Frequencies of the static trap
The electric quadrupole field holds the electron along the trap axis, and the static magnetic field keeps its radial motion stable.
ONE ELECTRON / CONTINUOUS STERN–GERLACH
How can the spin of a single trapped electron be read from the frequency of its motion? A weak magnetic bottle makes the trap's restoring force slightly stronger or weaker depending on the spin direction, so the electron's axial oscillation has one of two nearby frequencies. A spin flip shows up as a jump between them. Counting flips during a microwave scan finds the spin resonance; comparing it with the measured cyclotron frequency gives the size of the electron's magnetic moment.
Calibrate the two axial frequencies that go with the two spin states. Then scan a microwave resonance, reading the axial frequency before and after each drive, and combine the measured trap frequencies to find the size of the electron's magnetic moment.
Static confinement; the field axis is vertical. The electron orbit is greatly enlarged and slowed independently of real frequency ratios. The pickup senses image current; no electron hits a detector.
Synthetic records, all observations kept
Ready to collect simulated data.
Sixty-four calibration records precede an interleaved 41-frequency scan. Every trial retains its measured before / after axial offset and the three measured trap frequencies. State preparation is ideal; acquisition is accelerated. The three trap-frequency channels are separate bottle-off calibrations. The fixed microwave reference is recorded in CSV.
Raw observations
First 240 drive trials, excluding calibration. Green: before; brown: after. Gray dashes show saved after-readings, clipped to the current plot range. Full records remain in CSV. The inspection slider selects one retained pair.
Inference using stated calibrations
Inferred moment magnitude
Fitted spin resonance offset
Reconstructed cyclotron frequency
Calibrated axial separation
Calibrated frequency noise
Inspected before / after offset
Classified trials with a binomial fit
A calibrated difference threshold classifies each frequency pair. A binomial likelihood fits center, width and drive strength. Error bars are a count scale, not a confidence interval. The source moment never enters the fit.
Check the records
Residuals outside five count scales appear as red edge dots. This tests the chosen phenomenological response, not a fundamental magnetic law.
Drive offsets are in megahertz; before / after axial offsets are in hertz.
| Index | Phase | Drive | Before | After |
|---|
The trap is an ideal static quadrupole Penning trap. The electron stays in its orbital ground state, and the weak magnetic bottle is treated to first order. The frequency noise is synthetic and white, state preparation is ideal, and the resonance follows a phenomenological incoherent model. Cavity effects, relativistic corrections, thermal cyclotron excitation, drift, quantum measurement backaction and the systematic corrections of precision work are left out. The orbit is drawn enlarged and the animation is schematic. The Lab does not reproduce a precision g-factor result.
The electric quadrupole field holds the electron along the trap axis, and the static magnetic field keeps its radial motion stable.
The magnetic bottle adds a restoring force that depends on the spin direction, so the two spin states have different axial frequencies. The orbital magnetic moment stays fixed.
The measured trap frequencies and the center of the fitted microwave resonance give the size of the moment. The electron's moment points opposite to its spin.
Positive magnetic moment points upward and lowers the axial frequency in a positive bottle. The displayed prepared high-frequency state has negative moment; electron spin points oppositely. The constant orbital contribution is absorbed in the baseline. The microwave field is transverse to the static field. Frequency readout is an ideal calibrated image-current estimator, not a synthesized electrical waveform.
The illustrative source uses drive strength 1.5 and a width of two megahertz plus 0.02 megahertz per unit bottle coefficient. This phenomenological broadening demonstrates a readout / linewidth tradeoff; it does not calculate the physical bottle lineshape. A symmetric readout error estimated from calibration corrects the binomial likelihood. Weak calibration or a fit boundary withholds the magnetic moment.
Dehmelt · Nobel lectureFan et al. · Electron magnetic momentCERN · Trap and image-current readout
Molecular-Beam Proton Magnetic MomentQuantum evidence collection
Physics tutorial
BackgroundCalibrate the two axial frequencies that go with the two spin states. Then scan a microwave resonance, reading the axial frequency before and after each drive, and combine the measured trap frequencies to find the size of the electron's magnetic moment.
Why it mattersThe constant is inferred from a calibrated instrument response and the observations you keep.
Start with the essentials
The electric quadrupole field holds the electron along the trap axis, and the static magnetic field keeps its radial motion stable.
The magnetic bottle adds a restoring force that depends on the spin direction, so the two spin states have different axial frequencies. The orbital magnetic moment stays fixed.
The measured trap frequencies and the center of the fitted microwave resonance give the size of the moment. The electron's moment points opposite to its spin.
Typical misconceptionGetting a source parameter back out of the data independently confirms the law.
Better mental modelThe synthetic data test a measurement and inference procedure. They are not historical observations, they give no confidence interval for the parameter, and they are not external scientific certification.
Choose the Resolved jumps preset and acquire. Look at each pair of axial-frequency offsets.
What to observe: The calibration prepares the moment in each of its two directions. It never reads the hidden spin state of a scan trial.Move the Inspect retained trial slider and compare each inferred spin flip with its pair of frequency readings.
What to observe: Each trial is classed as a flip or no flip, and the resonance is fitted to those classes. The source magnetic moment never enters the fit.Choose the No readout coupling preset and acquire again.
What to observe: The static trap still holds the electron, but the axial frequency no longer tells the two spin states apart.Quantum evidence · Reading path
Articles on this path that use this experiment, followed by the other experiments they suggest.