Charge-basis Hamiltonian
The charge hops only between neighboring integer numbers of Cooper pairs. The charge operator drives the transitions.
Q033 · Tuning a superconducting artificial atom
What do you give up when you make an artificial atom less sensitive to stray charge? Anharmonicity. Raising the ratio of Josephson energy to charging energy makes the levels exponentially less sensitive to stray charge, but the level spacings grow more alike. Once the qubit transition sits close in frequency to the next one up, it is hard to drive one without the other.
Change the ratio of Josephson energy to charging energy. See how the charge dispersion and the uneven level spacing change, and compare the transitions recorded from two starting states.
How can a weak microwave response tell us about a qubit state? The qubit changes the resonator response. A receiver compares two microwave quadratures with calibrated references, then a fixed classifier assigns the measured samples. Noise, decay and excessive probe power limit those assignments; command-labelled validation is not an independent certificate of the qubit state.
Trace the probe through the cold resonator, amplifier, IQ receiver and digitizer. Keep the measured samples and compare how the receiver separates its two training commands.
02 / What did the readout record?
· Blue: this sample. Orange: most recently saved other sample. Dashed: current model. Drag the cursor to tune.
At the selected frequency
Changed / preparations
95% Wilson interval for independent yes-or-no readouts at this frequency, shown only after sampling. Each interval holds point by point; together they do not form a simultaneous band, and they do not cover optional stopping.
Latest 60 recorded outcomes
Blue means changed; gray means unchanged. Every trial starts freshly prepared.
Recorded sample
03 / Where do the lines come from?
· · Model only. Drag horizontally; the matching slider also supports the keyboard.
Colored arrows: allowed transitions from the prepared level. Their thickness shows normalized strength. Gray ticks: other levels.
Model inspection · adds no counts
Prepared-state charge probabilities. Only the central seventeen charge states are plotted; all twenty-nine remain in the solver.
· Blue: first excited state. Orange: higher-level leakage. Always starts in the ground state; independent of the spectroscopy preparation.
Up to eight frozen samples. Restore to inspect; acquiring again starts a new run. CSV includes each bit, actual probe frequency and preparation. Reusing the seed reproduces draws, not independent evidence.
Energy is in the reference unit; probe frequency is ordinary frequency multiplied by Planck’s constant, not angular frequency. Curves and level arrows are model predictions. Recorded bits are simulated independent preparation–probe–readout trials.
Charge basis: 29 states centered on zero, checked against 33 states. The drive operator is charge. Lowest four energies are checked; higher levels are retained for transition-strength normalization. Charge dispersion is the absolute difference of the first gap at integer and half-integer offset charge. Larger junction energy reduces relative anharmonicity, not necessarily its absolute magnitude in charging-energy units.
Single fixed junction; no flux tuning law, quasiparticles, dielectric loss, cavity hybridization, multiphoton spectroscopy or lab-frame pulse dynamics. The chip and capacitive readout are a conceptual connection map, with junction size exaggerated. Ideal pure-state preparation and changed-state readout are assumed.
Koch et al. · Transmon Hamiltonian and design tradeoffs · Schreier et al. · Spectroscopy and charge dispersion
The readout uses an assumed incoherent Lorentzian response with a fixed one-percent false-change background and a twenty-percent contrast shared among the transitions. Width is the full width at half maximum. Strengths are normalized within the chosen preparation, so peak heights cannot compare absolute dipole moments across settings. All levels enter the normalization, including transitions outside the displayed band. This readout model does not solve coherent pulse dynamics and is not a fitted instrument calibration.
Simulated raw ADC acquisition
Independent positive and negative I/Q pilots determine an affine two-by-two receiver correction. Blank shots measure the total covariance; separate pilots check calibration. A linear classifier is trained only on known preparation commands, frozen, and then scored on held-out commands. Preparation errors and relaxation contribute to this score. It is not a certified quantum-state fidelity. Unknown shots carry no state labels or jump times. The Gaussian overlap is a reference for equal stationary Gaussian clouds, not a fitted fidelity.
Both formats keep calibration, training, held-out and unknown ADC samples, LO and clock readbacks, timing, external references and frozen classifier. Reconstruction is recomputed from these fields. Old records stay fixed when the live circuit or Reset changes. Valid raw data outside a supported power or calibration domain remain available for export, with state inference withheld.
Physics tutorial
BackgroundChange the ratio of Josephson energy to charging energy. See how the charge dispersion and the uneven level spacing change, and compare the transitions recorded from two starting states.
Why it mattersA spectrum tells you about both the Hamiltonian and the operator used to probe it.
Start with the essentials
The charge hops only between neighboring integer numbers of Cooper pairs. The charge operator drives the transitions.
This is only the limit for a large ratio; the plotted spectrum comes from diagonalization. Relative anharmonicity falls as the first gap grows.
Compare the first transition at two charge offsets. A small dispersion is not a measured coherence time.
Typical misconceptionEvery energy level must produce a visible peak.
Better mental modelThe prepared state, the probe operator, the line width, the frequency range and the finite number of counts all matter. Lines outside the plotted band still count in the strength normalization.
Typical misconceptionA narrow simulated line establishes a long experimental lifetime.
Better mental modelThe line width and the low-contrast Lorentzian response are inputs set in the model. The separate pulse test uses a rotating-wave model; it does not infer pulse dynamics or hardware noise.
Try the two charge-sensitive presets. Predict how much the first gap moves when the offset charge shifts.
What to observe: The dashed curve comes from the model, not from recorded data. Hide it while you predict.Scan, save the sample, change one preparation setting, then scan again.
What to observe: Every frequency gets its own fresh, independent trials. The orange points keep the most recently saved preparation.Prepare the first excited state, and tell the downward transition apart from the next upward one.
What to observe: A line's position is set by an energy difference, but the line shows up only if its matrix element is not zero.Read the instrument principle, sources and limits
Physics tutorial
BackgroundA qubit slightly shifts the resonance of a neighbouring cavity. A weak microwave probe leaves the cavity with an amplitude and phase that depend on the qubit state.
Why it mattersOne readout supplies a short noisy voltage trace. Assigning a class requires a calibrated receiver and a separate test of the decision rule.
Start with the essentials
The squared magnitude of cavity amplitude a is the mean photon number; s is the incident field. Ground and excited states use z=-1 and z=+1. Detuning Δ and pull χ are angular frequencies in radians per second. The total energy decay rate κ includes internal loss. A state jump preserves the existing cavity amplitude.
The mixer compares the signal with a local oscillator to produce in-phase I and quadrature Q. Both are RMS voltages at the post-amplifier reference plane, with Q multiplying negative sine. The analog-to-digital converter, or ADC, saves integer codes for each channel.
C is the calibrated blank-voltage covariance. S is a two-sided power spectral density in volts squared per hertz. The model has independent white-noise samples, so averaging N points divides covariance by N. The default 20 ns spacing and 32 samples give a 640 ns window with one-sided equivalent noise bandwidth 0.78125 MHz. Measured blanks include quantum and amplifier noise; vacuum is counted once.
Typical misconceptionThe default 68.75% is a certified state-readout fidelity.
Better mental modelIt is agreement with held-out preparation commands, with equal weight for each command's correct-assignment rate. Preparation errors and relaxation can change that agreement. The measured overlap stays in the result.
Typical misconceptionThe refrigerator-stage temperature determines chip temperature, lifetime and excited-state population.
Better mental modelStage temperature supplies an independent thermal boundary. Chip temperature, qubit lifetime and population each require their own measurement. Relaxation time is an independent input here.
Select Whole chain and follow the source through the cold line to the cavity, then inspect the receiver.
What to observe: Cold attenuators reduce probe power and upstream thermal noise. The output crosses an isolator and a cryogenic high-electron-mobility transistor amplifier, or HEMT, before reaching the mixer and ADC. The amplifier adds noise too.Compare State-dependent response, A faint probe and Rotate the receiver. Use Acquire and freeze after each change.
What to observe: A weaker probe makes the voltage clouds harder to separate. Receiver phase changes the direction of signal separation in the I/Q plane. The noisy clouds still overlap.Open the data explanation, check the reference, blank, training and held-out sample counts, and export the complete record.
What to observe: Known I/Q pilot signals calibrate channel scales, cross-talk and offsets. Blanks measure noise. Training uses preparation commands; the classifier is frozen before it processes separate held-out and unknown shots. Unknown shots contain raw ADC codes and times.Compare Decay during readout with A noisy line, then try Excess probe power.
What to observe: A longer average reduces white noise and allows more time for relaxation. Excess model power, failed calibration or an ADC endpoint preserves the data and withholds assignments, the matrix and the score.Keep acquisitions at different settings, select an older record, then use Reset circuit.
What to observe: Reset restores the current circuit parameters. Old records retain their calibration, frozen classifier and raw signals. JSON and CSV reconstruct the same acquisition.How physics instruments measure · Reading path
Articles on this path that use this experiment, followed by the other experiments they suggest.
Condensed matter · Reading path
Articles on this path that use this experiment, followed by the other experiments they suggest.
Condensed matter · Reading path
Articles on this path that use this experiment, followed by the other experiments they suggest.