Within one conditional state
FR12 · A mirror watched by light
Continuous Optomechanical Measurement
Why does brighter light reveal a mirror’s motion and shake it more? More probe photons reduce phase shot noise, but their fluctuating pressure adds momentum noise. A filter learns from the detected light; feedback uses that estimate to damp the mirror. Lost photons still disturb it.
Turn up the probe and compare the detector record with the inferred motion. Use that same record to cool a vibrating mirror, then compare one conditional state with an ensemble of experiments.
State widths below refer to the end of the stored record.
Across repeated experiments
Conditional position uncertainty
Open-loop resonance optimum
The noisy light and the inferred motion
The amber curve averages ten stored detector samples per displayed point. The filter uses every original sample. Gray is the simulated phase-space sample, not measured motion.
Where the measurement noise comes from
Open-loop theoretical references. Vertical axis is logarithmic. The integral over both frequency signs, divided by two pi, gives variance; imprecision is the white detector floor.
Knowing more and moving less
Ellipses show one-standard-deviation covariance contours, both recentered to compare their widths. Dots sample the distribution of conditional means from the same Gaussian model. Feedback narrows that distribution.
What is stored and what is a reference
CSV keeps all detector samples, causal commands, conditional means and covariances, the seed, time step, parameters and version. Wigner simulator coordinates have separate columns. Replaying the detector samples alone reproduces the filter and commands. The spectrum is an analytic open-loop reference; the ensemble covariance is propagated for the same finite-time measurement channel and feedback law.
Aspelmeyer, Kippenberg and Marquardt · measurement and feedbackStudy quantum optomechanics from moving mirrors to single photons
Physics tutorial
Follow the mirror through a noisy record
BackgroundTurn up the probe and compare the detector record with the inferred motion. Use that same record to cool a vibrating mirror, then compare one conditional state with an ensemble of experiments.
Why it mattersMore light supplies more information and more random force. Their competition matters before a feedback controller can help.
Start with the essentials
- Focus question
- Can observing a mirror more precisely cool its actual motion?
- One-sentence intuition
- Conditioning narrows what one record leaves uncertain. Feedback changes the distribution across repeated experiments.
Core mathematical model
A calibrated detector record
Dimensionless position and momentum have vacuum variance one half. Normalized time is mechanical angular frequency times time. The Wiener increment has variance equal to the time increment.
The two added noises
These are symmetrized double-sided spectra per normalized angular frequency. Force noise must pass through the mechanical susceptibility before it becomes displacement noise. The reference spectrum always assumes feedback off.
Information and feedback play different roles
The ensemble covariance includes both the uncertainty within each conditional state and the spread of its centers. The next force uses the momentum estimated from earlier detector samples.
Common difficulties
A small conditional state need not mean a cold ensemble
Typical misconceptionThe inferred ellipse shrank, so the mirror must have lost energy.
Better mental modelDifferent records place narrow states at different centers. Feedback damps those estimated centers; conditioning alone does not remove the ensemble spread.
Run the experiment
- 01
Turn up the light
Compare Light barely watches, Resolve the motion and Light shakes the mirror.
What to observe: The white imprecision floor falls. The backaction peak grows, and the mirror’s simulated motion broadens. - 02
Cool using the same samples
Choose Cool from the record, save the run, and set feedback to zero. Restore the saved run and export its samples.
What to observe: Feedback reduces the amber ensemble ellipse. The cyan conditional ellipse describes the remaining uncertainty for one record. Exported forces can be rebuilt from exported detector samples. - 03
Lose some of the photons
Lower Detection efficiency at fixed Measurement strength and compare the two state widths.
What to observe: The detector learns less, but the mirror still receives the same backaction. Feedback then has less reliable information to act on.
Related experiments and articles
Quantum optomechanics · Reading path
From a moving mirror to quantum measurement
Articles on this path that use this experiment, followed by the other experiments they suggest.