Skip to main content
Sandbox Physics

Magnetar X-Ray Polarization

How can empty space turn the polarization of X-rays? In a strong magnetic field, quantum electrodynamics predicts different phase speeds for two directions of the electric field. The directions fall out of step as the X-ray travels. Their combination can turn a straight electric-field vibration into an ellipse.

The electric field traces a line at the start. Follow the same ray to see where that line becomes an ellipse, then compare with the plasma-only calculation.

Interactive modelMagnetar X-Ray Polarization
Linear fraction73.0%73.0\%
Signed circular fraction−68.4%-68.4\%
Position angle52.8∘52.8^{\circ}
Model ray over one spin
Q/IQ/I
U/IU/I
V/IV/I

Watch relative phase turn a line into an ellipse

BackgroundThe electric field of a linearly polarized wave oscillates along a fixed line. Resolve it into two components. If their peaks reach you together, that line keeps its shape.

Why it mattersQuantum electrodynamics predicts slightly different phase speeds for two directions in a magnetic vacuum. X-rays can accumulate a measurable phase difference over a long path.

Focus question
What part of the default ray changes the polarization most?
One-sentence intuition
Most of the change is close to the first stations, where the transverse magnetic field is strongest.

Core mathematical model

Index difference in the weak-field limit

Δnvac=α30πB⊥2BQ2\Delta n_{\mathrm{vac}}=\frac{\alpha}{30\pi}\frac{B_{\perp}^2}{B_{\mathrm{Q}}^2}

Use the field perpendicular to the ray. Doubling it makes the vacuum index difference four times as large.

Accumulating phase along the path

Δφ=ωc∫Δn dr\Delta\varphi=\frac{\omega}{c}\int\Delta n\,\mathrm{d}r

This integral applies to a fixed pair of polarization directions. The Lab rotates the local directions between short segments as the field changes.

Recover linear polarization from Stokes values

ψ=12atan2⁡(U,Q),pL=Q2+U2I\psi=\tfrac{1}{2}\operatorname{atan2}(U,Q),\qquad p_{\mathrm{L}}=\frac{\sqrt{Q^2+U^2}}{I}

The angle is axial and repeats after half a turn. When both linear components vanish in the model, the angle is undefined.

Common difficulties

An ellipse still describes fully polarized light

Typical misconceptionA smaller linear fraction means that the light became unpolarized.

Better mental modelThis calculation is lossless. The electric vector still follows a definite path. The circular component accounts for the change.

Run the experiment

  1. 01

    Follow one ray

    Pause on the default preset and compare the first and final polarization shapes.

    What to observe: They start as a line. The two components reach the final station with a phase offset and trace an ellipse.
  2. 02

    Keep the same viewing angles

    Choose Plasma alone and compare the shapes at the same phase.

    What to observe: The stipulated dilute pair plasma has so little differential delay that the ellipses are almost straight lines.
  3. 03

    Test the zero-field limit

    Choose Turn off the field. Watch the model across a spin.

    What to observe: The polarization stays the same. Both birefringent terms vanish in this model.

Related experiments and articles

What this page links to directly

See every article series on the content map →

Magnetars and X-ray polarization · Reading path

From the polarization ellipse to IXPE events

Articles on this path that use this experiment, followed by the other experiments they suggest.

  1. ArticleHow a magnetar changes the polarization of X-rays
  2. ArticleCalculate the phase delay in a magnetic vacuum
  3. ArticleFollow Stokes parameters along one ray
  4. ArticleRecalculate magnetar polarization from IXPE events
  5. ArticleRead a magnetar atmosphere’s vacuum resonance
Something broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy