Specify the events being retained
Spontaneous parametric down-conversion shares pump energy between two output fields. We call their paths signal and idler. At low gain the chance of producing a pair per pump pulse is small. We first condition on exactly one pair. Most pulses still contain vacuum; two-pair and higher contributions require a photon-number model.
The joint spectral amplitude, or JSA, is after specified spatial and polarization collection. The subscripts label the two arms. Normalization makes the probabilities for all frequency combinations add to one. It does not set the pair rate.
Reading: P. J. Mosley et al. · A. Bhattacharjee et al.
Contributions from the crystal must add coherently
The pump spectrum restricts the sum of the two output frequencies. Pair creation can occur throughout the crystal. Contributions from those positions also need compatible phases to add constructively. Phase matching describes this condition. A finite crystal produces a finite matching width and a phase. Collection optics then select the spatial and polarization amplitudes that reach the experiment.
A scalar propagation approximation organizes these factors as the product below. Here is the complex pump envelope, is the phase-matching amplitude and represents the specified collection operation. These are amplitudes, so multiplying intensity pictures alone loses information.
Reading: P. J. Mosley et al.
Replace the continuum with orthogonal modes
Choose two orthogonal frequency modes in each arm. They might be normalized wave packets in nonoverlapping frequency intervals. Rows label signal modes; columns label idler modes. Each matrix entry is a complex amplitude. Its squared magnitude is the probability of that mode pair.
The coefficient is a projection of the continuous JSA onto mode functions. It is not simply a value at one frequency point. A sampled continuous integral needs quadrature weights absorbed into its discrete coefficients. Our two-mode experiment instead defines orthogonal discrete modes directly, with dimensionless coefficients.
Four equally bright entries
Set all four amplitudes to one half. Each mode pair has probability one quarter. Now rotate only the lower-right arrow through an angle . Every intensity stays fixed. The next chapter follows this change through to single-photon purity.
Pump, material and collection geometry determine which amplitudes a source can realize. Fixing one specified pair amplitude lets us ask how different herald measurements change the partner state. This separates the physical roles of source design and measurement selection.