Skip to main content
Sandbox Physics
Matched filtering with GW150914

Why a strain record is whitened

Sandbox Physics ·

Whitening divides each frequency component by its usual noise amplitude. A fluctuation in a quiet part of the spectrum then counts for more than a fluctuation of the same strain amplitude in a noisy part.

Open the GW150914 analysis

Measure the noise away from the event

Take two seconds of data, subtract their mean, taper both ends, then Fourier-transform the samples. Squared Fourier amplitudes tell us how much variation occurs at each frequency. The power spectral density expresses that power per hertz. One short stretch has plenty of scatter, so slide the two-second window along nearby off-event data and average the estimates. Welch averaging in the LIGO–Virgo guide, §4.1

For GW150914, this exercise uses 25 overlapping segments from the first 14 and last 13 seconds of each 32-second file. In the published data-quality channels, all 32 seconds have data and pass the basic compact-binary quality mask. The windows purposely leave a gap around the known chirp. GWOSC technical details

Turn power into an amplitude weight

Write the one-sided noise density as Sn(f)S_n(f). Its square root is an amplitude spectral density. The white transform is proportional to

x~w(f)=x~(f)Sn(f).\widetilde{x}_{\mathrm{w}}(f)=\frac{\widetilde{x}(f)}{\sqrt{S_n(f)}}.

The scale convention of the discrete transform applies to every row the same way. Restrict it to the exercise band between 35 and 300 hertz, then transform back to get a trace in time. Outside the band the signal used by the comparison is zero. Neighboring samples remain correlated in the filtered time series.

Worked comparison

Suppose the noise power at one frequency is nine times the power at another. Equal physical strain amplitudes are then weighted in the ratio one to three after whitening. In a product of two whitened traces that becomes one to nine, which is the noise-power weight used in the matched filter.

Exercise. Why does the first 14 seconds provide more information about ordinary noise than just the sample at the event peak?

Answer. The peak mixes possible signal with noise. The off-event windows give many independent or partially overlapping views of ordinary variation without adding the strongest chirp cycles to the estimate.

Sources

  1. Welch averaging in the LIGO–Virgo guide, §4.1
  2. GWOSC technical details

Keep reading

What this page links to directly

See this series on the content map →

Matched filtering with GW150914 · Reading path

Matched filtering with GW150914

  1. ArticleHow to find a chirp in detector noise
  2. You are hereWhy a strain record is whitened
  3. ArticleWhat arrival time and chirp mass do to the match
  4. ArticleRecompute the GW150914 match from the public strain
  5. ArticleRead a frequency-consistency test for glitches
1 more group

Other articles that use the same experiments

Each experiment from this article that another series also uses, followed by the articles there.

  1. LabBinary Neutron Star Merger
  2. ArticleA pulsar clock revealed an orbit losing energy
Something broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy