Skip to main content
Sandbox Physics

KITAEV WIRE / LOCAL SPECTRAL SCANNING

Majorana End Modes

Move a spectral probe along a superconducting chain. Find the near-zero-energy weight at its ends, close the bulk gap, and watch the endpoint signal disappear. Resolve the finite-size spectrum and collect an ideal local energy distribution.

Interactive modelMajorana End Modes
A SPECTRAL PORTRAIT OF A QUANTUM WIRE

LOWEST EXCITATION ENERGY

00

PROBE AT THE GOLD MARKER

00
CYAN · ELECTRONCORAL · HOLEHEIGHT · LOCAL SPECTRAL DENSITY

Both ribbons share the same physical sites. Their separation is a display convention. Height is linear spectral density at the selected energy; gain is fixed. Drag the probe strip below.

j=1j=1
00

01 / POSITION × ENERGY

Find the hidden endpoint weight.

Electron spectral density: position left to right, energy −3.5 at the bottom to 3.5 at the top. Drag the crosshair to set both probe and energy. Square-root color, fixed scale from 0 to 3 per hopping energy.

DARK 0 → BRIGHT 3 · linear values in the charts

02 / A LOCAL LOOK

The edge and the middle tell different stories.

Cyan: electron spectrum at your probe. Dashed gray: middle site. Gold: selected energy. Lorentzian half-width is 0.06; its tails extend beyond the displayed window.

E/J ⟶Jρj(E)E/J\ \longrightarrow\quad J\rho_j(E)

03 / FINITE WIRE

Keep the actual levels in view.

Every dot is a finite-chain BdG eigenvalue. Gold marks the two closest to zero; gray shading is the infinite-chain bulk gap. A finite-chain excitation energy is not a many-body parity measurement.

n ⟶En/Jn\ \longrightarrow\quad E_n/J

04 / INDEPENDENT BULK REFERENCE

Close the gap. Change the phase.

Analytic positive and negative bands of the infinite uniform chain. This is a reference, not a reconstruction of the local records.

k ⟶E/Jk\ \longrightarrow\quad E/J

TURN THE MODEL INTO RECORDS

Collect a local spectrum.

0 / 8000

Ideal samples from the normalized electron spectral measure at the probe, with Lorentzian energy resolution. These are simulated energy records, not measured tunnel currents. The selected display energy does not filter the sample. Fixed reproducible seed; all tails retained in CSV.

Recorded near-zero fraction

—\text{—}

95% Wilson interval · shot noise

—\text{—}

Model probability

—\text{—}

All-eigenpair residual

—\text{—}

Records in gold. Model in cyan.

The central window is −0.15 to 0.15. Histogram bins cover −3.6 to 3.6; the outer bins include all overflow. Each bar is a fraction of every recorded trial.

Latest 20 records · export every trial
TrialSiteE/JE/J
Model, units and sources

Real nearest-neighbor hopping, open ends, uniform spinless p-wave pairing, no disorder. The full real symmetric BdG matrix is diagonalized; all eigenpairs enter the spectra. Broadening is a resolution kernel, not a fitted lifetime. Excitation energies below one ten-billionth of the hopping are reported as unresolved.

Position increases to the right in lattice-spacing units. Hopping sets the energy unit; time is measured in reduced Planck constant divided by hopping. Ribbons are a diagnostic representation, with schematic spacing between components.

H=(hD−D−h),hjj=−μ,hj,j+1=−J,Dj,j+1=−Dj+1,j=ΔpH=\begin{pmatrix}h&D\\-D&-h\end{pmatrix},\quad h_{jj}=-\mu,\quad h_{j,j+1}=-J,\quad D_{j,j+1}=-D_{j+1,j}=\Delta_p

The real-space matrix and bulk dispersion are separate finite and infinite models. The topological regime of this uniform ideal chain has nonzero pairing and chemical potential magnitude below twice the hopping. A near-zero spectral peak alone is not a general material diagnostic.

Sources: Kitaev’s original wire model and the BdG formulation in the Kwant superconductivity tutorial.

Physics tutorial

Majorana End Modes

BackgroundMove a spectral probe along a superconducting chain. Find the near-zero-energy weight at its ends, close the bulk gap, and watch the endpoint signal disappear. Resolve the finite-size spectrum and collect an ideal local energy distribution.

Why it mattersConnect a visible change to the spectrum of a superconducting system.

Start with the essentials

Focus question
A gapped wire. Two luminous ends.
One-sentence intuition
The ideal topological wire has near-zero modes at its boundaries while its bulk remains gapped.

Core mathematical model

Electron and hole amplitudes

iℏ∂t(uv)=HBdG(uv)i\hbar\partial_t\begin{pmatrix}u\\v\end{pmatrix}=H_{\mathrm{BdG}}\begin{pmatrix}u\\v\end{pmatrix}

These are two components of a quasiparticle, not independent physical paths.

Infinite-chain spectrum

E(k)2=(μ+2Jcos⁡k)2+4Δp2sin⁡2kE(k)^2=(\mu+2J\cos k)^2+4\Delta_p^2\sin^2 k

The bulk gap closes at chemical potential magnitude twice the hopping. A finite chain retains a discrete spectrum.

Common difficulties

Respect the scope

Typical misconceptionAny zero-bias peak proves a Majorana particle.

Better mental modelThe ideal spinless p-wave Kitaev chain, with open ends and prescribed pairing. A local zero-energy peak alone does not establish Majorana modes in a material. No braiding, qubit operation, disorder, interactions or experimental identification is simulated. Spectra use a declared Lorentzian resolution.

A diagnostic is not a photograph

Typical misconceptionThe raised ribbons are paths followed by individual particles.

Better mental modelRibbon height encodes a declared probability or spectral density. The two colors share the same physical site coordinate.

Run the experiment

  1. 01

    Make a prediction

    Compare the three presets, then change one continuous control.

    What to observe: The endpoint peak vanishes as the wire becomes trivial.
  2. 02

    Inspect the cause

    Move the probe from an end to the center; scan energy across the gap.

    What to observe: Local spectral weight is not the same at the boundary and in the bulk.
  3. 03

    Acquire evidence

    Collect repeated records, inspect the histogram and interval, then export the complete CSV.

    What to observe: The model curve is a separate reference. Only recorded events build the gold histogram.
FeedbackSomething broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy