Skip to main content
Sandbox Physics
Magnetars and X-ray polarization

Follow Stokes parameters along one ray

A weak magnetic field may turn linear polarization into circular polarization on a single ray. The total degree of polarization remains fixed in the lossless calculation.

Choose directions before assigning signs

Project the spin axis onto the sky and call that direction north for the model. A north–south line has positive Q, and the line turned forty-five degrees toward east has positive U. Circular polarization comes from the relative phase of the two perpendicular electric components. The model defines its sign as twice the imaginary part of the product of the north amplitude and the conjugate of the east amplitude.

pL=Q2+U2/I,ψ=12atan2⁡(U,Q)p_{\rm L}=\sqrt{Q^2+U^2}/I,\qquad \psi=\tfrac12\operatorname{atan2}(U,Q)

Check one retarder by following just two numbers

Imagine a field that projects north throughout the path. The relative phase rotates U into V while Q stays fixed. For two equal components initially in step, Q starts at zero and U starts at one if the intensity is normalized to one. An accumulated positive phase of a quarter cycle takes U to zero and V to one under the model’s convention.

The Lab applies the same rotation about each local magnetic direction. Its cold plasma is a dilute mix of equal electron and positron densities. The charges cancel the rotation that reverses sign with the charge. Their small linear delay still contributes. The atmosphere in the next reading is denser. Its resonance occurs at different depths for different photon energies.

Work it out

A fully polarized ray arrives with normalized Q equal to 0.6, U equal to zero and V equal to 0.8. What fraction is linear? Has it lost polarization?

Answer and explanation

The linear fraction is 0.6. The three-component vector has length one, so the ray is still fully polarized. The remaining component describes the rotation of the electric vector inside the ellipse.

Open the magnetar ray Lab

Sources

  1. Kislat et al., Analyzing the Data from X-ray Polarimeters with Stokes Parameters

    Sections 2–4 explain the doubled angle in the event estimator and the subtraction of background vectors.

  2. Lai and Ho, Transfer of Polarized Radiation in Strongly Magnetized Plasmas

    Section 2 and Figures 1–3 describe resonance, atmosphere density and photon-mode identities.

  3. Finite-field QED corrections to vacuum birefringence and magnetar polarization transport

    Equations 4–5 give weak-field indices and show where higher-order corrections enter.

Keep reading

What this page links to directly

See this series on the content map →

Magnetars and X-ray polarization · Reading path

From the polarization ellipse to IXPE events

  1. ArticleHow a magnetar changes the polarization of X-rays
  2. ArticleCalculate the phase delay in a magnetic vacuum
  3. You are hereFollow Stokes parameters along one ray
  4. ArticleRecalculate magnetar polarization from IXPE events
  5. ArticleRead a magnetar atmosphere’s vacuum resonance
Something broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy