Skip to main content
Sandbox Physics
Kilonovae: heavy elements and diffusing light

From the energy equation to kilonova light curves and colours

Sandbox Physics ·

The bolometric light curve reaches its peak when the escaping luminosity catches up with the rate of deposited heating. A simple energy equation explains that crossing. Assume the expanding photosphere radiates like a blackbody, and the same luminosity gives a temperature and a set of filter magnitudes. An independent integration below checks the light curve.

Open the kilonova light-curve Lab

It builds on radioactive heat and the time light needs to escape merger debris. You need first-order differential equations and an integrating factor.

One energy equation

Treat one component as a uniform ball holding radiation energy EE. Three things change EE:

dEdt=Q(t)−Et−L(t).\frac{\mathrm dE}{\mathrm dt}=Q(t)-\frac{E}{t}-L(t).

QQ is the deposited radioactive power from the previous chapter. The term E/tE/t is the work the radiation does pushing the gas outward: for radiation, adiabatic expansion keeps ERER constant, and with R=vtR=vt that loss is E/tE/t. The last term is the light that leaks out. The random walk of the previous chapter says leakage takes a time proportional to 1/t1/t, so write

L=2ttd2 E,L=\frac{2t}{t_d^2}\,E ,

with the constant chosen so that tdt_d is Arnett's diffusion time, td=2κM/(βvc)t_d=\sqrt{2\kappa M/(\beta vc)} with β=13.4\beta=13.4. Villar and colleagues, §3

Solving it

Multiply the equation by tt and set X=EtX=Et. The adiabatic term disappears:

dXdt=tQ−2ttd2X.\frac{\mathrm dX}{\mathrm dt}=tQ-\frac{2t}{t_d^2}X .

This is linear. With the integrating factor et2/td2e^{t^2/t_d^2} and X(0)=0X(0)=0,

L(t)=2td2 e−t2/td2∫0tQ(t′) t′ et′2/td2 dt′.L(t)=\frac{2}{t_d^2}\,e^{-t^2/t_d^2}\int_0^t Q(t^\prime)\,t^\prime\,e^{t^{\prime2}/t_d^2}\,\mathrm dt^\prime .

This is Arnett's light curve. Early on the exponential factors are close to one and L≈(2/td2)∫0tQ t′ dt′L\approx(2/t_d^2)\int_0^t Q\,t^\prime\,\mathrm dt^\prime, small and rising. Late on, the Gaussian e−t2/td2e^{-t^2/t_d^2} forgets the early heat and LL approaches QQ.

A printed factor. Villar and colleagues print the kernel of this integral as t/tdt/t_d instead of 2t/td22t/t_d^2. Villar and colleagues, §3, eq. 3 The printed form has units of energy, not power, and equals our LL times td/2t_d/2. For the red component that factor is 3.683.68 if time is in days, so the printed formula cannot be used as it stands. The model restores 2/td2/t_d; the next sections give two independent checks that this is right.

Arnett's rule

Differentiate L=2X/td2L=2X/t_d^2 and use the equation for XX:

dLdt=2ttd2(Q−L).\frac{\mathrm dL}{\mathrm dt}=\frac{2t}{t_d^2}\bigl(Q-L\bigr).

The light curve is flat exactly where L=QL=Q. Before the peak L<QL<Q and heat is being stored; after it L>QL>Q and stored heat is released. This holds for each component separately. In the Lab's energy chart, each solid coloured curve peaks where it crosses the dashed line of its own colour.

Worked example 1. The red component peaks at 3.9983.998 days with L=1.120×1041 erg s−1L=1.120\times10^{41}\,\mathrm{erg\,s^{-1}}. By hand: q˙(4 d)=1.96×1010×4−1.3=3.23×109\dot q(4\,\mathrm d)=1.96\times10^{10}\times4^{-1.3}=3.23\times10^{9}, the thermalized fraction at four days is 0.3480.348, and M=9.94×1031 gM=9.94\times10^{31}\,\mathrm g, so Q=1.12×1041 erg s−1Q=1.12\times10^{41}\,\mathrm{erg\,s^{-1}}. The ratio L/QL/Q at the fitted peak is 0.999850.99985 for red and 0.999790.99979 for blue.

An independent check

The model computes LL with an exponential integrator for the integral above. To test it without reusing that code, check_independent_limits.py integrates the original equation for EE with SciPy's implicit Radau solver. Between 0.30.3 and 3030 days the two agree within 4.1×10−44.1\times10^{-4} for red and 4.3×10−44.3\times10^{-4} for blue.

The same script checks energy conservation: deposited energy equals radiated energy plus adiabatic work plus the energy left at the end, to 5×10−55\times10^{-5}. Only 1.61.6 percent of the deposited energy of the red component, and 3.23.2 percent of the blue, comes out as light. The rest is mostly heat deposited in the first hours, while the debris is still opaque, and spent on expansion.

The self-similar peak

For pure power-law heating, Q∝t−αQ\propto t^{-\alpha}, the peak time is a fixed fraction of tdt_d. Write x=tpeak/tdx=t_{\mathrm{peak}}/t_d and put L=QL=Q into the solution:

2e−x2∫0xu1−αeu2 du=x−α.2e^{-x^2}\int_0^x u^{1-\alpha}e^{u^2}\,\mathrm du=x^{-\alpha}.

For α=1.3\alpha=1.3, quadrature and root finding give x=0.7087x=0.7087. Running the model's own integrator with pure t−1.3t^{-1.3} heating at three opacities gives 0.708760.70876, 0.708750.70875 and 0.708740.70874, and a peak time growing as κ0.49999\kappa^{0.49999}.

With thermalization switched on the heating falls faster than t−1.3t^{-1.3}, so peaks come earlier: 3.9983.998 days for red instead of 0.709×7.36=5.220.709\times7.36=5.22, and 0.8230.823 days for blue instead of 1.001.00.

The photosphere and its floor

Each component is drawn as a blackbody sphere moving with the debris, R=vtR=vt. Stefan and Boltzmann's law fixes its temperature,

T=(L4πσSBR2)1/4.T=\left(\frac{L}{4\pi\sigma_{\mathrm{SB}}R^2}\right)^{1/4}.

Villar and colleagues add a floor, a behaviour also seen in more detailed simulations: once TT reaches TcT_c it stays there, and the radius shrinks to R=L/(4πσSBTc4)R=\sqrt{L/(4\pi\sigma_{\mathrm{SB}}T_c^4)}. They note that the floor may relate to the first ionization temperature of lanthanides. Villar and colleagues, §3, eqs. 4-5

Their printed equations put σSB2\sigma_{\mathrm{SB}}^2 inside the fourth root, while the receded radius uses σSB\sigma_{\mathrm{SB}}. With the square, every temperature would be divided by σSB1/4=0.0868\sigma_{\mathrm{SB}}^{1/4}=0.0868 in CGS units, so 4000 K4000\,\mathrm K would read as about 46000 K46000\,\mathrm K and the two branches would not meet at TcT_c. The model uses the dimensionally correct law; a numerical integral of the resulting spectrum over frequency returns LL to better than one part in 10610^6.

Table 2.1 The red photosphere of the Lab's default, floor 1151 K1151\,\mathrm K.
Day0.50.511223355771010
TT in K63386338498749873857385732603260253025302035203514921492

The red photosphere reaches its floor at 12.712.7 days. The blue one, with a floor of 3983 K3983\,\mathrm K, gets there at 1.861.86 days.

From a temperature to a magnitude

A sphere of radius RR at distance DD shows a flux density

Fν=πBν(T)(RD)2,mAB=−2.5log⁡10Fν−48.6,F_\nu=\pi B_\nu(T)\left(\frac{R}{D}\right)^2,\qquad m_{\mathrm{AB}}=-2.5\log_{10}F_\nu-48.6 ,

with FνF_\nu in erg s−1 cm−2 Hz−1\mathrm{erg\,s^{-1}\,cm^{-2}\,Hz^{-1}} and BνB_\nu the Planck function. Each filter is evaluated at its effective wavelength, and Milky Way extinction is then added: Aλ=RλE(B−V)A_\lambda=R_\lambda E(B-V) with Schlafly and Finkbeiner's coefficients for RV=3.1R_V=3.1. Schlafly and Finkbeiner, Table 6

Worked example 2. The blue component at one day has L=4.94×1041 erg s−1L=4.94\times10^{41}\,\mathrm{erg\,s^{-1}} and R=0.256c×1 d=6.63×1014 cmR=0.256c\times1\,\mathrm d=6.63\times10^{14}\,\mathrm{cm}, so T=6301 KT=6301\,\mathrm K. In the gg band, λ=4717\lambda=4717 Angstrom, hν/kT=4.84h\nu/kT=4.84 and Bν=3.01×10−5B_\nu=3.01\times10^{-5} in CGS. At D=39.5 Mpc=1.22×1026 cmD=39.5\,\mathrm{Mpc}=1.22\times10^{26}\,\mathrm{cm}, (R/D)2=2.96×10−23(R/D)^2=2.96\times10^{-23} and Fν=2.80×10−27F_\nu=2.80\times10^{-27}, giving mg=17.78m_g=17.78. The red component alone gives 20.3520.35; together they make 17.6817.68. Adding Ag=3.303×0.1228=0.41A_g=3.303\times0.1228=0.41 gives 18.0918.09, the value the Lab shows at one day.

The colour turns

The colour mg−mKm_g-m_K compares blue and infrared. A negative value means more blue light.

Table 2.2 Colour of the Lab's default, including extinction.
Day0.50.511223355771010
mg−mKm_g-m_K−0.88-0.880.080.082.182.182.842.844.414.415.355.355.645.64

Two effects add up. Each photosphere cools, moving its blackbody peak to longer wavelengths. And the hot blue component fades after its peak near day one, while the cooler red one is still rising.

Lab tasks

  1. Pause near the peak of the blue curve in the energy chart. Check that it touches the blue dashed line there, and that the red curve crosses the red dashed line near day four.
  2. Watch the red temperature readout. At what time does it stop falling? Compare with Table 2.1.
  3. Choose the lanthanide-poor preset and read the colour at five days. Explain the change from the default using the two effects above.

Exercises with explained answers

  1. Suppose the heating stops at time tst_s. How does LL fall afterwards?
  2. Show that L<QL<Q at all times before the first peak.
  3. The blue component peaks at 0.8230.823 days with L=5.06×1041 erg s−1L=5.06\times10^{41}\,\mathrm{erg\,s^{-1}}. What is its photosphere temperature then?
  4. If you kept σSB2\sigma_{\mathrm{SB}}^2 in the temperature law, would a fit to real data still find a reasonable floor temperature?
Answers
  1. With Q=0Q=0, dX/dt=−(2t/td2)X\mathrm dX/\mathrm dt=-(2t/t_d^2)X, so X∝e−t2/td2X\propto e^{-t^2/t_d^2} and L=2X/td2L=2X/t_d^2 falls as a Gaussian in time. Stored light drains on the timescale tdt_d, with no power-law tail.
  2. At t=0t=0, L=0L=0 and Q>0Q>0. While L<QL<Q, dL/dt>0\mathrm dL/\mathrm dt>0. The first time LL reaches QQ, dL/dt=0\mathrm dL/\mathrm dt=0, which is the first peak. So before it, L<QL<Q throughout.
  3. R=0.256×3.00×1010×0.823×86400=5.46×1014 cmR=0.256\times3.00\times10^{10}\times0.823\times86400=5.46\times10^{14}\,\mathrm{cm} and T=(L/(4πσSBR2))1/4≈7000 KT=(L/(4\pi\sigma_{\mathrm{SB}}R^2))^{1/4}\approx7000\,\mathrm K. That is still above the blue floor of 3983 K3983\,\mathrm K.
  4. No. The temperatures would come out about 11.511.5 times too high. A fit would push the luminosity or the radius far from physical values to compensate, and the floor would no longer join the free branch continuously.

Next, compare this model with the real GW170817 data and see which parameters the data pin down in fitting GW170817 and the trade-off between ejecta mass and speed.

Try it in the Lab

Pause near the peak of the white curve in the energy chart and check that it touches the dashed heating curve there. Open the kilonova light-curve Lab

Sources

  1. Villar and colleagues, §3
  2. Schlafly and Finkbeiner, Table 6

Keep reading

What this page links to directly

See this series on the content map →

Kilonovae: heavy elements and diffusing light · Reading path

From radioactive heat to a blue-then-red flash

  1. ArticleHow does a neutron-star collision turn nuclear decay into days of coloured light?
  2. ArticleRadioactive heat and the time light needs to escape merger debris
  3. You are hereFrom the energy equation to kilonova light curves and colours
  4. ArticleFitting GW170817 and the trade-off between ejecta mass and speed
  5. ArticleReproducing a two-component kilonova fit to the GW170817 photometry
  6. ArticleReading Tanaka et al. 2020 on r-process opacities in kilonovae
Something broken, confusing, or missing on this page?Tell us
What kind of feedback?

Sent with this page’s address, its Lab ID, the site language and your device type. Please leave out personal details. Feedback is kept for up to 12 months.Privacy policy