Skip to main content
Sandbox Physics
Cold liquids and superconducting order

Why flow and oscillation reveal different responses in superfluid helium

Why does the same helium flow easily through a narrow passage yet slow an oscillating object?

  1. Prepare cold liquid helium

  2. Drive flow through a narrow gap

  3. Compare with other responses

  4. Separate normal and superfluid motion

The narrow-gap experiment constrained dissipative flow. It did not imply that every probe of the liquid must see zero damping.

Why did two viscosity measurements disagree?

Push liquid helium through an extremely narrow passage and it can flow remarkably easily. Suspend an object in the same liquid and its twisting oscillations still decay. Interpreting both observations with one ordinary viscosity leads to a contradiction. The discovery of superfluidity became clear when experimenters recognized that the disagreement concerned the liquid’s response, not merely two inaccurate ways of measuring the same constant.

At ordinary pressure, helium-four undergoes the lambda transition near two point one seven kelvin. The name comes from the shape of its heat-capacity peak; the liquid has not frozen. The phases above and below are called helium I and helium II. In 1938 Kapitza’s narrow-gap measurements and Allen and Misener’s capillary experiments appeared side by side. Together they revealed a form of flow that called for a new description of the liquid.

Sources: [3][6]

A heat-transport puzzle led to a narrow passage

Kapitza initially wanted to understand helium II’s exceptionally strong heat transport. In an ordinary liquid, circulation can carry heat between places. Very low viscosity might allow unusually effective transport, but a heat measurement alone cannot determine viscosity. He therefore made a separate flow experiment, allowing helium to pass through a gap of about half a micrometer between polished surfaces and observing the changing liquid level.

The narrow geometry was meant to make viscous resistance important. In ordinary laminar flow, motion near a solid wall is constrained, and the velocity profile across a thin passage strongly limits the rate. A striking change across the transition in the same apparatus would therefore require an explanation. Gap width, driving head, temperature and possible bypass flow all mattered. Those conditions determine how a moving liquid level can be translated into a flow resistance.

Sources: [3][6]

An ordinary-flow law makes a sharp comparison

Take an ideal straight slit whose width greatly exceeds its thickness. Assume steady, fully developed flow, constant dynamic viscosity and no slip at its walls. The volume flow rate is then proportional to pressure difference and to the cube of the gap thickness. In the expression, width, thickness and flow length are measured in meters, pressure in pascals, dynamic viscosity in pascal seconds and volume flow in cubic meters per second. This is a comparison model for an ordinary viscous liquid.

Two consequences are easy to check. Doubling pressure difference doubles flow if everything else remains fixed. Halving gap thickness reduces flow by a factor of eight. Small geometric errors can consequently produce large errors in an inferred viscosity. Yet geometry was not the whole helium problem. Allen and Misener found that helium II’s flow response to applied pressure and capillary size departed from ordinary laminar expectations. The discrepancy concerned the relationship between flow and driving pressure itself.

Q=wa312ηL ΔPQ=\frac{w a^3}{12\eta L}\,\Delta P

Sources: [7][3]

A very small inferred viscosity is not the end of the analysis

Both groups faced a qualification: a laminar-flow formula requires laminar flow. If motion becomes unstable, the pressure drop also supplies other motion and dissipation. Inverting the laminar formula then loses its original interpretation. Kapitza explicitly considered whether the motion was laminar or turbulent. Historical evidence for an exceptionally small resistance and an experimental upper bound should not be rewritten as a measurement of a mathematically exact zero.

Temperature uniformity also matters. Flow and heat transport are coupled in helium II. A small heater, a thermal leak along a wire or evaporation can alter levels and pressure differences. Useful controls change temperature, driving pressure or channel geometry so that proposed explanations face different trends. When several apparatuses expose related failures of ordinary hydrodynamics, an accidental leak in one particular gap becomes a less adequate explanation of the combined observations.

Sources: [3][7][6]

The normal response explains why an immersed oscillator still slows

Two-fluid hydrodynamics permits two kinds of motion in the same liquid. The normal component carries entropy, has viscosity and can be dragged by solid boundaries. The superfluid component can flow without dissipation under appropriate conditions. In a sufficiently narrow passage, walls strongly impede the normal component while the superfluid component provides an easy route for mass flow. An immersed oscillator can still push the normal component and transfer energy to excitations, producing measurable damping.

The components are not two chemical liquids mixed in a cup, or two permanently labeled sets of atoms. They describe a decomposition of the liquid’s response whose proportions depend on temperature. Oscillation experiments can also measure added inertia from liquid moving with the apparatus. Period and damping then provide information different from a narrow-channel flow rate. Asking which motion a probe couples to turns the apparent contradiction into a set of testable physical questions.

Sources: [5][1]

Heat can move with almost no net mass transport

In a closed channel heated at one end, the entropy-carrying normal component can move toward the colder region. The superfluid component compensates in the opposite direction so that mass does not accumulate indefinitely. Ideally the two mass currents have equal magnitudes and opposite directions. Each density times velocity has units of kilograms per square meter per second. It is mass current that cancels; the two speeds need not have equal magnitudes.

This gives a route for strong heat transport without circulating the entire liquid in one direction. Another consequence appears when a porous plug impedes the normal component between two containers. Slight heating can draw superfluid into the warmer side and raise its pressure, producing the thermomechanical or fountain effect in a suitable apparatus. The fountain experiment is associated with Allen and Jones; it should not be attributed wholesale to Kapitza. Flow, oscillation and heating reveal different responses of the same liquid.

Sources: [5]

Reliable cooling was part of the discovery

These measurements required stable helium supplies, controlled temperatures and apparatuses sensitive to small flows. Kapitza’s work on liquefaction and low-temperature methods helped make sustained investigations practical. His 1978 Nobel Prize covered inventions and discoveries in low-temperature physics, a broader achievement than one narrow-gap experiment. Reducing the story to a claim that one person measured zero viscosity loses both the measurement logic and the contributions of independent experiments and subsequent theories.

These discoveries changed what a viscosity measurement meant. Narrow channels revealed an easy route for flow; oscillating objects coupled to thermal excitations and the normal response; heating showed that mass and heat currents could be arranged differently. The measurements described one liquid, with each probe selecting a different motion. Their coexistence and their changes with temperature gave superfluidity a concrete physical explanation.

Sources: [2][4][6]

Sources and reading notes

  1. 1962 award presentation: Landau’s liquid-helium theories

    Official contemporary account of collective excitations, neutron tests and second sound.

  2. 1978 award: low-temperature inventions and discoveries

    The low-temperature award context. Kapitsa’s Nobel lecture itself concerns plasma research.

  3. Kapitza: Viscosity of liquid helium below the lambda point (1938)

    Original narrow-gap viscosity report; subscription preview and bibliographic metadata are publicly readable.

  4. Nobel Prize in Physics 1978: official award

    Official attribution and award year. The observation or theoretical paper may be much earlier.

  5. Donnelly: The two-fluid theory and second sound in liquid helium (2009)

    Researcher’s account of Tisza and Landau, two-fluid response, second-sound transducers and experiments. A later review.

  6. Balibar: The discovery of superfluidity (2006 manuscript)

    Scholarly historical research comparing original reports and testimony. The account separates the contributions of Kapitza, Allen, Misener, London, Tisza and Landau.

  7. Allen and Misener: Flow of Liquid Helium II (1938)

    Independent capillary-flow report, published beside Kapitza’s letter. Its original preview and bibliographic record are public.

Keep reading

What this page links to directly

Condensed matter · Reading path

Cold liquids and superconducting order

  1. ArticleHow liquid helium opened the way to superconductivity
  2. ArticleHow Landau explained superfluid helium through its excitations
  3. You are hereWhy flow and oscillation reveal different responses in superfluid helium
  4. ArticleHow BCS pairing theory explains the superconducting gap
  5. ArticleHow tunneling current revealed the superconducting gap
  6. ArticleHow phase drives a supercurrent across a thin insulator
  7. ArticleHow an oxide ceramic opened high-temperature superconductivity
  8. ArticleHow a pressure anomaly revealed superfluid helium-three
  9. ArticleHow superconducting order varies through a material
  10. ArticleHow magnetic flux enters a superconductor as a vortex lattice
  11. ArticleWhat nuclear resonance revealed about pairing in helium-three
Something broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy