How do atoms turn energy gaps into frequency measurements?
Find a photon frequency from an atomic energy gap. Use the phase accumulated between two pulses to explain the width of Ramsey fringes.
Before you start: Chapter 3 on relative phase and Chapter 5 on two-state measurement.
After this chapter you can: Predict a hydrogen line from its energy gap and relate the width of Ramsey fringes to the free evolution time.
An atom absorbs light efficiently at a frequency set by the energy gap and the transition it can make. Ramsey spectroscopy measures such a transition against a reference oscillator. Two pulses convert the phase gained between them into an excited-state population. The longer the interval, the more phase a given frequency difference accumulates.
6.1 The gap sets the line position
An atom prepared in a lower state can absorb a photon and reach a higher state. For initial and final energies Ei and Ef>Ei, the resonance frequency ν0 and associated vacuum wavelength λ0 obey
ΔE=Ef−Ei=hν0.
The speed of light then relates the resonant frequency to its vacuum wavelength.
λ0=ν0c.
Here h is Planck's constant and c is the speed of light in vacuum. Emission across the same gap gives a photon at the same frequency in this energy-level model. For hydrogen, the nonrelativistic Coulomb model gives
En=−n2RH,RH≃13.5983eV.
The value of RH accounts for the finite proton mass. The principal quantum number n determines the model energy. From n=1 to n=2 the gap is about 10.1987eV and the vacuum wavelength is about 121.568nm. From n=2 to n=3 they are about 1.8887eV and 656.470nm. NIST tabulates average wavelengths of about 121.567nm and 656.464nm for the corresponding Lyman and Balmer lines. The Coulomb model leaves out shifts and splittings from fine structure and other smaller effects.
The line strength also depends on how the probe couples the two states. For weak light polarized along z, the electric dipole amplitude contains the overlap ⟨f∣z∣i⟩. Its squared magnitude enters the transition probability. The states 1s and 2s are both even under inversion, while z changes sign. The integral cancels between opposite points in space. The 2p state with m=0 has odd parity, and its overlap with z times the 1s state is nonzero. Thus a resonant z-polarized probe can drive 1s→2p with m=0. The 1s→2s electric dipole channel vanishes at the same model gap. Other transition mechanisms are outside this selection rule.
6.2 Two pulses make accumulated phase visible
A resonant π/2 pulse prepares a superposition of the two levels. The oscillator serves as a phase reference while the atom evolves freely. Define δf as the signed frequency offset in the convention that it advances the atomic phase relative to the reference by 2πδfτ during a dark interval τ. A second π/2 pulse with phase ϕ relative to the first converts that relative phase into a population. With full coherence, matching phases make the pulses add to a full flip. A phase difference of π makes the second pulse undo the first.
For instantaneous ideal pulses and exponential loss of coherence with time constant T2, the excited-state probability is
Pe(ϕ)=21+Ccos(2πδfτ−ϕ),C=e−τ/T2.
The contrast C=Pmax−Pmin measures how far the probability swings. A measured point is the excited fraction from repeated preparations at one phase. The model probability is the expectation of that fraction. For a fixed phase near a fringe midpoint, the magnitude of the frequency slope is πτC. A longer wait moves the phase farther per unit frequency, while loss of coherence reduces the population change it produces.
Figure 6.1 Simulated Ramsey probabilities versus second-pulse phase for dark intervals of 1ms and 4ms. Both curves use a frequency offset of 0.25kHz and a coherence time of 8ms. The longer interval shifts the phase of the maximum and reduces the contrast. Acquired counts fluctuate around these curves.
6.3 A single fringe leaves a frequency ambiguity
At fixed ϕ, the pattern repeats whenever the offset changes by 1/τ. A phase scan can determine where the maximum lies in one full turn. Adding an integer multiple of 1/τ to the frequency offset leaves every point on that scan unchanged. An expected frequency range narrower than one fringe period can select a branch. Scans at suitably chosen additional dark intervals can also distinguish candidate branches.
At 0.25kHz, the phase advance is π/2 after 1ms and 2π after 4ms. The second scan places the maximum at the same phase as zero offset. Its spacing in a frequency scan is 0.25kHz; the shorter interval gives 1.00kHz. Meanwhile, the model contrast falls from 0.882 to 0.607. A narrower fringe can help resolve small offsets within a known branch. Counting fluctuations, phase shifts due to the apparatus, and long-term oscillator drift each limit what the inferred frequency can establish.
6.4 Read a line and a fringe in the Labs
Open Hydrogen Orbitals & Spectra. Choose Allowed: a bright line, use Scan the line, and save the sample. Switch to Same gap, forbidden transition and scan again. Compare the two gap and vacuum wavelength readouts, then compare the excited-state fractions near zero probe detuning. The allowed model peak is about 0.0347. The forbidden channel gives zero in this simulation. Check for both results in the count plot, where the saved scan supplies a comparison. The Lab uses a weak Gaussian spectral envelope and ideal final-state detection.
Open Ramsey Frequency Measurement. Use Sensitive slope and Acquire scan, then compare with Long dark time. Use the phase scan for the maximum and contrast, and the sampled frequency spectrum for an approximate fringe spacing. Under Estimate a frequency from the counts, the longer-interval estimate should lie near the zero branch even though Frequency difference remains at 0.25kHz. Compare the offset modulo the fringe spacing and allow for count fluctuations. This task uses the main workbench with instantaneous pulses and phase decay. The separate clock analysis uses its own data and models additional systematic shifts.
6.5 Exercises
For hydrogen, derive the n=1 to n=2 gap in terms of RH.
The vacuum wavelength at the gap in Exercise 1 is 121.568nm. Use c=2.99792458×108m/s to find the light frequency.
Why does changing the z-polarized target from 2p with m=0 to 2s extinguish the line in the model?
With δf=0.25kHz and τ=1ms, what phase gives the largest excited fraction?
For T2=8ms, find the maximum excited probability at τ=1ms.
What is the frequency spacing between adjacent maxima at τ=4ms? Give two offsets indistinguishable from zero in that scan.
If the initial dark interval doubles from 1ms to 2ms at fixed T2=8ms, by what factor does the local midpoint slope change?
A single setting has Pe=1/2. Estimate the standard deviation of the excited fraction from 300 independent shots. Will more shots at this setting resolve a whole-fringe ambiguity?
Exercise 1Show the answer
ΔE=RH(1−1/4)=3RH/4. The final state has the greater energy, so the atom absorbs energy.
Exercise 2Show the answer
ν0=c/λ0≃2.466×1015Hz.
Exercise 3Show the answer
Both targets have n=2 and the same gap. The 2s dipole integrand is odd under inversion, so the spatial integral vanishes. The 2p integrand is even and has a nonzero integral for the specified polarization.
Exercise 4Show the answer
The phase advance is 2πδfτ=π/2. Set ϕ=π/2 modulo a full turn.
Exercise 5Show the answer
Pmax=(1+e−1/8)/2≃0.941. It occurs when the second pulse matches the accumulated phase.
Exercise 6Show the answer
1/τ=0.25kHz. Both +0.25kHz and −0.25kHz give the same phase modulo a full turn.
Exercise 7Show the answer
The slope ratio is 2e−(2−1)/8≃1.76. The ratio combines the extra phase accumulation with the loss of coherence.
Exercise 8Show the answer
The binomial standard deviation is Pe(1−Pe)/300≃0.029. More shots reduce this sampling noise. The candidate offsets separated by a whole fringe still yield identical probabilities.
Test it in the Lab
Change one setting at a time, then compare what you see with the tables and answers in this chapter.