Tokamak Magnetic Confinement and Heat Measurement

How does a magnetic field contain plasma, and how can an experiment measure its heat? Toroidal and poloidal magnetic fields combine into twisting field lines on magnetic surfaces. Electron scattering broadens the laser spectrum as temperature rises. Independent calibration and supplied density and temperature profiles connect that spectrum to electron thermal energy, which can be compared with heating input and cooling losses.

Follow closed magnetic surfaces and move a laser chord across the plasma. Compare electron scattering spectra, heating input and material energy losses as the electrons heat and cool.

Interactive modelTokamak Magnetic Confinement and Heat Measurement

Read how magnetic confinement, heating and diagnostics connect

Magnetic surfaces and measured plasma heat

BackgroundCharged particles gyrate around magnetic field lines. A tokamak combines toroidal and poloidal fields so the lines wind around a torus on magnetic surfaces.

Why it mattersMagnetic confinement and heating have different jobs. Scattered laser light probes electron motion; material terminals record where heat leaves the plasma.

Focus question
How can magnetic geometry be connected to measured electron heat?
One-sentence intuition
Magnetic surfaces describe the supplied field; calibrated scattering spectra determine electron temperature, density and heat.

Core mathematical model

Toroidal and poloidal magnetic field

B=∇ψ×eϕ+F(ψ)eϕR\mathbf B=\frac{\nabla\psi\times\mathbf e_\phi+F(\psi)\mathbf e_\phi}{R}

The flux function gives the poloidal field and a second function gives the toroidal field. This apparatus holds a supplied cold fixed boundary and admits only a passive thermal perturbation.

Heating and losses change thermal energy

dWdt=Paux+Pα,supplied−(τcond−1+λrad)W\frac{dW}{dt}=P_{\mathrm{aux}}+P_{\alpha,\mathrm{supplied}}-\left(\tau_{\mathrm{cond}}^{-1}+\lambda_{\mathrm{rad}}\right)W

Conduction and radiation remove heat. Their coefficients are supplied inputs; the measurement still reconstructs changing heat and terminal energies from independent readouts.

Electron temperature broadens scattered light

x=ωs−ω0ω0,σx2=∣ns−ni∣2eTemec2x=\frac{\omega_s-\omega_0}{\omega_0},\qquad\sigma_x^2=|\mathbf n_s-\mathbf n_i|^2\frac{eT_e}{m_ec^2}

Electron temperature is expressed in electronvolts. Known mean drift is included separately from random motion. Finite aperture, spatial profiles and spectrometer broadening are integrated before pixel binning.

Electron heat and conditional total heat

We=32e∫neTe dV,W=2Weonly if Ti=TeW_e=\frac32e\int n_eT_e\,dV,\qquad W=2W_e\quad\text{only if }T_i=T_e

Thomson scattering diagnoses electrons. Ion heat needs another measurement or a supplied closure. Doubling electron heat here assumes equal ion and electron temperatures.

Common difficulties

Do closed surfaces establish stability?

Typical misconceptionClosed magnetic surfaces prove that a plasma is stable.

Better mental modelThey describe the supplied field geometry. Stability requires perturbation dynamics; a static flux-correction bound does not determine those dynamics.

Does the laser measure ion heat?

Typical misconceptionElectron temperature gives a direct measurement of all plasma heat.

Better mental modelThomson scattering diagnoses electrons. The displayed ion-inclusive heat requires the supplied equal-temperature closure.

Run the experiment

  1. 01

    Inspect the winding field

    Choose the magnetic view and adjust Magnetic scale and Elongation.

    What to observe: The same flux function generates the surfaces. Heating leaves this supplied cold reference geometry fixed.
  2. 02

    Compare heating and cooling

    Choose Heating pulse, then Free cooling. Inspect electron heat over time.

    What to observe: Input competes with losses during heating. Conduction and radiation continue after the input stops.
  3. 03

    Distinguish heat-loss channels

    Compare Stronger radiation and Faster conductive loss, then expand the terminal measurements.

    What to observe: Both can accelerate cooling. Bolometric, wall and divertor readings distinguish how energy leaves.
  4. 04

    Move the laser off axis

    Choose Off-axis chord or drag the laser-chord handle. Compare the laser-on and laser-off pixels.

    What to observe: Finite beam and receiver areas select a spatial mixture. Profile and absolute references support reconstruction; brightness alone cannot determine temperature.
  5. 05

    Check reference coverage

    Choose Late reference and compare early and late readouts.

    What to observe: Pixels outside reference coverage remain available. Dependent temperature and heat estimates are withheld.

Related experiments and articles

What this page links to directly

You are hereTokamak Magnetic Confinement and Heat Measurement

Articles

How physics instruments measure · Reading path

How physics instruments measure

Articles on this path that use this experiment, followed by the other experiments they suggest.

  1. ArticleHow a tokamak holds heat and measures where it goes
Something broken, confusing, or missing on this page?Tell us