Coupled oscillators share normal modes. Combine two nearby frequencies to predict beats and compare the result with the motion of a spring chain.
Before you start: Chapter 1 on restoring force and angular frequency. Chapter 3 explains the difference between drive frequency and natural frequency.
After this chapter you can: Find the two normal frequencies of equal masses joined by a spring, calculate their beat period, and read the mode shapes in a longer chain.
A spring between two oscillators can take energy from one mass and pass it to the other. A displacement of just one mass sets up two normal modes. Each mode keeps its own energy in an ideal undamped system. Their frequencies differ, so the modes gradually go out of step. The motion can fade at one mass while growing at the other.
4.1 Find the motions that keep their shape
4.1.1 Two displacements stretch three springs
Put two masses m on a frictionless rail. Each mass connects to its nearest wall with a spring of stiffness k. A spring of stiffness kc joins the masses. Assume all three springs obey Hooke's law. Measure x1 and x2 from the masses' equilibria, with right positive for both. The change in the middle spring's length is x2−x1.
Apply Newton's second law to each mass. When the middle spring stretches, it pulls the left mass right and the right mass left:
In a normal mode, the displacement pattern stays proportional to one fixed shape. For this pair, either both masses have the same displacement, or one has the negative of the other's displacement. In the first case the middle spring keeps its length. In the second, the middle spring's change in length has twice the magnitude of either displacement.
Write the average and half-difference as q+ and q−. Adding the force equations removes the middle spring term. Subtracting the equations doubles that term in the relative motion.
A stronger middle spring raises the anti-phase frequency. It leaves the in-phase frequency unchanged because the spring has no change in length in that mode.
4.2 Release one mass and watch the beat
4.2.1 The two modes start together
Release the left mass from x1=A with the right mass at x2=0. Both start from rest. The two mode coordinates then start at A/2 and evolve as cosines at their own frequencies.
Let ωˉ=(ω++ω−)/2 and Δω=ω−−ω+. Adding and subtracting the cosines gives
When the coupling is weak, the second factors vary slowly. They set the envelopes of the fast oscillations. The left envelope first vanishes at t=π/Δω, when the right envelope first reaches A. The magnitudes of the envelopes repeat after 2π/Δω. At that point the fast oscillation usually has a different phase from the one at release.
4.2.2 Predict the first handoff
Take m=1.00kg, k=4.00N/m and kc=0.200N/m. The frequencies are ω+=2.000rad/s and ω−≈2.09762rad/s. Their difference is 0.09762rad/s, so the first envelope handoff is at about 32.2s. One full envelope cycle takes about 64.4s. The mass oscillates many times in that interval.
The envelopes describe displacement. The left mass can still have kinetic energy when its displacement envelope reaches zero, and the middle spring can still store energy. For weak coupling, the slow change of the envelopes tracks a near handoff of energy between the two sides.
The middle spring does work on the masses through equal and opposite forces. The power on each mass depends on its own velocity, so the powers need not cancel. Their sum equals the rate at which the middle spring loses potential energy. The total mechanical energy of the masses and springs stays constant.
4.3 Test mode shapes in a fixed-end chain
Open Coupled Oscillators and Normal Modes. This Lab uses identical springs and masses, including springs from the end beads to the fixed walls. Its time, displacement and energy are normalized.
4.3.1 Compare a pure mode with a local release
First choose Move together and set Moving beads to 3. All three beads move with the same sign, and the middle bead moves farther than its neighbors. The leading angular frequency is about 0.765. Then choose Opposite halves and set Moving beads back to 3. The end beads move in opposite directions at about 1.414, with the middle bead fixed. The two springs on the middle bead exert opposite forces that cancel throughout the motion.
Choose Release one bead, set Moving beads to 3 and leave Local release position at 50%. Predict which modes appear before opening Modal energy projected from the record. The initial displacement is mirror-symmetric about the middle, so its projection on mode 2, with opposite signs at the ends, is zero. Modes 1 and 3 can both contribute. Their end displacements cancel at release, then develop different phases.
4.3.2 Compare two probes in the same beat record
Choose Swelling and fading. This preset prepares a 12-bead chain with modes 11 and 12. For Probe position, use 27% to select bead 4 and 73% for bead 9. Move the probe without changing the preset. Compare the envelopes in Inspected bead trajectory. When the signals from the two modes nearly cancel at one bead, they add at the other.
Figure 4.1 Simulated displacements at beads 4 and 9 from the same 12-bead Swelling and fading release. The two beads are mirror images about the center of the chain. When either envelope is widest, the other is narrowest. They switch halfway through the beat cycle. Both panels use the same normalized displacement scale.
Table 4.1 The angular frequencies and energy shares of the two active modes in the simulated release.
Mode
Angular frequency
Share of total energy
11
1.94188
48.9%
12
1.98542
51.1%
The frequency difference predicts an envelope cycle of about 144.3 in normalized time. The beads' amplitudes switch from large to small or small to large about 72.2 into the record. Move the replay cursor and check that the two bars in the modal energy plot retain their heights as the bead motion changes.
4.4 Separate a mode's energy from a bead's energy
The decomposition is a way to solve the equations. Each mode carries a constant share of energy under the ideal model. A bead's displacement and velocity contain contributions from every excited mode. Adding those contributions can increase or decrease the bead's kinetic energy with time even when all the modal shares stay fixed.
A local energy report also needs a rule for shared springs. The Lab assigns half of each internal bond's potential energy to each of its neighboring beads, and all of a wall spring's potential energy to the bead it connects to. Adding the bead energies then recovers the total mechanical energy. A different assignment for shared springs can give different local values while preserving the same total.
The Lab's stiff and soft motions come from the shape of the chain's modes. Its springs all have unit stiffness. The slow beat in this preset comes from a small separation between two frequencies of the 12-bead chain. The two-mass example reaches a similar separation by choosing a weak coupling spring. In real systems, damping, a spread of component properties or a nonlinear spring law can change the size and timing of the handoff.
4.5 Exercises
In the two-mass system, both displacements are the same at all times. What change in length does the middle spring have? What fixes the oscillation frequency?
The left mass moves right by d and the right mass moves left by d. Find the force of the middle spring on the left mass. Use the shared right-positive coordinate.
Let kc tend to zero with m and k fixed. What happens to the frequency gap and the first handoff time? What moves in the uncoupled system when only the left mass is released?
A pair has normal angular frequencies 5.00rad/s and 5.25rad/s. Both masses start from rest with only the left one displaced. Find the first handoff time and the full envelope period.
In the three-bead Lab trial, why does a center-bead release from rest excite no mode 2?
Two modes have the same displacement amplitude in the same normalization and start from rest. Which carries more energy, the mode with the higher frequency or the one with the lower frequency?
At one instant in the two-mass model, both masses have zero displacement. Can the total energy be positive? Where would it be stored at that instant?
A fixed-end pair of 2.00kg masses has an in-phase angular frequency of 3.00rad/s and an anti-phase angular frequency of 4.00rad/s. Determine k and kc for the model in §4.1.
Exercise 1Show the answer
The change in length is zero because x2−x1=0. Only each wall spring supplies a restoring force. The in-phase angular frequency is k/m.
Exercise 2Show the answer
The signed change in length is (−d)−d=−2d. The middle spring is compressed and pushes the left mass left with signed force −2kcd.
Exercise 3Show the answer
The two frequencies approach the same value, so Δω goes to zero and π/Δω grows without bound. For exactly zero coupling the right mass stays at rest, and the left mass oscillates on its own wall spring.
Exercise 4Show the answer
The gap is 0.25rad/s. The first handoff takes π/Δω≈12.6s. The envelope period is twice that, about 25.1s.
Exercise 5Show the answer
Mode 2 has a node on the center bead. The other two beads start at equilibrium, and every bead starts from rest, so neither the displacement pattern nor the velocity pattern has a projection on mode 2.
Exercise 6Show the answer
The higher-frequency mode carries more energy. With the same normalization and the same amplitude, the modal energy at release is proportional to ω2. The higher-frequency coordinate has the larger restoring stiffness.
Exercise 7Show the answer
Yes. All springs have their equilibrium lengths then, so the energy can be in the motion of the masses. A single normal mode passes through such a state every half period.
Exercise 8Show the answer
The in-phase frequency gives k=mω+2=18.0N/m. The anti-phase frequency gives kc=m(ω−2−ω+2)/2=7.00N/m.
Test it in the Lab
Change one setting at a time, then compare what you see with the tables and answers in this chapter.