Skip to main content
Sandbox Physics

Quantum evidence / Light in a magnetic field

Zeeman Polarization Spectrometer

What does a spectral line look like in a magnetic field, viewed across and along the field? For atoms with zero total spin, it splits into three evenly spaced frequencies. Looking across the field, you see all three, and the middle one is polarized along the field. Looking along the field, the middle one vanishes and only the two outer, circularly polarized lines remain. Their spacing gives the field strength.

Look at a spin-zero atomic line from across the magnetic field and from along it. Rotate the polarization analyzer, count photons across the spectrum and work out the field from the components that get through.

Interactive modelZeeman Polarization Spectrometer

Schematic geometry with enlarged gaps and parts. The colors and moving markers do not show visible light or measured trajectories. Drag to orbit.

Exposure: signal and reference counted separately

Give the spectrum a record.

Each coordinate has a signal exposure and a separate reference: whole-line monitor. Exposure time controls Poisson noise; scan playback is accelerated.

Ready. Predict, then acquire.

Recorded points

00

Outer-line separation · source

00

Single-side shift per field

00

Measured spectrum in counts per second

Which structure survives measurement?

Δν/GHz\Delta\nu/\mathrm{GHz} · Ni/τi  (s−1)N_i/\tau_i\;(\mathrm{s^{-1}})

Teal: source expectation. Gold: acquired rates with fitted Poisson standard deviations, once a fit exists. Purple dashes: inference from records. Gray dots: saved run. Background is included.

Click or drag to move the probe; its slider supports keyboard input. The vertical scale follows the data.

Inference with a joint Poisson likelihood

Estimate from both exposures.

Inferred field magnitude

—\text{—}

Inferred source rate

—\text{—}

Deviance per degree

—\text{—}

Zero-field alternative

—\text{—}

ri=(Ni−μ^i)/μ^ir_i=(N_i-\widehat\mu_i)/\sqrt{\widehat\mu_i}

Gold: signal residuals. Blue: reference residuals. Known width, viewing angle, analyzer or stationary fraction, and background; unknown source rate and target field or energy. At least sixteen distinct probe positions are required. Descriptive residuals and deviance do not establish identifiability, confidence intervals or discovery significance.

Keep the original counts.

Save a full or partial run, with its settings and seed, for as long as this page stays open.

#Δν/GHz\Delta\nu/\mathrm{GHz}SignalWhole-line monitorτ/s\tau/\mathrm{s}

The latest six points are shown. The CSV has every raw count, exposure, setting and unit, plus the seed. Moving the probe never changes data already taken.

Scientific scope, geometry & primary sources

The spin-zero orbital model groups nine allowed singlet transitions into three frequencies. The upper magnetic sublevels have equal populations. A linear analyzer transmits the projection of each dipole radiation pattern; transverse parallel selection leaves only the field-insensitive central line. Along the field, the central component vanishes and rotating a linear analyzer leaves equal outer components. Circular handedness is not measured here.

Physical field is scene up. A lamp sits in the gap of two bored pole pieces; the optical arm collects either across the gap or through their axial aperture. Analyzer bars rotate in the same plane used by the response. The incoming ray reaches the upstream counter face. Gaps, source, apertures and supports are schematic and enlarged.

The scan uses an ideal calibrated Gaussian spectral selector followed by a photon counter, not a simulated Fabry–Pérot image. Each channel integrates 0.875 GHz. A separate whole-line reference bypasses the spectral selector after the same analyzer. The source rate means total post-analyzer collected flux; throughput and background are assumed calibrated.

The line is inspired by the approximately 643.8 nm cadmium singlet, but no absolute wavelength or isotope centroid is inferred. Linear orbital Zeeman shifts alone are retained. No spin, isotope structure, finite angular acceptance, lamp kinetics, self-absorption or magnetic calibration uncertainty is included. The normal triplet also has a classical oscillator explanation; observing this ideal pattern alone does not establish electron spin.

Independent Poisson exposures, fixed calibrated background and stable source. No drift, dead time or calibration uncertainty. The source follows the displayed model; successful recovery validates the simulator, not the historical discovery.

Physics tutorial

Zeeman Polarization Spectrometer

BackgroundLook at a spin-zero atomic line from across the magnetic field and from along it. Rotate the polarization analyzer, count photons across the spectrum and work out the field from the components that get through.

Why it mattersA spectral line becomes evidence only after you measure it and know how the instrument responds to it.

Start with the essentials

Focus question
What does a spectral line look like in a magnetic field, viewed across and along the field?
One-sentence intuition
Keep every signal and reference count. Fit them together with one Poisson likelihood, and estimate the source rate from those same counts.

Core mathematical model

Shifts of the normal Zeeman triplet

Δνq=q μBBh,q∈{−1,0,1}\Delta\nu_q=q\,\frac{\mu_{\mathrm B}B}{h},\qquad q\in\{-1,0,1\}

The two outer components move in opposite directions. The fit estimates the size of the field, not its sign, because a linear analyzer cannot tell the two circular polarizations apart.

Weights of the three components

w0=sin⁡2θcos⁡2α,w±=cos⁡2θcos⁡2α+sin⁡2α2,∑qwq=1w_0=\sin^2\theta\cos^2\alpha,\quad w_{\pm}=\frac{\cos^2\theta\cos^2\alpha+\sin^2\alpha}{2},\quad\sum_q w_q=1

The viewing angle is measured from the field. The analyzer angle is measured from the field's projection across the line of sight. When you look along the field, the analyzer angle is measured from a fixed transverse direction in the lab instead.

Two independent exposures

Ni∼Poisson⁡ ⁣[τi(Sgi+b)],Mi∼Poisson⁡ ⁣[τi(S+b)]N_i\sim\operatorname{Poisson}\!\left[\tau_i(Sg_i+b)\right],\qquad M_i\sim\operatorname{Poisson}\!\left[\tau_i(S+b)\right]

The background rate is known in advance. The source rate and the spectral parameter are fitted together, and the uncertainty of the reference counts is included. Counts are drawn as Poisson numbers, never rounded from a Gaussian.

Common difficulties

Recovering a parameter does not test the law

Typical misconceptionIf the fit is good, the law built into the simulator has been independently confirmed.

Better mental modelThe simulator is given the source response in advance. Recovering the parameter shows only that this simulated measurement and fit work correctly together. The deviance and residuals describe the fit; they are not confidence intervals, significance tests or outside scientific certification.

Run the experiment

  1. 01

    Resolve the triplet and count

    Choose Transverse triplet, scan, then save the run.

    What to observe: The three source peaks turn into noisy counts in each channel, and the fit returns a field strength.
  2. 02

    Remove the field information

    Choose Only the central line and scan again.

    What to observe: Photons are still counted, but the counts no longer depend on the field at all. No field estimate is reported.
  3. 03

    Look along the field

    Choose Look along the field, then rotate the analyzer.

    What to observe: The central line disappears, and the two outer lines keep equal weights.

Related experiments and articles

Quantum evidence · Reading path

Fields, spins and precision spectra

Articles on this path that use this experiment, followed by the other experiments they suggest.

  1. ArticleWhy a magnetic field splits a spectral line
  2. LabCoupled Spin SpectroscopySee how levels and line strengths change with the field
FeedbackSomething broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy