Skip to main content
Sandbox Physics
Magnetars and X-ray polarization

How a magnetar changes the polarization of X-rays

A strong magnetic field can make one component of an X-ray electric field lag behind the other. Those components can arrive tracing an ellipse, even when they started in step along a straight line.

A line tells you when the two parts are in step

Imagine watching the tip of the electric vector while the wave passes. A linearly polarized wave traces a straight line. Pick two directions at right angles, one along the magnetic field projected across the ray. A straight line at forty-five degrees tells you the two components have equal amplitudes and reach their maxima at the same time.

If one component reaches its maximum a quarter cycle later, their sum keeps turning. With equal amplitudes it traces a circle. A smaller delay usually makes an ellipse. This is the same geometry you can see through a wave plate on an optical bench.

The magnetic field supplies the two directions

Without a field, the transverse directions are equivalent. Quantum electrodynamics gives the vacuum in a magnetic field a small direction-dependent response to a passing wave. The two electric-field components can have different phase speeds. The effect rises with the square of the transverse field at weak field strength.

On the Lab’s starting ray, the first station shows a line. The next few stations are enough to open it up. Select Plasma alone at the same phase to see what the stipulated dilute pair plasma would do by itself.

IXPE measured a change across energy bands

In 4U 0142+61, the low-energy and high-energy X-rays favor nearly perpendicular directions of linear polarization. Around 4–5 keV the signal was too weak to give a useful direction. A model of the source needs to predict how many photons reach each band and which directions they carry. The one-ray exercise isolates the propagation step.

Open the magnetar ray Lab

Sources

  1. Taverna et al., Polarized x-rays from a magnetar

    Figures 1–2 and Table S2 give the measured energy dependence. Figure S1 specifies the source and background regions.

  2. Finite-field QED corrections to vacuum birefringence and magnetar polarization transport

    Equations 4–5 give weak-field indices and show where higher-order corrections enter.

Keep reading

What this page links to directly

You are hereHow a magnetar changes the polarization of X-rays

Articles

See this series on the content map →

Magnetars and X-ray polarization · Reading path

From the polarization ellipse to IXPE events

  1. You are hereHow a magnetar changes the polarization of X-rays
  2. ArticleCalculate the phase delay in a magnetic vacuum
  3. ArticleFollow Stokes parameters along one ray
  4. ArticleRecalculate magnetar polarization from IXPE events
  5. ArticleRead a magnetar atmosphere’s vacuum resonance
Something broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy