IN33 · Read a magnetic field from dimmer fluorescence

NV-center magnetometer

How can a dimmer diamond reveal the direction of a magnetic field? Microwaves dim the fluorescence when their frequency matches a spin transition. A magnetic field splits the transitions differently along each diamond axis. Several known axes and a known bias can determine a local field vector. A common frequency shift also responds to temperature and strain.

Rotate a magnetic source and retain a counted microwave sweep. Separate common resonance drift from a field inferred with independently measured references.

Interactive modelNV-center magnetometer

Simulated detector counts · retained frequency gates

The resonance is a dip in photon counts

One fluorescence signal supplies these counts. The enlarged NV structure is a model.

Counted frequency sweep · zoomed count scale

N/(103 photon)N/(10^3\,\mathrm{photon})

f/MHzf/\mathrm{MHz}

Observed countsOne joint fitted spectrum

References, timing and every counted gate

The counter sees one collected fluorescence signal. The curve below is fitted to its saved counts; the enlarged NV structure above is a model.

Counter-based frequency calibrationf=affcmd+bff=a_f f_{\mathrm{cmd}}+b_f
Measured reference splittingDref=2870 MHzD_{\mathrm{ref}}=2870\,\mathrm{MHz}
Fitted individual hyperfine linewidthΓ=1.2 MHz\Gamma=1.2\,\mathrm{MHz}
Raw synchronous frequency gates and photons
fcmd/MHzf_{\mathrm{cmd}}/\mathrm{MHz}tstart/st_{\mathrm{start}}/\mathrm stend/st_{\mathrm{end}}/\mathrm sN/photonN/\mathrm{photon}

Each frequency is held for its recorded gate. The animation replays gates faster than acquisition time; it is not a new measurement. The clock starts at instrument time zero. CSV retains sample, reference and withheld check scans, frequency-counter pulse totals and gates, dark counts, axes, bias, versions, units, seeds and flags.

Separate generating reference

The input field and temperature describe the synthetic source. They do not enter the inverse or raw CSV/JSON.

∥Bin∥=65 μT\lVert\mathbf B_{\mathrm{in}}\rVert=65\,\mathrm{\mu T}
Hamiltonian, branch assumptions and primary sources
H/h=DSz2+γB⋅S+E(Sx2−Sy2)H/h=D S_z^2+\gamma\mathbf B\cdot\mathbf S+E(S_x^2-S_y^2)
3 n1=(1,1,1),3 n2=(1,−1,−1),3 n3=(−1,1,−1),3 n4=(−1,−1,1).\begin{aligned}\sqrt3\,\mathbf n_1&=(1,1,1),\\\sqrt3\,\mathbf n_2&=(1,-1,-1),\\\sqrt3\,\mathbf n_3&=(-1,1,-1),\\\sqrt3\,\mathbf n_4&=(-1,-1,1).\end{aligned}

The complete electronic spin matrix retains transverse fields. Each electronic group is a symmetric equal-population nitrogen-14 triplet, spaced by 2.16 megahertz; transverse nuclear mixing and unequal nuclear populations are omitted. Fluorescence uses a weak-CW Lorentzian model. The four-axis fit is local to a measured known-bias reference, with an increment norm at most 150 microteslas and stable zero transverse strain. The single-axis unknown is assumed axial.

A common zero-field splitting shift can mean temperature or axial strain. A conditional temperature estimate assumes stable axial strain; no sensitivity or certified uncertainty is inferred. Azimuth is hidden below a conservative five-microtesla display guard, not a sensitivity specification. Photon sampling uses a normal approximation above forty. The low-rate detector model neglects dead-time correction only below one percent occupancy; shot noise is included, laser drift and calibration systematics are not. The 532-nanometre excitation and red fluorescence pass through ideal finite optics. Collection uses an air-side equivalent isotropic point source and fixed efficiency; internal refraction and total internal reflection are omitted. The remote source is an ideal dipole; external bias hardware is shown by its supply. Crystal scale, photon animation and mechanical supports are schematic.

Physics tutorial

Read frequency before interpreting a field

BackgroundGreen light prepares an NV ensemble and makes it fluoresce red. Resonant microwaves transfer population into a less fluorescent spin state.

Why it mattersThe detector counts light; the magnetic field is inferred from where that light dims during a frequency sweep.

Start with the essentials

Focus question
Which information fixes a field component, and which information is needed for a vector?
One-sentence intuition
The two branches separate magnetic splitting from common drift; a vector also needs independently known axes and a resolved bias branch.

Core mathematical model

Electronic spin Hamiltonian

H/h=DSz2+γB⋅S+E(Sx2−Sy2)H/h=D S_z^2+\gamma\mathbf B\cdot\mathbf S+E(S_x^2-S_y^2)

The local quantization direction follows an NV axis. The zero-field and strain parameters describe the electronic level structure. The instrument diagonalizes the full electronic matrix; nuclear dynamics are represented only by a declared secular triplet.

Axial small-field limit

f±≃D±γB∥,γ=0.028 MHz/μTf_\pm\simeq D\pm\gamma B_\parallel,\qquad\gamma=0.028\,\mathrm{MHz/\mu T}

Half the separation gives an axial projection in this limit. A common midpoint shift can come from temperature or axial strain. Transverse fields add shifts that the vector calculation retains.

A finite collection cone

ηΩ=1−cos⁡α2\eta_\Omega=\frac{1-\cos\alpha}{2}

This fraction follows air-side equivalent isotropic point emission; internal diamond refraction is omitted. It gives the fraction entering the stated objective cone. A fixed detector efficiency and a separately counted dark rate complete the synthetic counting chain.

Common difficulties

Brightness and frequency

Typical misconceptionDarker light means a stronger magnetic field.

Better mental modelBrightness also depends on collection, pumping and contrast. Resonance frequencies, fitted from counts, carry the field information.

Axis and sign information

Typical misconceptionEight spectral groups uniquely identify a vector in any orientation.

Better mental modelUnsigned frequencies permit sign and axis ambiguities. This inverse uses a known crystal frame, a measured reference under known bias and a bounded local increment.

Shared shifts

Typical misconceptionEvery shared shift measures temperature.

Better mental modelTemperature and axial strain both shift the zero-field splitting. The conversion needs an additional stable-strain assumption.

Run the experiment

  1. 01

    Follow the light

    Use the sensor view and identify the diamond, objective, red filter and photon counter.

    What to observe: Green excitation reflects toward the specimen. Red fluorescence passes through the dichroic and reaches one finite detector face.
  2. 02

    Rotate the source

    Hold the gold source handle and move it horizontally.

    What to observe: The actual source moment and its field at the diamond change. A fresh counted spectrum gives different line-group positions.
  3. 03

    Compare one axis with four

    Choose the single-axis preset and then the vector preset.

    What to observe: The single-axis result is conditional on an axial unknown. Four axes add independent projections within the known-bias branch.
  4. 04

    Separate drift from splitting

    Choose the thermal-shift preset.

    What to observe: The groups move together as well as retaining magnetic separation. The inferred common zero-field splitting shift has a temperature interpretation only if axial strain is stable.
  5. 05

    Remove an assumption

    Remove the bias, then inspect the strain challenge.

    What to observe: The raw counts remain visible while a unique field conclusion is withheld.
  6. 06

    Keep and replay

    Keep one cycle, change the source, and select the earlier record before exporting CSV.

    What to observe: Earlier counts and their references remain unchanged. CSV includes the complete sample, reference and withheld sweep plus frequency-counter and dark records.

Related experiments and articles

How physics instruments measure · Reading path

How physics instruments measure

Articles on this path that use this experiment, followed by the other experiments they suggest.

  1. ArticleHow diamond fluorescence reveals a magnetic-field direction