Twist a coherent spin
The full symmetric spin sector is retained. Magnetic-number amplitudes acquire quadratic phase; they are not sampled as classical spin directions.
Q051 · THE PRICE OF PRECISION
Twist a small atomic ensemble and rotate the readout direction. Compare its phase estimates with independent atoms using exactly the same atom and shot budgets.
Horizontal · Upward
PROJECT ONTO THE GOLD LINE
Circle: independent atoms. Filled ellipse: twisted state. A narrow shadow helps only if enough signal remains.
Protocol and second-moment diagram; not an atom image or simultaneous measurement of two spin components.
Ready. No measurements yet.
02 / WHAT WAS ACTUALLY RECORDED
Population difference along the readout axis; frequencies are counts divided by shots.
03 / CHECK THE PRECISION
Local model reference at zero phase
Fresh estimates · twenty shots per estimate
Each estimate uses the recorded mean and a separately known zero-phase slope. The applied phase is used only to score error. This local linear estimator can be biased away from zero. Incomplete groups remain in raw CSV but do not enter RMSE.
Latest twelve shots shown; CSV retains all outcomes and settings. Save up to six samples and restore their exact settings and records.
Single collective-spin sector, ideal rotations and number detection. Twisting is followed by alignment, phase sensing with Gaussian collective jitter, and a final readout rotation. No Gaussian-state approximation is used for the count distribution. The plotted ellipse summarizes only the covariance. Calibration cost and preparation time are excluded from the equal atom-shot budget.
Physics tutorial
BackgroundTwist a small atomic ensemble and rotate the readout direction. Compare its phase estimates with independent atoms using exactly the same atom and shot budgets.
Why it mattersChange one physical ingredient and keep a matched control.
Start with the essentials
The full symmetric spin sector is retained. Magnetic-number amplitudes acquire quadratic phase; they are not sampled as classical spin directions.
Variance is evaluated after alignment and collective phase diffusion at zero phase. Below one beats the ideal independent-atom projection-noise reference locally; it is not a finite-record guarantee.
A known zero-phase slope calibrates the sample mean. Twenty shots form one estimate; both ensembles use the same atoms and number of estimates. Scoring alone uses the applied phase.
Typical misconceptionEvery plotted quantity was measured.
Better mental modelHistograms and phase estimates use sampled counts. The covariance ellipse and local sensitivity are separate model references.
Typical misconceptionA small ideal model certifies a laboratory advantage.
Better mental modelPermutation-symmetric spin model with 4–40 ideal two-level atoms. Collective Gaussian phase jitter is included; particle loss and local decoherence are omitted. The noise ellipse shows second moments, not a joint measurement. Local sensitivity and finite-sample error are different quantities.
Start with independent atoms; rotate the readout axis.
What to observe: The transverse noise is circular and the local precision is unchanged.Add modest twisting, align the narrow direction, and record both ensembles.
What to observe: Compare the local sensitivity reference with errors from repeated finite groups.Over-twist, add phase jitter, or increase the test phase away from zero.
What to observe: Contrast loss, classical noise and estimator bias can erase the apparent gain.