Unknown abundance prevents a unique absolute depth; the two examples use separate synthetic specimens.