Two flashes in a dual-phase xenon TPC

How do two flashes locate an energy deposit? The first flash marks the energy deposit. Electrons then drift into gas and produce a second flash. Their time separation gives depth after drift-speed calibration, and the upper light pattern helps locate the deposit sideways.

Follow electrons from liquid xenon into gas, compare the timing and light patterns, and use independent standards to estimate position and visible energy.

Interactive modelTwo flashes in a dual-phase xenon TPC
S1 · prompt lightElectrons drift upwardS2 · gas light after drift

Blue and gold distinguish two ultraviolet flashes in the model.

Drag a gold handle. Arrow keys move X/Y, Shift changes depth, Alt changes energy.

Locate an energy deposit from two flashes

BackgroundAn energy deposit leaves light and free electrons in liquid xenon. Prompt light forms S1. Electrons drift upward, enter the gas and gain energy from the electric field. Their excitation of xenon produces S2, making a small charge easier to read.

Why it mattersA deeper deposit gives electrons a longer journey. An uneven upper light pattern provides another clue. Calibrated timing and light collection turn these clues into position.

Focus question
What happens to the second flash when the deposit is deeper?
One-sentence intuition
Drift time provides depth and the S2 pattern provides transverse position, after accounting for the detector response.

Core mathematical model

Liquid drift time determines height

z=zg−vdtbulkz=z_g-v_d t_{\mathrm{bulk}}

Height is zero at the liquid surface and positive upward. The gate lies below the surface; calibration supplies the liquid drift speed. Separate terminal transport, gas-light timing and the mean prompt delay from the difference of the two measured centroids. The mean gas-light delay also depends on the transverse candidate position.

The field pays for gas scintillation

Nγ,ELhcλ≤NexteVgN_{\gamma,\mathrm{EL}}\frac{hc}{\lambda}\leq N_{\mathrm{ext}}eV_g

Extracted electrons gain electrical work across the gas voltage. Part becomes ultraviolet photons, whose energy is Planck’s constant times light speed divided by wavelength. Other energy remains in unobserved channels. Emitted photons differ from detected photoelectrons; one vacuum-ultraviolet photon can release two photoelectrons.

Common difficulties

Does more gas light mean a larger original deposit?

Typical misconceptionAll S2 light energy came from the initial particle.

Better mental modelElectrons obtain additional energy from the gas electric field. Calibration converts the amplified light signal back to charge before drift.

Does an NR-like record identify dark matter?

Typical misconceptionA nuclear-recoil-like light-to-charge ratio identifies a dark-matter particle.

Better mental modelRecoil populations fluctuate, overlap and have backgrounds. This exercise compares two supplied partitions at a given visible energy, without event-class probabilities or total nuclear-recoil energy.

Run the experiment

  1. 01

    Separate prompt light from drifting charge

    Choose Central event, switch between the cutaway and surface views, and inspect the receiving curves.

    What to observe: The early narrow signal is S1; gas produces the later S2. The apparatus replays declared inputs. The curves retain the actual simulated counts in this exposure’s bins.
  2. 02

    Compare shallow and deep deposits

    Choose Near surface, then Deep event. Each preset acquires a record; switch between the saved records to compare them.

    What to observe: A longer liquid path delays S2. Independent interval and electron-injection standards help separate the clock scale and terminal transport delay.
  3. 03

    Move the deposit sideways

    Drag the transverse handle inside the liquid and acquire, or choose Bright off-centre.

    What to observe: The four upper fractions change. The search evaluates all 625 supplied cells. Its best cell is a conditional point; an engineering score is not confidence.
  4. 04

    Watch charge loss during drift

    Choose Short electron lifetime and compare with ordinary purity at a similar depth.

    What to observe: Attachment reduces the electrons reaching gas and accumulates along the drift. Energy estimation must account for collection, extraction and attachment.
  5. 05

    Change selection after saving the counts

    Open the extra settings, change the S1 threshold, and inspect the complete cell table and export.

    What to observe: Selection marks existing exposures. Counts, cell scores and point estimates remain unchanged. Zeros and saturation flags survive; animation supplies no missing clock or calibration.
Sources and detector references

Related experiments and articles

What this page links to directly

You are hereTwo flashes in a dual-phase xenon TPC

Articles

See every article series on the content map →

How physics instruments measure · Reading path

How physics instruments measure

Articles on this path that use this experiment, followed by the other experiments they suggest.

  1. ArticleWhy a xenon detector needs liquid and gas