Static confinement
The electric quadrupole confines axially; the static magnetic field stabilizes radial motion.
ONE ELECTRON / CONTINUOUS STERN–GERLACH
Calibrate two axial-frequency levels, retain before-and-after frequency pairs, scan a microwave resonance and combine measured trap frequencies to infer the electron magnetic-moment magnitude.
Static confinement; the field axis is vertical. The electron orbit is greatly enlarged and slowed independently of real frequency ratios. The pickup senses image current; no electron hits a detector.
SYNTHETIC RECORDS / RETAINED OBSERVATIONS
Ready to acquire synthetic records.
Sixty-four calibration records precede an interleaved 41-frequency scan. Every trial retains its measured before / after axial offset and the three measured trap frequencies. State preparation is ideal; acquisition is accelerated. The three trap-frequency channels are separate bottle-off calibrations. The fixed microwave reference is recorded in CSV.
RAW OBSERVATIONS
First 240 drive trials, excluding calibration. Green: before; brown: after. Gray dashes show saved after-readings, clipped to the current plot range. Full records remain in CSV. The inspection slider selects one retained pair.
INFERENCE / DECLARED CALIBRATIONS
Inferred moment magnitude
Fitted spin resonance offset
Reconstructed cyclotron frequency
Calibrated axial separation
Calibrated frequency noise
Inspected before / after offset
CLASSIFIED TRIALS / BINOMIAL FIT
A calibrated difference threshold classifies each frequency pair. A binomial likelihood fits center, width and drive strength. Error bars are a count scale, not a confidence interval. The source moment never enters the fit.
CHECK THE RECORD
Residuals outside five count scales appear as red edge dots. This tests the chosen phenomenological response, not a fundamental magnetic law.
Drive offsets are in megahertz; before / after axial offsets are in hertz.
| Index | Phase | Drive | Before | After |
|---|
Ideal static quadrupole Penning trap; fixed ground orbital state; first-order weak magnetic bottle. Synthetic white frequency noise, ideal state preparation and a phenomenological incoherent resonance. No cavity, relativistic, thermal cyclotron, drift, quantum measurement backaction or precision systematic corrections. Enlarged orbit and animation are schematic; this is not a recreation of a precision g-factor result.
The electric quadrupole confines axially; the static magnetic field stabilizes radial motion.
A spin-dependent magnetic restoring force shifts the axial frequency. The orbital magnetic moment is fixed.
Measured trap frequencies and the fitted microwave center determine the moment magnitude; the electron moment is antiparallel to spin.
Positive magnetic moment points upward and lowers the axial frequency in a positive bottle. The displayed prepared high-frequency state has negative moment; electron spin points oppositely. The constant orbital contribution is absorbed in the baseline. The microwave field is transverse to the static field. Frequency readout is an ideal calibrated image-current estimator, not a synthesized electrical waveform.
The illustrative source uses drive strength 1.5 and a width of two megahertz plus 0.02 megahertz per unit bottle coefficient. This phenomenological broadening demonstrates a readout / linewidth tradeoff; it does not calculate the physical bottle lineshape. A symmetric readout error estimated from calibration corrects the binomial likelihood. Weak calibration or a fit boundary withholds the magnetic moment.
Dehmelt · Nobel lectureFan et al. · Electron magnetic momentCERN · Trap and image-current readout
Molecular-Beam Proton Magnetic MomentQuantum evidence collection
Physics tutorial
BackgroundCalibrate two axial-frequency levels, retain before-and-after frequency pairs, scan a microwave resonance and combine measured trap frequencies to infer the electron magnetic-moment magnitude.
Why it mattersA constant is inferred through a calibrated response and retained observations.
Start with the essentials
The electric quadrupole confines axially; the static magnetic field stabilizes radial motion.
A spin-dependent magnetic restoring force shifts the axial frequency. The orbital magnetic moment is fixed.
Measured trap frequencies and the fitted microwave center determine the moment magnitude; the electron moment is antiparallel to spin.
Typical misconceptionRecovering a source parameter independently confirms the law.
Better mental modelThese synthetic records test a measurement and inference workflow. They are not historical observations, a parameter confidence interval, or external scientific certification.
Acquire the resolved-jump preset. Inspect paired axial offsets.
What to observe: Calibration uses both prepared magnetic-moment directions, without reading hidden trial spin labels.Compare inferred transitions with the retained frequency pairs. Move the inspection slider.
What to observe: The resonance is fitted to classified records; source magnetic moment is excluded from the estimator.Select no readout coupling and acquire again.
What to observe: The electron remains statically confined, but axial frequency no longer distinguishes spin.