After this chapter you can: Use amplitudes to predict a detection distribution and explain how the number of events affects a measured pattern.
A particle leaves one localized hit on the screen. The probabilities for those hits come from adding the amplitudes of the two paths and squaring the magnitude. After enough repetitions, the frequencies of hits in different parts of the screen reveal the bright and dark bands.
Volume 2, Chapters 5 and 6, introduced phase and superposition. Volume 4, Chapter 3, applied them to light through two slits. Here we use the same addition of amplitudes to predict individual detection probabilities. The counting examples use the probability from Volume 5, Chapter 2.
1.1 Add the amplitudes that can lead to the same detection
Prepare the same incident state for each trial. At position y, let ψL(y) and ψR(y) be the complex amplitudes from the left and right slits. Each contains a magnitude and a phase. When the alternatives remain coherent and the same detection outcome can come from either one, the screen amplitude is their sum. The Born rule gives the probability density from its squared magnitude.
The star denotes complex conjugate. The last term changes sign with the relative phase. Equal contributions cancel at a phase difference of half a cycle. When they arrive in phase, the combined magnitude is twice the magnitude of one contribution. The density at that point is four times the density from its individual term in the sum. These amplitudes refer to the same experiment. Closing one slit can also change how many incident particles reach the screen.
A probability density gives probability after integration over a region. With y in metres, a density normalized over the detection region has units of inverse metres. It integrates to one for the distribution of hits conditioned on a detection there. OpenStax, University Physics Volume 3, Section 7.1.
1.2 A path record changes which contributions can interfere
Suppose a marker ends in one distinguishable state if the left path contributes and a different distinguishable state if the right path contributes. A final outcome now includes both the screen hit and the marker state. When the marker states are perfectly distinguishable, the probabilities for the two joint outcomes add at a given screen position. The interference term vanishes from the screen distribution even if the marker is left unread.
An imperfect marker can leave some coherence. A finite spread of relative phases across trials can also reduce the average interference term. The Lab represents reduced contrast by multiplying the term by a number between zero and one. That number specifies the model's result of reduced coherence. The model has no separate marker detector.
A real double-slit experiment can count electron hits. Bach and colleagues used a movable mask to select either slit or both. With both slits open and the beam flux low, their Figure 3 shows localized events accumulating into a diffraction pattern. The simulated screen used here has its own envelope and geometry. Bach et al., Controlled double-slit electron diffraction.
1.3 The Lab draws each hit from a finite screen distribution
In Single-Particle Interference, the screen is a distance L from the slit plate. The vertical coordinate y increases upwards from the centre of the screen, and the accepted interval is −Y≤y≤Y. In the far field the diffraction of a rectangular slit of width a supplies the envelope. For two open slits with separation d, the screen density is
p(y)=λLasinc2(λLπay)[1+μcos(λL2πdy)].
Here λ is the de Broglie wavelength, μ is the coherence, and sincx=sinx/x with value one at zero. The expression assumes small angles and equal illumination of the two slits. One open slit gives the envelope alone. TU Delft, Scalar Diffraction Optics
The integral of p over the finite screen gives the chance of a hit there. A trial outside the screen is recorded as a miss. Among the detected particles, the probability of a position bin B is
pB=∫−YYp(y)dy∫Bp(y)dy.
Predict what happens to bright and dark bands when the path marks become distinguishable. Use Two coherent slits, then Paths distinguishable. Both presets have d=600nm, λ=60pm and L=1.5m, which set a nominal pitch of 150μm. The second preset takes the coherence to zero. The slit envelope remains and the modulation vanishes. Use Emit a batch to add trials, and compare the positions and the fraction missed.
1.4 More detections make the estimated distribution steadier
For independent trials with bin probability pB, let NB count hits within the bin out of N trials. Each hit contributes one to that count if it falls in the bin and zero otherwise. As in Volume 5, the mean fraction is pB and its standard deviation is
sd(NNB)=NpB(1−pB).
Four times as many hits give half the standard deviation in a fixed bin. A single bin can still fluctuate. The distribution is inferred from a set of repeated detections.
Figure 1.1 uses the actual Lab sampler in a separate reproducible run with fixed seed 270601. The small histogram is the first 128 hits of the same 4096-hit run. Both use 32 bins of equal width. Compare the fraction of hits in each bin with the probability obtained by integrating the model over that bin.
Figure 1.1 Simulated hit fractions from one seeded run, shown after 128 and 4096 detections. Dashed marks show the model probabilities for the same bins. The horizontal coordinate is dimensionless and covers the full visible screen.
For this run, half the sum of absolute differences between the bin fractions and the model probabilities drops from about 0.1118 to 0.0302. This is the total variation distance for the binned distributions. The larger sample resolves the low-probability gaps and high-probability bands more clearly. The quoted distances are specific to this run, seed and binning.
1.5 Exercises
At a screen point, the two complex amplitudes have equal magnitude and zero relative phase. How does the combined density compare with the contribution from one term? What if the phase difference is half a cycle?
Two amplitudes at a point have magnitudes in the ratio two to one and opposite phases. Can they cancel completely? Express the remaining density relative to the smaller amplitude's squared magnitude.
Why can a detector record a single hit when the calculation uses two amplitudes? What does the square of the sum predict?
The two paths leave perfectly distinguishable marks in a second detector. How do you combine their contributions when you retain only the particle positions?
Double the slit separation in the Lab model while holding wavelength and screen distance fixed. What happens to the nominal fringe spacing? Which part of the weight remains the same?
Suppose a bin has probability pB=0.20. Find the standard deviation of its measured fraction after N=400 independent detections. What is it after N=1600?
In the model, the coherence setting is zero. Is every coordinate on the screen equally likely? Which term controls the remaining variation?
Compare two histograms with the same number of detections, one with twice as many bins. Why can the narrower bins fluctuate more relative to their expected counts?
1.6 Answers and explanations
Exercise 1Show the answer
In phase, the amplitudes add to twice one amplitude, so the density is four times its separate term. Opposite phases make equal amplitudes sum to zero and give zero density.
Exercise 2Show the answer
Subtract the smaller amplitude from the larger one. The result has the magnitude of the smaller contribution, so the density is one times its squared magnitude. Complete cancellation would require equal magnitudes.
Exercise 3Show the answer
The detector gives one position per trial. The squared amplitude predicts the distribution of possible positions. Repeating the trial estimates that distribution from the observed frequencies.
Exercise 4Show the answer
Add the probabilities of the two distinguishable joint outcomes at each position. Each outcome has a different mark, so the screen distribution is the sum of the separate squared amplitudes.
Exercise 5Show the answer
The nominal spacing is λL/d, so it is halved. The envelope e−2.2u2 is unchanged because the slit separation enters only the phase factor.
Exercise 6Show the answer
With four hundred hits the standard deviation is 0.20(0.80)/400=0.020. With sixteen hundred it is 0.010 because the square root of the sample size doubles.
Exercise 7Show the answer
The cosine term is removed when μ=0. The envelope still makes positions near the center more likely than positions near the edges.
Exercise 8Show the answer
Smaller bins collect fewer expected hits in regions with a smoothly varying probability density. For a bin with small probability, the standard deviation of the count is close to the square root of the expected count. Dividing by the expected count makes the relative fluctuation larger when that count is small.
Test it in the Lab
Change one setting at a time, then compare what you see with the tables and answers in this chapter.