Molecular magnetic moment
In a strong field, ortho hydrogen splits into nine components with equal populations. In this model, para molecules with rotation zero have no permanent moment.
Hydrogen molecules / Magnetic deflection
How can a beam of hydrogen molecules measure the proton's magnetic moment when the molecules' rotation is magnetic too? By allowing for the known rotational part. A field gradient pushes each molecule sideways according to its magnetic moment. Para hydrogen has none and flies straight; ortho hydrogen splits into components mixing the two protons' moment with the rotational one. Slow molecules bend more, so every speed is timed. With that part and the ortho share known, the spread of hits gives the proton moment.
Send hydrogen molecules through the magnet, alternating between field off and field on, and record each molecule's upstream flight time and where it lands on the detector. Then infer an effective proton moment from the measured velocity distribution and a stated rotational contribution.
Beam travels left to right; positive magnetic moment deflects upward. Transverse displacement is enlarged 56 times relative to the longitudinal scale. Colored paths are source expectations at the mean speed, not recorded trajectories.
Synthetic records, all observations kept
Ready to collect simulated data.
Upstream timing triggers alternate field-off / field-on. Detector misses retain a trigger and flight time with an empty position. The known gradient, ortho fraction and rotational moment are calibration inputs; source moment, mean speed and beam width are excluded from inference.
Raw observations
Green: field off. Brown: field on. The detector bins have equal width, and empty bins show zero. Gray dashes show saved field-on counts. Missed events stay in the CSV and in the censored likelihood. The plot shows these counts, not an ideal detector image.
Inference using stated calibrations
Inferred effective proton moment
Fitted field-off center and width
Recorded detector acceptance
Second-moment cross-check · full acceptance only
Fixed rotational contribution
Inspected flight time and position
Kept events with a profile likelihood
The likelihood mixes nine ortho magnetic components and a para reference, using each flight time. Center and width are fixed by field-off records; the profile omits calibration uncertainty and is not a confidence interval. Values above forty are clipped visibly at the top.
Check the records
First 600 registered events; all triggers are retained in the export. Slower molecules deflect more. No source mean speed is used in the estimator.
Flight times are in microseconds; detector positions are in millimetres. Missed positions remain blank in CSV.
| Index | Field on | Flight | Position | Detected |
|---|
The source prepares hydrogen in its vibrational ground state: para hydrogen with rotation zero and ortho hydrogen with rotation one. The field is strong enough that the nuclear and rotational projections are uncoupled. The ortho fraction and the rotational moment are known, the force comes from a constant gradient in the paraxial limit, and the reference beam is Gaussian. Molecular shielding, diamagnetism, higher rotational states, spin-rotation coupling, collisions, fringe fields and calibration uncertainty are left out. The events are synthetic; they are neither Stern’s historical data nor a precision measurement of the free proton.
In a strong field, ortho hydrogen splits into nine components with equal populations. In this model, para molecules with rotation zero have no permanent moment.
The magnet is one tenth of a metre long. The molecules then drift half a metre to a detector that faces the beam.
Two timing gates upstream measure the speed of every triggered molecule, including those that miss the detector. The source speeds follow an illustrative lognormal distribution, not the Maxwell law of an effusive beam.
The two timing gates are upstream of the magnet and ten centimetres apart. The detector is half a metre beyond the ten-centimetre magnet and accepts positions within four millimetres of the axis. All event flight times are ideal; timing uncertainty is omitted. Known prepared ortho fraction is not inferred from the profile. The reported positive magnitude cannot determine the sign of the proton moment from a symmetric unpolarized beam.
A separate second-moment cross-check is shown only when every detector event is accepted. Finite acceptance enters the likelihood through Gaussian tail probability for each upstream trigger. No diamagnetic or shielding correction is applied; the inferred parameter is effective within this molecular model.
Stern · Molecular raysBarnes, Bray & Ramsey · Rotational momentNIST · CODATA
Single-Electron Penning Trap & Spin ReadoutQuantum evidence collection
Physics tutorial
BackgroundSend hydrogen molecules through the magnet, alternating between field off and field on, and record each molecule's upstream flight time and where it lands on the detector. Then infer an effective proton moment from the measured velocity distribution and a stated rotational contribution.
Why it mattersThe constant is inferred from a calibrated instrument response and the observations you keep.
Start with the essentials
In a strong field, ortho hydrogen splits into nine components with equal populations. In this model, para molecules with rotation zero have no permanent moment.
The magnet is one tenth of a metre long. The molecules then drift half a metre to a detector that faces the beam.
Two timing gates upstream measure the speed of every triggered molecule, including those that miss the detector. The source speeds follow an illustrative lognormal distribution, not the Maxwell law of an effusive beam.
Typical misconceptionGetting a source parameter back out of the data independently confirms the law.
Better mental modelThe synthetic data test a measurement and inference procedure. They are not historical observations, they give no confidence interval for the parameter, and they are not external scientific certification.
Choose the Ortho / para mixture preset and acquire. Compare where the molecules land with the field off and with it on.
What to observe: The center and Gaussian width that both runs share are fitted from the field-off reference beam. The source settings are not used.Choose the Broad velocity spread preset and look at the flight-time scatter plot.
What to observe: The likelihood uses each molecule's measured speed. It also includes the rotational contribution and the molecules that miss the finite detector.Choose the Para only or No gradient preset and compare.
What to observe: Without a force, or without ortho molecules, even a narrow reference beam cannot pin down the proton moment.Quantum evidence · Reading path
Articles on this path that use this experiment, followed by the other experiments they suggest.