Coherent angular amplitude
Polar angle is measured from the incoming positive x direction. The laboratory drawing uses x as the beam axis.
Q016 · Phase / angle / cross section
Send a monoenergetic beam toward a central potential. Move an annular detector, count scattered arrivals, and separate interference in the angle distribution from a change in total scattering.
02 / RECORD BEFORE EXPLAINING
· Blue: active. Amber: most recent other saved sample. Drag to select a probe setting.
Each cell is one exposure. Darker cells contain more counts. Whiskers are approximate 95% Poisson score intervals; the detector reports a polar-band average.
03 / CONNECT SHAPE TO THE RESULT
· This decomposition is a model diagnostic, not a measurement of individual partial waves.
The final three partial waves provide a tail diagnostic. Convergence is also checked by adding eight more waves in scientific tests.
MODEL INSPECTION · SEPARATE FROM COUNTS
· Solid: coherent sum. Dashed: sum of squared components after discarding cross terms. The dashed curve is a diagnostic, not a second physical scattering model.
04 / KEEP THE EVIDENCE
Up to eight frozen samples. Restore to inspect the original settings. New acquisition after saving starts another sample. CSV contains all zero outcomes as well as successful detections.
A real, finite-range central potential and elastic electron-mass scattering. The incident plane wave travels along positive x. The annular detector accepts every azimuth and a polar interval excluding two-degree beam ports at each pole. Radius and depth define a hypothetical target; no specific material is implied. The hard-sphere option replaces the interior by a zero-wavefunction boundary.
The partial-wave cutoff increases with incident momentum and radius. Detector integration uses Gaussian quadrature; independent angular exposures follow Poisson counting. The displayed dot set is at most 128 conditionally sampled arrivals from the last exposure. The raw CSV retains each full exposure count and fluence. Target recoil, absorption, inelastic channels, multiple scattering and Coulomb tails are omitted.
Fitzpatrick · Partial waves · Phase shifts · Resonant scattering
Physics tutorial
BackgroundSend a monoenergetic beam toward a central potential. Move an annular detector, count scattered arrivals, and separate interference in the angle distribution from a change in total scattering.
Why it mattersA symmetry constrains the amplitude. Measure its consequences, then change one part of the preparation.
Start with the essentials
Polar angle is measured from the incoming positive x direction. The laboratory drawing uses x as the beam axis.
An annulus accepts all azimuths and a finite polar band. Recorded counts divide by exposure and solid angle; they estimate a bin average, not a point value.
Elastic real potentials conserve flux. Angular quadrature and the optical theorem must agree with the partial-wave sum.
Typical misconceptionThe outgoing guide is a calculated classical orbit.
Better mental modelThe guide connects the scatterer to an accepted angle. Complex waves, not classical paths, determine counts.
Typical misconceptionA numerical pass proves a real apparatus has been reproduced.
Better mental modelElastic, nonrelativistic scattering with electron mass from an attractive spherical square well or hard sphere. Independent Poisson exposures, uniform incident fluence and ideal annular detection. No Coulomb tail, target recoil, absorption, multiple scattering or calibrated material potential.
Predict whether a larger circular target can produce angular minima. Record an angular scan.
What to observe: Empty charts are empty evidence. Reference curves stay separate until explicitly enabled.Compare low energy and multi-wave presets. Broaden the detector and repeat at the same angle.
What to observe: A wide aperture washes out narrow minima; cross section and a conditional angle distribution are different observables.Remove the potential. Zero counts are still recorded exposures. Compare an impenetrable sphere separately.
What to observe: Export the raw records, including zero outcomes, and reproduce the displayed estimator.