Skip to main content
Sandbox Physics

CONTINUOUS NUCLEAR RESONANCE / LINE SHAPE

Continuous-wave NMR Spectrometer

Balance a radio-frequency bridge, step the drive frequency, and retain absorption and dispersion voltages. Estimate the resonance center and power-broadened line width from those records.

Interactive modelContinuous-wave NMR Spectrometer

Nominal vertical static field, transverse sample coil. Continuous RF and a matched reference arm feed a balanced bridge; the residual reaches a phase-referenced receiver. Ideal cancellation and flat calibrated gain, not a solved RF circuit. Cable motion is schematic. B0=0.35 T,fref≃14.902 MHzB_0=0.35\,\mathrm{T},\quad f_{\rm ref}\simeq14.902\,\mathrm{MHz}

CONTINUOUS DRIVE / SETTLED VOLTAGE EXPOSURES

Step the frequency. Keep both phases.

Set frequency and RF amplitudeReach exact steady stateAverage independent IQ voltages

121 independent settled exposures span the drive offset from minus 180 to plus 180 hertz. Each point uses the selected fixed RF amplitude. This is a stepped steady-state scan; the accelerated playback does not model rapid passage or finite dwell.

Ready. Predict, then acquire.

RAW VOLTAGES / SEPARATE SOURCE EXPECTATION

Absorption is even. Dispersion changes sign.

(f−fref)/Hz,I,Q  (μV)(f-f_{\rm ref})/\mathrm{Hz},\quad I,Q\;(\mathrm{\mu V})

Teal: absorptive in-phase voltage. Gold: dispersive quadrature voltage. Dots: observations. Thin lines: source expectations. Purple dashes: record-only fit. Gray: exact saved records. Constant receiver baselines are retained and fitted.

RESIDUALS / COMPUTED FROM RETAINED VOLTAGES

What the fit leaves behind.

(I−Ifit),  (Q−Qfit)(μV)(I-I_{\rm fit}),\;(Q-Q_{\rm fit})\quad(\mathrm{\mu V})

Only recorded coordinates appear. No residual is generated before a supported fit. A small residual shows consistency with this response family, not independent confirmation of the physical law.

INFERENCE / SOURCE PARAMETERS EXCLUDED

Inferred resonance offset

—\text{—}

Inferred full width at half height

—\text{—}

Inferred absorption peak above baseline

—\text{—}

Retained complex exposures

00

Voltage residual RMS

—\text{—}

Unknown channel amplitudes and baselines are profiled out. The line width includes drive saturation. A lifetime is not inferred from this width. Search bounds and weak-information thresholds are diagnostic heuristics, not confidence intervals.

Latest raw observations
Index(f−fref)/Hz(f-f_{\rm ref})/\mathrm{Hz}I/μVI/\mathrm{\mu V}Q/μVQ/\mathrm{\mu V}

SAVED COMPARISON / LIMITS & SOURCES

Single homogeneous, noninteracting resonance with exponential Bloch relaxation. No static field distribution, molecular shifts or coupling, heating, diffusion, radiation damping, finite settling, bridge imbalance, drive leakage, phase error or RF circuit loading. Receiver gain is assumed flat over the narrow carrier span. The bridge measures response voltage, not absorbed watts or individual nuclear outcomes.

Physics tutorial

Continuous-wave NMR Spectrometer

BackgroundBalance a radio-frequency bridge, step the drive frequency, and retain absorption and dispersion voltages. Estimate the resonance center and power-broadened line width from those records.

Why it mattersA constant is inferred through a calibrated response and retained observations.

Start with the essentials

Focus question
A resonance has two faces.
One-sentence intuition
Keep source assumptions separate from estimates made from records.

Core mathematical model

Steady absorption and dispersion

v=ΩT21+(ΔT2)2+Ω2T1T2u=ΔT2v\begin{aligned}v&=\frac{\Omega T_2}{1+(\Delta T_2)^2+\Omega^2T_1T_2}\\u&=\Delta T_2v\end{aligned}

Normalized rotating-frame components. Detuning is sample frequency minus drive frequency; the bridge phase maps absorption to the in-phase channel.

Power broadens the line

ΓFWHM=1+Ω2T1T2πT2\Gamma_{\rm FWHM}=\frac{\sqrt{1+\Omega^2T_1T_2}}{\pi T_2}

This is the full width at half height of baseline-subtracted absorption. An intrinsic time follows from inverse width only in the weak-drive homogeneous limit.

Fit what was recorded

I=bI+a1+x2Q=bQ+dx1+x2,x=c−fh\begin{aligned}I&=b_I+\frac{a}{1+x^2}\\Q&=b_Q+\frac{d x}{1+x^2},\quad x=\frac{c-f}{h}\end{aligned}

Both channel amplitudes and constant baselines are unknown nuisance parameters. Center and half-width are found jointly, without source lifetimes or drive entering the fit.

Common difficulties

A simulation supplies its law

Typical misconceptionRecovering a source parameter independently confirms the law.

Better mental modelThese synthetic records test a measurement and inference workflow. They are not historical observations, a parameter confidence interval, or external scientific certification.

Run the experiment

  1. 01

    Read both channels

    Scan the reference line; compare the absorption maximum and the baseline-subtracted dispersive sign change.

    What to observe: Both responses share one center and width. Dots are retained voltages; thin source curves are a separate reference.
  2. 02

    Broaden with drive

    Save the run, select the strong-drive preset and scan again.

    What to observe: The line broadens while the source transverse time is unchanged. The estimate reports the broadened width.
  3. 03

    Remove the signal

    Turn the RF drive off and acquire the same scan.

    What to observe: A baseline and noise do not locate a resonance; weak-information diagnostics withhold the line estimate.
FeedbackSomething broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy