A broad line can mean that each molecule loses coherence quickly. It can also mean that many molecules have slightly different frequencies. The first mechanism acts within an individual time evolution; the second spreads the phases across an ensemble. An echo separates these contributions by testing which phase spread can refocus.
A short pulse prepares related phases across many molecules. Represent each vibration by a rotating arrow. Their vector sum gives the macroscopic polarization, the collective electric-dipole response that radiates from the sample. Aligned arrows add strongly; dispersed arrows can nearly cancel.
A coherence describes an amplitude with a definite phase relation between quantum states. A population describes how much occupation an energy level has. Let T1 denote population relaxation time and T2 coherence decay time. Population loss contributes half its decay rate to the coherence rate.
T21=2T11+T2∗1
This is a simple two-level Markov model. The starred time denotes pure dephasing; no separate orientational relaxation is included.
If every molecule loses coherence at the same exponential rate, the broadening is homogeneous. A distribution of long-lived resonance frequencies instead causes inhomogeneous broadening: individual arrows keep rotating, but their sum decays. In liquids, those frequencies can change as environments evolve. We will call that spectral diffusion.
For a static Gaussian frequency distribution, write the angular-frequency offset as δω and its standard deviation as σω. Averaging the phase arrows gives a Gaussian envelope. An independent homogeneous decay multiplies that envelope.
⟨e−iδωt⟩=e−σω2t2/2,P(t)∝e−t/T2e−σω2t2/2
Offsets in radians per picosecond require times in picoseconds. The two factors describe different mechanisms.
Transform a decay into a line
Take the causal response e−t/T2e−iω0t and integrate over positive time. At resonance, successive contributions add in phase. Away from resonance, their phases spread. The real part of the following integral gives an absorptive line.
Re∫0∞e−t/T2ei(ω−ω0)tdt=(1/T2)2+(ω−ω0)21/T2
This Lorentzian has angular-frequency half width equal to the inverse coherence time. Converting its full width to wavenumber introduces the speed of light and a full-turn factor.
Set T2=1ps. The angular-frequency full width is 2radps−1, or about 10.6cm−1. If T1=2ps, population loss contributes 0.25ps−1 to the coherence decay rate. The remaining 0.75ps−1 is pure dephasing.
Adding a static frequency distribution broadens the line further. The inverse total linewidth can no longer be read directly as T2. An echo tests which part of the phase spread can return.
ΔνFWHM=πcT21=10.6cm−1
This conversion applies to the exponential coherence decay used here. A Gaussian distribution follows a different linewidth formula.
Increase static frequency spread and observe the faster loss of collective polarization.
Keep that spread fixed and compare rephasing with nonrephasing.
Shorten coherence lifetime and explain why the echo also becomes weaker.
Exercises and explanations
For a purely Lorentzian line, how does doubling coherence time change the wavenumber full width?
Read the explanation
It halves the width because the coherence time enters the denominator. The conclusion assumes exponential decay and does not directly describe static Gaussian broadening.
Can the macroscopic polarization nearly vanish while individual molecules still oscillate?
Read the explanation
Yes. Polarization is a phase-sensitive vector sum. Opposing contributions can cancel without each molecular vibration losing its energy.
Author lecture notes, nonlinear-spectroscopy section: density-matrix perturbation theory; printed pp. 23–25, Eqs. (51)–(55), for rephasing and nonrephasing; pp. 29–30 for the vibrational harmonic limit. The course examples are new teaching calculations.
Journal of Chemical Physics 135, 074502, publisher version, DOI 10.1063/1.3625278. Read Figs. 1–3 and Eqs. (1)–(4), (12), (14)–(15). The bounded numerical benchmark is the single-component Gaussian slope relation in Eq. (12), with original synthetic parameters; it is not a fit to the paper’s water measurements.