Skip to main content
Sandbox Physics

Scanning Tunneling Microscopy and Spectroscopy

Why can an STM report a bump on a flat surface? At a fixed gap, extra electronic states can carry more tunnel current. In constant-current mode the tip lifts to bring the current back down, so a flat surface can appear raised. Two biases give different weights to those states and can help separate electronic contrast from height.

Scan a sample at constant height or constant current, then hold the tip for a local spectrum. Use two bias readings at each position to recover the surface profile.

Interactive modelScanning Tunneling Microscopy and Spectroscopy
Tunnel current0.909 nA0.909\,\mathrm{nA}
Differential conductance3.12 nS3.12\,\mathrm{nS}
Tip height0.634 nm0.634\,\mathrm{nm}
Vacuum gap0.634 nm0.634\,\mathrm{nm}

Simulated line scan

Recorded currentFlat reference
Recovered surfaceElectronic height
How the height is recovered

Each scan point records two extra currents at −0.12 V-0.12\,\mathrm V and +0.23 V+0.23\,\mathrm V at the same tip position. The biases weight the sample resonance differently, so the two readings determine a height and an electronic contribution for this calibrated sample model.

Ii=C e−2κ(z−h)(Bi+AGi)I_i=C\,e^{-2\kappa(z-h)}(B_i+A G_i)

The spectrum sweeps bias at the recorded lateral position and height, with feedback held. The feedback readout during a scan can lag behind either the geometric or the electronic change.

Read an STM bump

BackgroundA scanning tunneling microscope brings a conducting tip close to a conducting sample. The current depends on the gap and on which sample states can accept or supply electrons at the chosen voltage.

Why it mattersTwo regions of the same height can look different in a scan. A local spectrum gives a way to test where that contrast comes from.

Focus question
How can a flat surface make the feedback raise the tip?
One-sentence intuition
Extra states in the tunneling window raise the current at the same gap, so the feedback moves the tip up to recover the set current.

Core mathematical model

The vacuum gap sets the current scale

I∝e−2κd,κ=2meΦℏI\propto e^{-2\kappa d},\qquad \kappa=\frac{\sqrt{2m_e\Phi}}{\hbar}

At the same bias and on the same sample, increasing the gap by a fraction of a nanometer can cut the current sharply.

Voltage selects the states that contribute

I(V)∝∫ρs(E)[f(E−eV)−f(E)] dEI(V)\propto\int \rho_s(E)[f(E-eV)-f(E)]\,dE

At fixed gap, positive sample voltage opens a window above the sample Fermi level. The thermal occupation changes smoothly at the edges.

Common difficulties

Feedback height includes electronic contrast

Typical misconceptionEvery bump in a constant-current scan is a bump in the atoms.

Better mental modelFeedback also lifts the tip above a region that carries more current at the same gap. Two biases respond differently to the same local states and allow a model-based separation.

Run the experiment

  1. 01

    Scan a flat sample

    Choose “A bump on a flat surface”.

    What to observe: The recorded tip height rises while the surface recovered from the bias pair stays flat.
  2. 02

    Keep the tip height fixed

    Switch to “Constant height”.

    What to observe: The tip follows a horizontal line and a peak appears in the current at the same place.
  3. 03

    Stop over the peak

    Drag the tip to the peak, then select “Local spectrum”.

    What to observe: The tip stays at its recorded height while the bias changes. The conductance peaks when the bias is near the sample resonance.
Something broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy