After this chapter you can: Calculate a Bell correlation from four setting pairs and explain how dephasing affects the result.
A pair can give a random result at either detector while its joint outcomes depend strongly on both detector settings. A Bell test combines correlations at four settings to ask whether a local response model could account for them. An entangled state can exceed that model's limit. Which correlations survive depends on how the pair interacts with its surroundings.
Chapter 5 calculated probabilities in different measurement bases. Volume 5, Chapter 2, separated joint and conditional probabilities. Here we use both ideas for a pair of polarization measurements.
7.1 Local probabilities hide some of the information in a pair
Use horizontal and vertical polarization as the basis states ∣H⟩ and ∣V⟩. For a pair, write ∣HH⟩ when both components are horizontal and similarly for the other combinations. A Bell pair can be prepared in the pure state
∣Φ+⟩=2∣HH⟩+∣VV⟩.
Measuring both photons in the horizontal and vertical basis gives two joint outcomes, horizontal–horizontal and vertical–vertical, with probability one half each. Either photon alone looks equally likely to be horizontal or vertical. A source that randomly sends one of those two product states has the same statistics in that basis.
Now rotate both detectors by 45∘. In the coherent pair, amplitudes for opposite outcomes cancel. The two outcomes still match every time. The random mixture gives four equally likely outcomes in this basis. A joint pure state that cannot factor into two individual states is entangled. Changing the measurement basis exposes the relative phase between its two terms. MIT 8.06, Entanglement, Density Matrices, and Decoherence.
7.2 Four correlations test the limit of a local response
Let the two detectors use settings i and j, each zero or one. Give each detector outcome a sign, +1 or −1. The correlation Eij is the mean product of the two signs at that setting pair. The CHSH combination is
S=E00+E01+E10−E11.
In a local response model, each trial can carry a common random variable. For a fixed value of that variable, write the two possible local responses as A0,A1 and B0,B1. Each is a sign and each detector's response depends only on its own setting. Independent local randomness can be averaged over as part of the response table. The expression for one deterministic table is
A0(B0+B1)+A1(B0−B1).
If the two B signs agree, the first parenthesis is twice a sign and the second is zero. If they disagree, the roles reverse. Every table gives either plus or minus two. If the setting choices are independent of the source, all four correlations average over the same distribution of tables, so ∣S∣≤2. Clauser, Horne, Shimony and Holt, 1969.
For the Bell state in Section 7.1, linear polarizers at angles a and b give agreement probability cos2(a−b). For example, the amplitude for both positive outcomes projects the two horizontal components and the two vertical components, then adds them. The negative–negative amplitude gives the same probability. The correlation is
E(a,b)=2cos2(a−b)−1=cos(2(a−b)).
Choose a0=0∘, a1=45∘, b0=22.5∘ and b1=−22.5∘. The first three correlations are +1/2, the last is −1/2, and the result is S=22.
Each detector still has equal probabilities for its two outcomes whichever setting the other detector uses. The Bell sum requires both parties' records. Hensen and colleagues tested a CHSH inequality with entangled electron spins at separated sites and reported S=2.42±0.20 in 245 trials. A two-photon detection signaled a successfully prepared spin pair, and fast random settings chose the readout bases. Hensen et al., 2015.
7.3 Pair counts give a correlation for each setting
Open Bell Correlations & CHSH, choose Entangled pair, leave the angles and efficiencies at their defaults, and select Acquire all four settings once. Each simulated trial has randomly chosen settings. For a setting with both detectors responding, count same-sign pairs as positive and opposite-sign pairs as negative. Subtract the two counts and divide by their sum. Repeat with Local response model and a fresh acquisition.
Entangled source
Local comparison
Model prediction
Mean product of the outcomes−1−0.500.510, 00, 11, 01, 1
Settings at the two detectors
Figure 7.1 The four analyzer setting pairs. The last correlation is subtracted in the CHSH sum, so a negative value in that group increases the sum.
Table 7.1 Correlations from two simulated acquisitions with seed 1969 and 3200 trials each. All trials have two outcomes at these settings. Each correlation uses its own setting group's trial count.
Source
E00
E01
E10
E11
CHSH sum
Entangled
+0.7143
+0.6951
+0.6830
−0.6769
2.7692
Local response
+0.4856
+0.4708
+0.5314
−0.4590
1.9467
The ideal local response in the Lab gives S=2. The finite local count estimate lies near two and its interval spans the bound. For the entangled run the Lab's fixed-sample 95% interval is about [2.318,3.220]. These intervals describe variation in the simulated counts under the chosen protocol. If you lower detector efficiency, the Lab records misses and can assign each miss a fixed positive result for an all-trial comparison. Dropping missed trials instead changes the population being compared and requires a fair-sampling assumption.
7.4 Phase loss can leave the level populations unchanged
A density matrix records both outcome weights and coherence. Its diagonal entries in a chosen basis are the probabilities in that basis. Its off-diagonal entries connect different basis components. For example, when the environment loses the phase between the horizontal–horizontal and vertical–vertical terms, their two populations can stay fixed while the coherence between them shrinks. The matching outcomes in the original basis can survive even while correlations in another basis weaken. MIT 8.06, Entanglement, Density Matrices, and Decoherence.
Open Decoherence Channels & Information Loss and choose Lose phase. This Lab models a single two-level system, starting with equal level populations and a definite relative phase. The model reduces transverse coherence by e−Γφt while keeping the population difference fixed. At the default end time 2.00ms, with rate Γφ=1.00ms−1, the model positive probability along x is about 0.568, and the probability along z remains 0.500. Select Count three bases. The seeded run gives 217, 199 and 200 positives in 400 trials per basis along x, y and z, respectively. The separate Relax to ground setting gives 373 positives along z in its seeded 400 trials. This comparison separates phase damping from a change in energy populations.
The joint-state description extends to many particles. For quantum statistics, combine the thermal weights from Volume 5, Chapter 6, with the exchange symmetry of identical particles and count the allowed occupation states. To study a solid, first specify the lattice and the interactions between its sites. A joint spin measurement can then show which neighbors align even when the mean spin of each site is zero.
7.5 Exercises
In state ∣Φ+⟩, both detectors measure horizontal or vertical. Find the joint probability of two horizontal outcomes and the probability for the left detector alone to report horizontal.
Compare the pair in Exercise 1 with an equal mixture of two product states, both horizontal or both vertical. What happens if both detectors rotate by 45∘?
Suppose a local response table has A0=+1, A1=−1, B0=−1 and B1=+1. Calculate its contribution to the CHSH sum.
A setting group has 90 same-sign and 30 opposite-sign pairs. Calculate its correlation.
Use the four ideal angle choices in Section 7.2. What happens to the CHSH sum if all the ideal correlations are multiplied by 0.60?
In four groups a finite simulated experiment estimates a CHSH sum slightly above two. What else must you look at before concluding the result exceeds the local limit?
In a qubit model, phase damping erases off-diagonal terms in the energy basis. What happens to the energy populations, and which measurement can reveal the change?
Can the left detector learn the right detector's setting from its own results alone for the ideal Bell pair? Explain using conditional measurement settings and the marginal distribution.
7.6 Answers and explanations
Exercise 1Show the answer
The both-horizontal outcome has probability 1/2. The left detector reports horizontal only in that outcome in this basis, so its own horizontal probability is also 1/2.
Exercise 2Show the answer
The coherent pair still gives matching outcomes after the equal rotations. In the mixture, either original product state gives independent half probabilities at each rotated detector. The mixture gives all four outcomes with equal probabilities.
Exercise 3Show the answer
The first parenthesis is zero and the second is −2. Multiplying the second by A1=−1 gives S=2 for that table.
Exercise 4Show the answer
The mean sign product is (90−30)/(90+30)=0.50. Same-sign products count positively and opposite-sign products count negatively.
Exercise 5Show the answer
The sum is linear in the correlations, so it becomes 0.60(22)≈1.697. It lies below two for these angles.
Exercise 6Show the answer
Check the uncertainty from finite trials and whether the trial selection, detector misses and setting choices support the comparison with the local bound. A point estimate alone can be above two because of count fluctuations.
Exercise 7Show the answer
The energy populations stay fixed because they are the diagonal terms in that basis. A measurement in a basis that combines the two energy components can respond to the loss of relative phase.
Exercise 8Show the answer
For either choice at the right, the left outcome probabilities are one half and one half. Summing the joint probabilities over the right result gives the same marginal. The right setting matters when the two records are compared.
Test it in the Lab
Change one setting at a time, then compare what you see with the tables and answers in this chapter.