The energy spectrum
Time is displayed as a fraction of this exact revival period. The rotor rotational constant is an energy.
QUANTUM TIME / A KICKED ROTOR
Kick an ideal molecular rotor with a short laser pulse. Rotate the three-dimensional axis distribution, find alignment revivals and slide a second pulse through the sequence. Collect independent axis readouts and compare their alignment with the model.
Preparing the spectrum…
FREEZE A MOMENT. BUILD THE EVIDENCE.
Each ideal readout uses a fresh identical preparation. Collecting pauses time.
MODEL / RECORDS / PINNED
Horizontal coordinate
Teal: model. Gold: recorded frequency density. Dashed: pinned model. Equal-width bins.
ALIGNMENT / AFTER THE PULSES
The dashed baseline is one third for an isotropic ensemble. Parallel and antiparallel axes are equivalent; this is alignment, not orientation.
Initially an isotropic rotational ground state. Two optional, collinear kicks add a phase proportional to the squared projection on the polarization axis. Free evolution includes angular momenta zero through 48. Pulse strength is dimensionless, not laser power.
All time labels use the revival period. Records sample the displayed 384-bin density, normalized for the ideal detector. No finite resolution, thermal ensemble or instrument response is modeled. Display brightness uses a fixed square-root gain.
Original research:Seideman (1999)
Physics tutorial
BackgroundKick an ideal molecular rotor with a short laser pulse. Rotate the three-dimensional axis distribution, find alignment revivals and slide a second pulse through the sequence. Collect independent axis readouts and compare their alignment with the model.
Why it mattersMake coherent time evolution visible, then test it with finite records.
Start with the essentials
Time is displayed as a fraction of this exact revival period. The rotor rotational constant is an energy.
A nonresonant pulse with positive polarizability anisotropy. The electric field is the envelope of the rapidly oscillating real field; both pulses share a polarization axis.
The sample mean of the squared axial projection estimates alignment. Head and tail remain equivalent; mean direction stays zero.
Typical misconceptionAn isolated linear rigid rotor initially in its rotational ground state. Collinear, instantaneous nonresonant kicks; no thermal mixture, centrifugal distortion, ionization or detector calibration. The surface shows axis probability, not a molecule or orbit.
Better mental modelThe radius encodes the square root of angular probability density. It is neither a molecule outline nor a trajectory. Thermal populations and a real probe require a different model.
Compare the instant of the pulse, a short time afterward and one full period.
What to observe: The pulse alone does not instantly align axes. Free evolution turns its phase imprint into a visible distribution.Enable the second pulse and drag its arrival time. Pin one sequence before changing it.
What to observe: Compare the entire time trace, not a single attractive frame.Collect 500 independent readouts. Pin the sample, change time, restore it and export the raw CSV.
What to observe: Counts fluctuate. The standard error describes sampling only; the teal reference comes from the model.