A long, faint tail.
Cyan: efficiency-scaled model rate. Gold: timestamp histogram per trial. Drag the gold gate; arrows move it.
·
COLLECTIVE LIGHT / THE QUIET SIDE
Share one excitation across an atomic chain. Turn neighboring amplitudes out of phase, watch radiation cancel, then break the protection by increasing the spacing. Inspect the emission lobes and timestamp statistics.
Dots: site excitation; hand direction: complex-amplitude phase. Physical chain lies on x, dipoles on z. Surface: angular intensity, not a spatial wavefront.
REPEAT THE PREPARATION. RECORD THE LIGHT.
Each trial starts fresh and records the full time window. Ideal full-solid-angle photon counting, followed by the selected efficiency. No-click trials stay in the denominator.
Recorded clicks per trial
Trials with a click
Model click probability
Model excitation at the gate
Cyan: efficiency-scaled model rate. Gold: timestamp histogram per trial. Drag the gold gate; arrows move it.
·
Cyan: remaining excitation fraction. Coral: independent-emitter reference. Pale vertical: selected scene time. Gold: analysis gate.
·
Equatorial cut of the 3D surface, in the plane perpendicular to the dipoles. Radius is linear here. This is a model diagnostic; the timestamp counter collects all directions.
Last 40 trials. Each mark is a detected photon; empty rows are retained. The full ledger and all timestamps are exported.
| Trial | Clicks | Timestamps · |
|---|
Time uses the isolated-emitter population lifetime. The counter has full solid-angle coverage and independent detection loss. No background, dead time, timing jitter or technical preparation error. Intervals describe sampling uncertainty only.
Finite fixed chain along x; parallel dipoles along z. The vector Green tensor includes coherent exchange and collective radiative decay. A matrix exponential evolves the unnormalized single-excitation state; norm loss is emitted probability. Zero diagonal coherent shift defines the rotating frame. No nonradiative loss, motion or retardation beyond the Markov Green tensor.
The default 3D radius uses a cube-root gain and is an angular diagnostic, not a distance. Enlarge shape explicitly normalizes each frame to reveal weak lobes; compare the numerical rate for actual strength. Its fixed intensity reference is the maximum Dicke ladder rate at 32 atoms, or 12 times the single-dipole maximum for the array. The equatorial 2D plot is linearly scaled with its maximum printed. Atom dots are a separate schematic state diagram, not a detector surface.
Actual preparation and numerical diagnostic:
The diagnostic compares survival loss with the time integral of emission, using a finite trapezoidal step. It is a quadrature residual, not a physical loss. Photon times invert the survival curve on a fine grid.
Holzinger et al. — Dicke decay, Eqs. 1–6 & quantum trajectories
Piovella — vector Green tensor, Eqs. 24–27 & 38
Lehmberg — radiation from an N-atom system
Physics tutorial
BackgroundShare one excitation across an atomic chain. Turn neighboring amplitudes out of phase, watch radiation cancel, then break the protection by increasing the spacing. Inspect the emission lobes and timestamp statistics.
Why it mattersThe same number of excitations need not produce the same light pulse.
Start with the essentials
The vector Green tensor supplies dissipative and coherent couplings. Frequencies are in isolated-atom decay units.
The lost excitation is radiated into the full solid angle. A finite chain does not have a perfectly dark initial phase ramp.
Typical misconceptionNo click means the excitation is definitely still present.
Better mental modelThe detector may miss an emitted photon. The model survival and observed no-click fraction are separate quantities; only sampling uncertainty is shown.
Compare In phase and Alternate at two single-atom lifetimes.
What to observe: The alternating preparation retains most excitation while the in-phase preparation radiates rapidly.Increase the spacing or displace one site. Inspect both survival and directionality.
What to observe: The result follows the selected state and geometry, not a fixed animation.Collect 200 full decay trials. Drag the time gate, pin the data, change the preparation and restore. Export timestamps, including no-click trials.
What to observe: Detection inefficiency can also produce silence. Compare the measured click probability with the efficiency-aware model.